{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/103093"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/103093","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"High sensitivity magnet-tipped cantilevers and micrometer-scale coplanar waveguides to enable nanoscale magnetic resonance imaging","abstract":"Magnetic resonance force microscopy (MRFM) is a scanned probe technique that detects spin magnetization as a force or force gradient exerted between a magnet-tipped micro-cantilever and nuclear or electron spins in a thin-film sample in vacuum at cryogenic temperatures. By detecting magnetic resonance mechanically, MRFM combines the sensitivity of scanning probe microscopy with the isotopic specificity of magnetic resonance. To further increase sensitivity and achieve high-resolution single molecule magnetic resonance imaging, highly polarized nuclear spins can be created via dynamic nuclear polarization. In this thesis, we discuss the fabrication of high-sensitivity cantilevers with integrated nano-magnets and micrometer-scale coplanar waveguides operating from dc to 40 GHz. These technical advancements enable two exciting experiments: (1) the measurement of electric field and field gradient noise over a metal at nanoscale distances over a broad temperature range and (2) the first achievement of microwave-induced nuclear spin hyperpolarization in a nanoscale magnetic resonance experiment. First, we report our efforts to reproduce a batch and-serial fabrication protocol of high-gradient nanomagnets on cantilevers for scanned probe detection. We then extend the electron-beam lithography-based protocol to fabricate 50 nm wide cobalt nanomagnets suitable for use in a magnetic resonance force microscope. The anticipated factor of four increase in tip-field gradient as a result of size reduction is expected to translate into a 256-fold reduction in acquisition time in the polarized-spin limit. Second, we study non-contact friction experienced by a magnet-tipped cantilever near a metal surface at room temperature and 77 K. We study cantilever surface dissipation and frequency noise as a function of temperature, tip-sample separation, the composition of the conductive surface, and the applied tip-bias voltage. We find that the force noise follows a power law as a function of tip-sample separation and is mainly independent of the metal surfaces studied here. Finally, we design, fabricate, and characterize micron-scale coplanar waveguides that are then coupled to a 36 GHz chip-scale CMOS microwave source. We report the successful operation of the chip-scale 36 GHz source in vacuum at temperatures down to 12 K. This finding is a promising prospect for using the microwave source to excite electron spin resonance and initiate DNP in an individual biomolecule with an attached nitroxide spin label. Overall, the work described in this thesis opens up new avenues for pushing magnetic resonance imaging to nanometer resolution, where single molecule imaging becomes more feasible.","abstract_html":"Magnetic resonance force microscopy (MRFM) is a scanned probe technique that detects spin magnetization as a force or force gradient exerted between a magnet-tipped micro-cantilever and nuclear or electron spins in a thin-film sample in vacuum at cryogenic temperatures. By detecting magnetic resonance mechanically, MRFM combines the sensitivity of scanning probe microscopy with the isotopic specificity of magnetic resonance. To further increase sensitivity and achieve high-resolution single molecule magnetic resonance imaging, highly polarized nuclear spins can be created via dynamic nuclear polarization. In this thesis, we discuss the fabrication of high-sensitivity cantilevers with integrated nano-magnets and micrometer-scale coplanar waveguides operating from dc to 40 GHz. These technical advancements enable two exciting experiments: (1) the measurement of electric field and field gradient noise over a metal at nanoscale distances over a broad temperature range and (2) the first achievement of microwave-induced nuclear spin hyperpolarization in a nanoscale magnetic resonance experiment. First, we report our efforts to reproduce a batch and-serial fabrication protocol of high-gradient nanomagnets on cantilevers for scanned probe detection. We then extend the electron-beam lithography-based protocol to fabricate 50 nm wide cobalt nanomagnets suitable for use in a magnetic resonance force microscope. The anticipated factor of four increase in tip-field gradient as a result of size reduction is expected to translate into a 256-fold reduction in acquisition time in the polarized-spin limit. Second, we study non-contact friction experienced by a magnet-tipped cantilever near a metal surface at room temperature and 77 K. We study cantilever surface dissipation and frequency noise as a function of temperature, tip-sample