{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/102939"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/102939","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Design and Validation of Resorbable Vascular Grafts in Large Animals","abstract":"Prosthetic vascular grafts frequently occlude in small-diameter (< 6 mm) applications. Resorbable synthetic grafts might offer an economical way to produce living vessels for transplant instead. After implantation, these grafts are degraded by infiltrating host cells, which then build up a new, artery-like conduit in place of the foreign material. Previous work in the rat aorta demonstrated that resorbable grafts based on the fast-degrading elastomer poly(glycerol sebacate) (PGS) produced high-quality neoarteries with strong patency and native-like architecture. But those PGS-based grafts could not be produced at human sizes. In this dissertation, PGS-based grafts were developed using electrospinning, which is a more scalable and adaptable production method. The first graft prototype was tested in the mouse aorta. Grafts showed strong patency and mechanical stability, but the small pores in the electrospun PGS prevented timely degradation and neotissue formation. Therefore, a second prototype with larger pores was implanted in pigs as arteriovenous shunts. These grafts showed improved cell infiltration and early signs of remodeling. But the reinforcing composite sheath layer was kink-prone, and grafts eventually collapsed and thrombosed under compression from animal motion. Finally, a third prototype with large pores and improved kink resistance was implanted in the sheep carotid. These grafts showed extensive cellular infiltration and rapid degradation, leading to dilation and rupture. Though a successful prototype has not yet been achieved, we have now established a versatile and scalable fabrication process that can generate scaffolds with a range of degradation rates, from too slowly-degrading (mouse) to too quickly-degrading (sheep). Adjustments to scaffold design should locate the degradation rate matching the rate of neotissue formation somewhere in the middle.","abstract_html":"Prosthetic vascular grafts frequently occlude in small-diameter (&lt; 6 mm) applications. Resorbable synthetic grafts might offer an economical way to produce living vessels for transplant instead. After implantation, these grafts are degraded by infiltrating host cells, which then build up a new, artery-like conduit in place of the foreign material. Previous work in the rat aorta demonstrated that resorbable grafts based on the fast-degrading elastomer poly(glycerol sebacate) (PGS) produced high-quality neoarteries with strong patency and native-like architecture. But those PGS-based grafts could not be produced at human sizes. In this dissertation, PGS-based grafts were developed using electrospinning, which is a more scalable and adaptable production method. The first graft prototype was tested in the mouse aorta. Grafts showed strong patency and mechanical stability, but the small pores in the electrospun PGS prevented timely degradation and neotissue formation. Therefore, a second prototype with larger pores was implanted in pigs as arteriovenous shunts. These grafts showed improved cell infiltration and early signs of remodeling. But the reinforcing composite sheath layer was kink-prone, and grafts eventually collapsed and thrombosed under compression from animal motion. Finally, a third prototype with large pores and improved kink resistance was implanted in the sheep carotid. These grafts showed extensive cellular infiltration and rapid degradation, leading to dilation and rupture. Though a successful prototype has not yet been achieved, we have now established a versatile and scalable fabrication process that can generate scaffolds with a range of degradation rates, from too slowly-degrading (mouse) to too quickly-degrading (sheep). Adjustments to scaffold design should locate the degradation rate matching the rate of neotissue formation somewhere in the middle.","abstract_has_math":false,"creators":["Stowell, Chelsea"],"institution":"Cornell University","degree_name":"Ph. D., Biomedical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Wang, Yadong"],"committee_members":["Cheetham, Jonathan","Butcher, Jonathan T."],"year":2020,"date_issued":"2020-08","date_published":"2020-08","updated_at":"2026-11-19T03:08:32Z","subjects":["Biodegradation","Blood vessel prosthesis","Guided tissue regeneration","Inflammation","Poly(glycerol sebacate)","Porosity"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/4hhp-ns26"],"render_values":[{"text":"https://doi.org/10.7298/4hhp-ns26","href":"https://doi.org/10.7298/4hhp-ns26","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13277792"],"render_values":[{"text":"13277792","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12078","ProQuest Publication ID: 28023335"],"render_values":[{"text":"ProQuest Submission ID: 12078","href":null,"code":true},{"text":"ProQuest Publication ID: 28023335","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/102939","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/102939","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F102939","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Wang, Yadong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cheetham, Jonathan","Butcher, Jonathan T."]