{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/103012"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/103012","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"TECHNO-ECONOMIC ANALYSIS OF SEASONAL BOREHOLE THERMAL ENERGY STORAGE FOR HEATING APPLICATIONS","abstract":"Borehole Thermal Energy Storage (BTES) provides an innovative solution to utilize the subterraneous rock formations as a large thermal battery. The surplus thermal energy produced during the low demand periods is stored in the subsurface through shallow geothermal wells, and efficiently extracted throughout the peak demand months to provide space heating. In this study, a high-temperature BTES system is proposed to satisfy the daily winter heating demand of Snee Hall, Cornell University, Ithaca. The BTES is charged with overproduced summer steam (May to October) from Cornell’s Combined Heat and Power Plant and is subsequently harnessed (November to April) through an integrated heat pump (HP). To investigate the techno-economic feasibility of the project, a BTES + HP simulation tool was developed on Python 3.8.1 and validated. The tool simulates the 2-D transient heat transfer processes occurring in the rock structures and quantifies the key multi-year performance metrics (exit fluid temperature profile, the amount of energy stored/extracted, round-trip thermal efficiency and the COP of the heat pump) of the system. The technical performance of multiple BTES configurations was analyzed to optimize the BTES dimensions (number of boreholes, borehole spacing, borehole depth) for the site geological properties. The simulations indicate that an octagonal BTES array (90 m depth, 3 m spacing) with a 250 KW HT-heat pump can provide 94% of Snee Hall’s winter heating demand (COP-3.85, BTES efficiency-68.7%). The economic analysis reveals that proposed system has an NPV of $647,912 (year 30), IRR of 15%, and a payback period of 9 to 10 years. The system can offset up to 7349.45 MMBTU of natural gas combustion and save 273 MT CO2 emissions annually.","abstract_html":"Borehole Thermal Energy Storage (BTES) provides an innovative solution to utilize the subterraneous rock formations as a large thermal battery. The surplus thermal energy produced during the low demand periods is stored in the subsurface through shallow geothermal wells, and efficiently extracted throughout the peak demand months to provide space heating. In this study, a high-temperature BTES system is proposed to satisfy the daily winter heating demand of Snee Hall, Cornell University, Ithaca. The BTES is charged with overproduced summer steam (May to October) from Cornell’s Combined Heat and Power Plant and is subsequently harnessed (November to April) through an integrated heat pump (HP). To investigate the techno-economic feasibility of the project, a BTES + HP simulation tool was developed on Python 3.8.1 and validated. The tool simulates the 2-D transient heat transfer processes occurring in the rock structures and quantifies the key multi-year performance metrics (exit fluid temperature profile, the amount of energy stored/extracted, round-trip thermal efficiency and the COP of the heat pump) of the system. The technical performance of multiple BTES configurations was analyzed to optimize the BTES dimensions (number of boreholes, borehole spacing, borehole depth) for the site geological properties. The simulations indicate that an octagonal BTES array (90 m depth, 3 m spacing) with a 250 KW HT-heat pump can provide 94% of Snee Hall’s winter heating demand (COP-3.85, BTES efficiency-68.7%). The economic analysis reveals that proposed system has an NPV of $647,912 (year 30), IRR of 15%, and a payback period of 9 to 10 years. The system can offset up to 7349.45 MMBTU of natural gas combustion and save 273 MT CO2 emissions annually.","abstract_has_math":false,"creators":["Durga, Siddarth"],"institution":"Cornell University","degree_name":"M.S., Chemical Engineering","degree_level":"Master of Science","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Tester, Jefferson William"],"committee_members":["Zhang, K. Max","Cathles, Lawrence M."],"year":2020,"date_issued":"2020-08","date_published":"2020-08","updated_at":"2026-11-19T03:08:32Z","subjects":["Borehole Thermal Energy Storage","BTES","District Heating System","Energy Efficiency","Heat pump system","Renewable Heating"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/1cpq-t868"],"render_values":[{"text":"https://doi.org/10.7298/1cpq-t868","href":"https://doi.org/10.7298/1cpq-t868","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13277866"],"render_values":[{"text":"13277866","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10972","ProQuest Publication ID: 28026468"],"render_values":[{"text":"ProQuest Submission ID: 10972","href":null,"code":true},{"text":"ProQuest Publication ID: 28026468","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/103012","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/103012","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F103012","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Tester, Jefferson William"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zhang, K. Max","Cathles, Lawrence M."]