separation, the composition of the conductive surface, and the applied tip-bias voltage. We find that the force noise follows a power law as a function of tip-sample separation and is mainly independent of the metal surfaces studied here. Finally, we design, fabricate, and characterize micron-scale coplanar waveguides that are then coupled to a 36 GHz chip-scale CMOS microwave source. We report the successful operation of the chip-scale 36 GHz source in vacuum at temperatures down to 12 K. This finding is a promising prospect for using the microwave source to excite electron spin resonance and initiate DNP in an individual biomolecule with an attached nitroxide spin label. Overall, the work described in this thesis opens up new avenues for pushing magnetic resonance imaging to nanometer resolution, where single molecule imaging becomes more feasible.","abstract_has_math":false,"creators":["Nasr, Pamela"],"institution":"Cornell University","degree_name":"Ph. D., Chemistry and Chemical Biology","degree_level":"Doctor of Philosophy","degree_discipline":"Chemistry and Chemical Biology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Marohn, John A."],"committee_members":["Crane, Brian","Ezra, Greg","Ralph, Dan"],"year":2020,"date_issued":"2020-08","date_published":"2020-08","updated_at":"2026-11-19T03:08:32Z","subjects":["Cantilevers","Coplanar waveguides","Electric field noise","Magnetic resonance","Scanning probe"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/gk0v-7d05"],"render_values":[{"text":"https://doi.org/10.7298/gk0v-7d05","href":"https://doi.org/10.7298/gk0v-7d05","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13277871"],"render_values":[{"text":"13277871","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11299","ProQuest Publication ID: 13806681"],"render_values":[{"text":"ProQuest Submission ID: 11299","href":null,"code":true},{"text":"ProQuest Publication ID: 13806681","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/103093","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/103093","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F103093","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Marohn, John A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Crane, Brian","Ezra, Greg","Ralph, Dan"]},{"key":"dc:creator","label":"Author","values":["Nasr, Pamela"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-12T17:42:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-03-12T17:42:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-08"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://catalog.library.cornell.edu/catalog/13277871"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry and Chemical Biology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Chemistry and Chemical Biology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cantilevers","Coplanar waveguides","Electric field noise","Magnetic resonance","Scanning probe"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13277871"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/gk0v-7d05"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11299","ProQuest Publication ID: 13806681"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/103093"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3194f4ce-1596-49b3-b118-c0756f9d94e0\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>High sensitivity magnet-tipped cantilevers and micrometer-scale coplanar waveguides to enable nanoscale magnetic resonance imaging</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-08</PublicationDate> <DOI>https://doi.org/10.7298/gk0v-7d05</DOI> <Authors> <Author> <DisplayName>Nasr, Pamela</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Cantilevers</Keyword> <Keyword>Coplanar waveguides</Keyword> <Keyword>Electric field noise</Keyword> <Keyword>Magnetic resonance</Keyword> <Keyword>Scanning probe</Keyword> <Abstract>Magnetic resonance force microscopy (MRFM) is a scanned probe technique that detects spin magnetization as a force or force gradient exerted between a magnet-tipped micro-cantilever and nuclear or electron spins in a thin-film sample in vacuum at cryogenic temperatures. By detecting magnetic resonance mechanically, MRFM combines the sensitivity of scanning probe microscopy with the isotopic specificity of magnetic resonance. To further increase sensitivity and achieve high-resolution single molecule magnetic resonance imaging, highly polarized nuclear spins can be created via dynamic nuclear polarization. In this thesis, we discuss the fabrication of high-sensitivity cantilevers with integrated nano-magnets and micrometer-scale coplanar waveguides operating from dc to 40 GHz. These technical advancements enable two exciting experiments: (1) the measurement of electric field and field gradient noise over a metal at nanoscale distances over a broad temperature range and (2) the