},{"key":"dc:creator","label":"Author","values":["Stowell, Chelsea"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-12T17:39:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-03-12T17:39:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-08"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://catalog.library.cornell.edu/catalog/13277792"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biodegradation","Blood vessel prosthesis","Guided tissue regeneration","Inflammation","Poly(glycerol sebacate)","Porosity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13277792"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/4hhp-ns26"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12078","ProQuest Publication ID: 28023335"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/102939"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c1e6a2ed-64bc-4cca-9a18-ca77b989e3e7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design and Validation of Resorbable Vascular Grafts in Large Animals</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-08</PublicationDate> <DOI>https://doi.org/10.7298/4hhp-ns26</DOI> <Authors> <Author> <DisplayName>Stowell, Chelsea</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Keyword>Biodegradation</Keyword> <Keyword>Blood vessel prosthesis</Keyword> <Keyword>Guided tissue regeneration</Keyword> <Keyword>Inflammation</Keyword> <Keyword>Poly(glycerol sebacate)</Keyword> <Keyword>Porosity</Keyword> <Abstract>Prosthetic vascular grafts frequently occlude in small-diameter (< 6 mm) applications. Resorbable synthetic grafts might offer an economical way to produce living vessels for transplant instead. After implantation, these grafts are degraded by infiltrating host cells, which then build up a new, artery-like conduit in place of the foreign material. Previous work in the rat aorta demonstrated that resorbable grafts based on the fast-degrading elastomer poly(glycerol sebacate) (PGS) produced high-quality neoarteries with strong patency and native-like architecture. But those PGS-based grafts could not be produced at human sizes. In this dissertation, PGS-based grafts were developed using electrospinning, which is a more scalable and adaptable production method. The first graft prototype was tested in the mouse aorta. Grafts showed strong patency and mechanical stability, but the small pores in the electrospun PGS prevented timely degradation and neotissue formation. Therefore, a second prototype with larger pores was implanted in pigs as arteriovenous shunts. These grafts showed improved cell infiltration and early signs of remodeling. But the reinforcing composite sheath layer was kink-prone, and grafts eventually collapsed and thrombosed under compression from animal motion. Finally, a third prototype with large pores and improved kink resistance was implanted in the sheep carotid. These grafts showed extensive cellular infiltration and rapid degradation, leading to dilation and rupture. Though a successful prototype has not yet been achieved, we have now established a versatile and scalable fabrication process that can generate scaffolds with a range of degradation rates, from too slowly-degrading (mouse) to too quickly-degrading (sheep). Adjustments to scaffold design should locate the degradation rate matching the rate of neotissue formation somewhere in the middle.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Stowell, Chelsea"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["145 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Prosthetic vascular grafts frequently occlude in small-diameter (< 6 mm) applications. Resorbable synthetic grafts might offer an economical way to produce living vessels for transplant instead. After implantation, these grafts are degraded by infiltrating host cells, which then build up a new, artery-like conduit in place of the foreign material. Previous work in the rat aorta demonstrated that resorbable grafts based on the fast-degrading elastomer poly(glycerol sebacate) (PGS) produced high-quality neoarteries with strong patency and native-like architecture. But those PGS-based grafts could not be produced at human sizes. In this dissertation, PGS-based grafts were developed using electrospinning, which is a more scalable and adaptable production method. The first graft prototype was tested in the mouse aorta. Grafts showed strong patency and mechanical stability, but the small pores in the electrospun PGS prevented timely degradation and neotissue formation. Therefore, a second prototype with larger pores was implanted in pigs as arteriovenous shunts. These grafts showed improved cell infiltration and early signs of remodeling. But the reinforcing composite sheath layer was kink-prone, and grafts eventually collapsed and thrombosed under compression from animal motion. Finally, a third prototype with large pores and improved kink resistance was implanted in the sheep carotid. These grafts showed extensive cellular infiltration and rapid degradation, leading to dilation and rupture. Though a successful prototype has not yet been achieved, we have now established a versatile and scalable fabrication process that can generate scaffolds with a range of degradation rates, from too slowly-degrading (mouse) to too quickly-degrading (sheep). Adjustments to scaffold design should locate the degradation rate matching the rate of neotissue formation somewhere in the middle."