},{"key":"dc:creator","label":"Author","values":["Durga, Siddarth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-12T17:40:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-08-27T06:00:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-08"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://catalog.library.cornell.edu/catalog/13277866"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Chemical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Borehole Thermal Energy Storage","BTES","District Heating System","Energy Efficiency","Heat pump system","Renewable Heating"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13277866"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/1cpq-t868"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10972","ProQuest Publication ID: 28026468"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/103012"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2c752151-854f-4ed4-bbc2-62b13f5a5c1d\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>TECHNO-ECONOMIC ANALYSIS OF SEASONAL BOREHOLE THERMAL ENERGY STORAGE FOR HEATING APPLICATIONS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-08</PublicationDate> <DOI>https://doi.org/10.7298/1cpq-t868</DOI> <Authors> <Author> <DisplayName>Durga, Siddarth</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Borehole Thermal Energy Storage</Keyword> <Keyword>BTES</Keyword> <Keyword>District Heating System</Keyword> <Keyword>Energy Efficiency</Keyword> <Keyword>Heat pump system</Keyword> <Keyword>Renewable Heating</Keyword> <Abstract>Borehole Thermal Energy Storage (BTES) provides an innovative solution to utilize the subterraneous rock formations as a large thermal battery. The surplus thermal energy produced during the low demand periods is stored in the subsurface through shallow geothermal wells, and efficiently extracted throughout the peak demand months to provide space heating. In this study, a high-temperature BTES system is proposed to satisfy the daily winter heating demand of Snee Hall, Cornell University, Ithaca. The BTES is charged with overproduced summer steam (May to October) from Cornell’s Combined Heat and Power Plant and is subsequently harnessed (November to April) through an integrated heat pump (HP). To investigate the techno-economic feasibility of the project, a BTES + HP simulation tool was developed on Python 3.8.1 and validated. The tool simulates the 2-D transient heat transfer processes occurring in the rock structures and quantifies the key multi-year performance metrics (exit fluid temperature profile, the amount of energy stored/extracted, round-trip thermal efficiency and the COP of the heat pump) of the system. The technical performance of multiple BTES configurations was analyzed to optimize the BTES dimensions (number of boreholes, borehole spacing, borehole depth) for the site geological properties. The simulations indicate that an octagonal BTES array (90 m depth, 3 m spacing) with a 250 KW HT-heat pump can provide 94% of Snee Hall’s winter heating demand (COP-3.85, BTES efficiency-68.7%). The economic analysis reveals that proposed system has an NPV of $647,912 (year 30), IRR of 15%, and a payback period of 9 to 10 years. The system can offset up to 7349.45 MMBTU of natural gas combustion and save 273 MT CO2 emissions annually.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Durga, Siddarth"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["112 pages","Supplemental file(s) description: BTES Simulation."]},{"key":"dc:description.abstract","label":"Abstract","values":["Borehole Thermal Energy Storage (BTES) provides an innovative solution to utilize the subterraneous rock formations as a large thermal battery. The surplus thermal energy produced during the low demand periods is stored in the subsurface through shallow geothermal wells, and efficiently extracted throughout the peak demand months to provide space heating. In this study, a high-temperature BTES system is proposed to satisfy the daily winter heating demand of Snee Hall, Cornell University, Ithaca. The BTES is charged with overproduced summer steam (May to October) from Cornell’s Combined Heat and Power Plant and is subsequently harnessed (November to April) through an integrated heat pump (HP). To investigate the techno-economic feasibility of the project, a BTES + HP simulation tool was developed on Python 3.8.1 and validated. The tool simulates the 2-D transient heat transfer processes occurring in the rock structures and quantifies the key multi-year performance metrics (exit fluid temperature profile, the amount of energy stored/extracted, round-trip thermal efficiency and the COP of the heat pump) of the system. The technical performance of multiple BTES configurations was analyzed to optimize the BTES dimensions (number of boreholes, borehole spacing, borehole depth) for the site geological properties. The simulations indicate that an octagonal BTES array (90 m depth, 3 m spacing) with a 250 KW HT-heat pump can provide 94% of Snee Hall’s winter heating demand (COP-3.85, BTES efficiency-68.7%). The economic analysis reveals that proposed system has an NPV of $647,912 (year 30), IRR of 15%, and a payback period of 9 to 10 years. The system can offset up to 7349.45 MMBTU of natural gas combustion and save 273 MT CO2 emissions annually."