first achievement of microwave-induced nuclear spin hyperpolarization in a nanoscale magnetic resonance experiment. First, we report our efforts to reproduce a batch and-serial fabrication protocol of high-gradient nanomagnets on cantilevers for scanned probe detection. We then extend the electron-beam lithography-based protocol to fabricate 50 nm wide cobalt nanomagnets suitable for use in a magnetic resonance force microscope. The anticipated factor of four increase in tip-field gradient as a result of size reduction is expected to translate into a 256-fold reduction in acquisition time in the polarized-spin limit. Second, we study non-contact friction experienced by a magnet-tipped cantilever near a metal surface at room temperature and 77 K. We study cantilever surface dissipation and frequency noise as a function of temperature, tip-sample separation, the composition of the conductive surface, and the applied tip-bias voltage. We find that the force noise follows a power law as a function of tip-sample separation and is mainly independent of the metal surfaces studied here. Finally, we design, fabricate, and characterize micron-scale coplanar waveguides that are then coupled to a 36 GHz chip-scale CMOS microwave source. We report the successful operation of the chip-scale 36 GHz source in vacuum at temperatures down to 12 K. This finding is a promising prospect for using the microwave source to excite electron spin resonance and initiate DNP in an individual biomolecule with an attached nitroxide spin label. Overall, the work described in this thesis opens up new avenues for pushing magnetic resonance imaging to nanometer resolution, where single molecule imaging becomes more feasible.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Nasr, Pamela"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["131 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance force microscopy (MRFM) is a scanned probe technique that detects spin magnetization as a force or force gradient exerted between a magnet-tipped micro-cantilever and nuclear or electron spins in a thin-film sample in vacuum at cryogenic temperatures. By detecting magnetic resonance mechanically, MRFM combines the sensitivity of scanning probe microscopy with the isotopic specificity of magnetic resonance. To further increase sensitivity and achieve high-resolution single molecule magnetic resonance imaging, highly polarized nuclear spins can be created via dynamic nuclear polarization. In this thesis, we discuss the fabrication of high-sensitivity cantilevers with integrated nano-magnets and micrometer-scale coplanar waveguides operating from dc to 40 GHz. These technical advancements enable two exciting experiments: (1) the measurement of electric field and field gradient noise over a metal at nanoscale distances over a broad temperature range and (2) the first achievement of microwave-induced nuclear spin hyperpolarization in a nanoscale magnetic resonance experiment. First, we report our efforts to reproduce a batch and-serial fabrication protocol of high-gradient nanomagnets on cantilevers for scanned probe detection. We then extend the electron-beam lithography-based protocol to fabricate 50 nm wide cobalt nanomagnets suitable for use in a magnetic resonance force microscope. The anticipated factor of four increase in tip-field gradient as a result of size reduction is expected to translate into a 256-fold reduction in acquisition time in the polarized-spin limit. Second, we study non-contact friction experienced by a magnet-tipped cantilever near a metal surface at room temperature and 77 K. We study cantilever surface dissipation and frequency noise as a function of temperature, tip-sample separation, the composition of the conductive surface, and the applied tip-bias voltage. We find that the force noise follows a power law as a function of tip-sample separation and is mainly independent of the metal surfaces studied here. Finally, we design, fabricate, and characterize micron-scale coplanar waveguides that are then coupled to a 36 GHz chip-scale CMOS microwave source. We report the successful operation of the chip-scale 36 GHz source in vacuum at temperatures down to 12 K. This finding is a promising prospect for using the microwave source to excite electron spin resonance and initiate DNP in an individual biomolecule with an attached nitroxide spin label. Overall, the work described in this thesis opens up new avenues for pushing magnetic resonance imaging to nanometer resolution, where single molecule imaging becomes more feasible."