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Design and Validation of Resorbable Vascular Grafts in Large Animals"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c1e6a2ed-64bc-4cca-9a18-ca77b989e3e7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design and Validation of Resorbable Vascular Grafts in Large Animals</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-08</PublicationDate> <DOI>https://doi.org/10.7298/4hhp-ns26</DOI> <Authors> <Author> <DisplayName>Stowell, Chelsea</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Keyword>Biodegradation</Keyword> <Keyword>Blood vessel prosthesis</Keyword> <Keyword>Guided tissue regeneration</Keyword> <Keyword>Inflammation</Keyword> <Keyword>Poly(glycerol sebacate)</Keyword> <Keyword>Porosity</Keyword> <Abstract>Prosthetic vascular grafts frequently occlude in small-diameter (< 6 mm) applications. Resorbable synthetic grafts might offer an economical way to produce living vessels for transplant instead. After implantation, these grafts are degraded by infiltrating host cells, which then build up a new, artery-like conduit in place of the foreign material. Previous work in the rat aorta demonstrated that resorbable grafts based on the fast-degrading elastomer poly(glycerol sebacate) (PGS) produced high-quality neoarteries with strong patency and native-like architecture. But those PGS-based grafts could not be produced at human sizes. In this dissertation, PGS-based grafts were developed using electrospinning, which is a more scalable and adaptable production method. The first graft prototype was tested in the mouse aorta. Grafts showed strong patency and mechanical stability, but the small pores in the electrospun PGS prevented timely degradation and neotissue formation. Therefore, a second prototype with larger pores was implanted in pigs as arteriovenous shunts. These grafts showed improved cell infiltration and early signs of remodeling. But the reinforcing composite sheath layer was kink-prone, and grafts eventually collapsed and thrombosed under compression from animal motion. Finally, a third prototype with large pores and improved kink resistance was implanted in the sheep carotid. These grafts showed extensive cellular infiltration and rapid degradation, leading to dilation and rupture. Though a successful prototype has not yet been achieved, we have now established a versatile and scalable fabrication process that can generate scaffolds with a range of degradation rates, from too slowly-degrading (mouse) to too quickly-degrading (sheep). Adjustments to scaffold design should locate the degradation rate matching the rate of neotissue formation somewhere in the middle.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Stowell, Chelsea"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Wang, Yadong"],"dc:contributor.committeemember":["Cheetham, Jonathan","Butcher, Jonathan T."],"dc:creator":["Stowell, Chelsea"],"dc:date.accessioned":["2021-03-12T17:39:36Z"],"dc:date.available":["2021-03-12T17:39:36Z"],"dc:date.issued":["2020-08"],"dc:description":["145 pages"],"dc:description.abstract":["Prosthetic vascular grafts frequently occlude in small-diameter (< 6 mm) applications. Resorbable synthetic grafts might offer an economical way to produce living vessels for transplant instead. After implantation, these grafts are degraded by infiltrating host cells, which then build up a new, artery-like conduit in place of the foreign material. Previous work in the rat aorta demonstrated that resorbable grafts based on the fast-degrading elastomer poly(glycerol sebacate) (PGS) produced high-quality neoarteries with strong patency and native-like architecture. But those PGS-based grafts could not be produced at human sizes. In this dissertation, PGS-based grafts were developed using electrospinning, which is a more scalable and adaptable production method. The first graft prototype was tested in the mouse aorta. Grafts showed strong patency and mechanical stability, but the small pores in the electrospun PGS prevented timely degradation and neotissue formation. Therefore, a second prototype with larger pores was implanted in pigs as arteriovenous shunts. These grafts showed improved cell infiltration and early signs of remodeling. But the reinforcing composite sheath layer was kink-prone, and grafts eventually collapsed and thrombosed under compression from animal motion. Finally, a third prototype with large pores and improved kink resistance was implanted in the sheep carotid. These grafts showed extensive cellular infiltration and rapid degradation, leading to dilation and rupture. Though a successful prototype has not yet been achieved, we have now established a versatile and scalable fabrication process that can generate scaffolds with a range of degradation rates, from too slowly-degrading (mouse) to too quickly-degrading (sheep). Adjustments to scaffold design should locate the degradation rate matching the rate of neotissue formation somewhere in the middle."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["13277792"],"dc:identifier.doi":["https://doi.org/10.7298/4hhp-ns26"],"dc:identifier.other":["ProQuest Submission ID: 12078","ProQuest Publication ID: 28023335"],"dc:identifier.uri":["https://hdl.handle.net/1813/102939"],"dc:language.iso":["en"],"dc:relation.uri":["https://catalog.library.cornell.edu/catalog/13277792"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Biodegradation","Blood vessel prosthesis","Guided tissue regeneration","Inflammation","Poly(glycerol sebacate)","Porosity"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Design and Validation of Resorbable Vascular Grafts in Large Animals"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Biomedical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:08:32Z"}