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","video/quicktime"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["TECHNO-ECONOMIC ANALYSIS OF SEASONAL BOREHOLE THERMAL ENERGY STORAGE FOR HEATING APPLICATIONS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2c752151-854f-4ed4-bbc2-62b13f5a5c1d\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>TECHNO-ECONOMIC ANALYSIS OF SEASONAL BOREHOLE THERMAL ENERGY STORAGE FOR HEATING APPLICATIONS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-08</PublicationDate> <DOI>https://doi.org/10.7298/1cpq-t868</DOI> <Authors> <Author> <DisplayName>Durga, Siddarth</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Borehole Thermal Energy Storage</Keyword> <Keyword>BTES</Keyword> <Keyword>District Heating System</Keyword> <Keyword>Energy Efficiency</Keyword> <Keyword>Heat pump system</Keyword> <Keyword>Renewable Heating</Keyword> <Abstract>Borehole Thermal Energy Storage (BTES) provides an innovative solution to utilize the subterraneous rock formations as a large thermal battery. The surplus thermal energy produced during the low demand periods is stored in the subsurface through shallow geothermal wells, and efficiently extracted throughout the peak demand months to provide space heating. In this study, a high-temperature BTES system is proposed to satisfy the daily winter heating demand of Snee Hall, Cornell University, Ithaca. The BTES is charged with overproduced summer steam (May to October) from Cornell’s Combined Heat and Power Plant and is subsequently harnessed (November to April) through an integrated heat pump (HP). To investigate the techno-economic feasibility of the project, a BTES + HP simulation tool was developed on Python 3.8.1 and validated. The tool simulates the 2-D transient heat transfer processes occurring in the rock structures and quantifies the key multi-year performance metrics (exit fluid temperature profile, the amount of energy stored/extracted, round-trip thermal efficiency and the COP of the heat pump) of the system. The technical performance of multiple BTES configurations was analyzed to optimize the BTES dimensions (number of boreholes, borehole spacing, borehole depth) for the site geological properties. The simulations indicate that an octagonal BTES array (90 m depth, 3 m spacing) with a 250 KW HT-heat pump can provide 94% of Snee Hall’s winter heating demand (COP-3.85, BTES efficiency-68.7%). The economic analysis reveals that proposed system has an NPV of $647,912 (year 30), IRR of 15%, and a payback period of 9 to 10 years. The system can offset up to 7349.45 MMBTU of natural gas combustion and save 273 MT CO2 emissions annually.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Durga, Siddarth"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Tester, Jefferson William"],"dc:contributor.committeemember":["Zhang, K. Max","Cathles, Lawrence M."],"dc:creator":["Durga, Siddarth"],"dc:date.accessioned":["2021-03-12T17:40:49Z"],"dc:date.available":["2021-08-27T06:00:21Z"],"dc:date.issued":["2020-08"],"dc:description":["112 pages","Supplemental file(s) description: BTES Simulation."],"dc:description.abstract":["Borehole Thermal Energy Storage (BTES) provides an innovative solution to utilize the subterraneous rock formations as a large thermal battery. The surplus thermal energy produced during the low demand periods is stored in the subsurface through shallow geothermal wells, and efficiently extracted throughout the peak demand months to provide space heating. In this study, a high-temperature BTES system is proposed to satisfy the daily winter heating demand of Snee Hall, Cornell University, Ithaca. The BTES is charged with overproduced summer steam (May to October) from Cornell’s Combined Heat and Power Plant and is subsequently harnessed (November to April) through an integrated heat pump (HP). To investigate the techno-economic feasibility of the project, a BTES + HP simulation tool was developed on Python 3.8.1 and validated. The tool simulates the 2-D transient heat transfer processes occurring in the rock structures and quantifies the key multi-year performance metrics (exit fluid temperature profile, the amount of energy stored/extracted, round-trip thermal efficiency and the COP of the heat pump) of the system. The technical performance of multiple BTES configurations was analyzed to optimize the BTES dimensions (number of boreholes, borehole spacing, borehole depth) for the site geological properties. The simulations indicate that an octagonal BTES array (90 m depth, 3 m spacing) with a 250 KW HT-heat pump can provide 94% of Snee Hall’s winter heating demand (COP-3.85, BTES efficiency-68.7%). The economic analysis reveals that proposed system has an NPV of $647,912 (year 30), IRR of 15%, and a payback period of 9 to 10 years. The system can offset up to 7349.45 MMBTU of natural gas combustion and save 273 MT CO2 emissions annually."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf","video/quicktime"],"dc:identifier.bibid":["13277866"],"dc:identifier.doi":["https://doi.org/10.7298/1cpq-t868"],"dc:identifier.other":["ProQuest Submission ID: 10972","ProQuest Publication ID: 28026468"],"dc:identifier.uri":["https://hdl.handle.net/1813/103012"],"dc:language.iso":["en"],"dc:relation.uri":["https://catalog.library.cornell.edu/catalog/13277866"],"dc:subject":["Borehole Thermal Energy Storage","BTES","District Heating System","Energy Efficiency","Heat pump system","Renewable Heating"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["TECHNO-ECONOMIC ANALYSIS OF SEASONAL BOREHOLE THERMAL ENERGY STORAGE FOR HEATING APPLICATIONS"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Chemical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:08:32Z"}