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["High sensitivity magnet-tipped cantilevers and micrometer-scale coplanar waveguides to enable nanoscale magnetic resonance imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3194f4ce-1596-49b3-b118-c0756f9d94e0\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>High sensitivity magnet-tipped cantilevers and micrometer-scale coplanar waveguides to enable nanoscale magnetic resonance imaging</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-08</PublicationDate> <DOI>https://doi.org/10.7298/gk0v-7d05</DOI> <Authors> <Author> <DisplayName>Nasr, Pamela</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Cantilevers</Keyword> <Keyword>Coplanar waveguides</Keyword> <Keyword>Electric field noise</Keyword> <Keyword>Magnetic resonance</Keyword> <Keyword>Scanning probe</Keyword> <Abstract>Magnetic resonance force microscopy (MRFM) is a scanned probe technique that detects spin magnetization as a force or force gradient exerted between a magnet-tipped micro-cantilever and nuclear or electron spins in a thin-film sample in vacuum at cryogenic temperatures. By detecting magnetic resonance mechanically, MRFM combines the sensitivity of scanning probe microscopy with the isotopic specificity of magnetic resonance. To further increase sensitivity and achieve high-resolution single molecule magnetic resonance imaging, highly polarized nuclear spins can be created via dynamic nuclear polarization. In this thesis, we discuss the fabrication of high-sensitivity cantilevers with integrated nano-magnets and micrometer-scale coplanar waveguides operating from dc to 40 GHz. These technical advancements enable two exciting experiments: (1) the measurement of electric field and field gradient noise over a metal at nanoscale distances over a broad temperature range and (2) the first achievement of microwave-induced nuclear spin hyperpolarization in a nanoscale magnetic resonance experiment. First, we report our efforts to reproduce a batch and-serial fabrication protocol of high-gradient nanomagnets on cantilevers for scanned probe detection. We then extend the electron-beam lithography-based protocol to fabricate 50 nm wide cobalt nanomagnets suitable for use in a magnetic resonance force microscope. The anticipated factor of four increase in tip-field gradient as a result of size reduction is expected to translate into a 256-fold reduction in acquisition time in the polarized-spin limit. Second, we study non-contact friction experienced by a magnet-tipped cantilever near a metal surface at room temperature and 77 K. We study cantilever surface dissipation and frequency noise as a function of temperature, tip-sample separation, the composition of the conductive surface, and the applied tip-bias voltage. We find that the force noise follows a power law as a function of tip-sample separation and is mainly independent of the metal surfaces studied here. Finally, we design, fabricate, and characterize micron-scale coplanar waveguides that are then coupled to a 36 GHz chip-scale CMOS microwave source. We report the successful operation of the chip-scale 36 GHz source in vacuum at temperatures down to 12 K. This finding is a promising prospect for using the microwave source to excite electron spin resonance and initiate DNP in an individual biomolecule with an attached nitroxide spin label. Overall, the work described in this thesis opens up new avenues for pushing magnetic resonance imaging to nanometer resolution, where single molecule imaging becomes more feasible.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Nasr, Pamela"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Marohn, John A."],"dc:contributor.committeemember":["Crane, Brian","Ezra, Greg","Ralph, Dan"],"dc:creator":["Nasr, Pamela"],"dc:date.accessioned":["2021-03-12T17:42:58Z"],"dc:date.available":["2021-03-12T17:42:58Z"],"dc:date.issued":["2020-08"],"dc:description":["131 pages"],"dc:description.abstract":["Magnetic resonance force microscopy (MRFM) is a scanned probe technique that detects spin magnetization as a force or force gradient exerted between a magnet-tipped micro-cantilever and nuclear or electron spins in a thin-film sample in vacuum at cryogenic temperatures. By detecting magnetic resonance mechanically, MRFM combines the sensitivity of scanning probe microscopy with the isotopic specificity of magnetic resonance. To further increase sensitivity and achieve high-resolution single molecule magnetic resonance imaging, highly polarized nuclear spins can be created via dynamic nuclear polarization. In this thesis, we discuss the fabrication of high-sensitivity cantilevers with integrated nano-magnets and micrometer-scale coplanar waveguides operating from dc to 40 GHz. These technical advancements enable two exciting experiments: (1) the measurement of electric field and field gradient noise over a metal at nanoscale distances over a broad temperature range and (2) the first achievement of microwave-induced nuclear spin hyperpolarization in a nanoscale magnetic resonance experiment. First, we report our efforts to reproduce a batch and-serial fabrication protocol of high-gradient nanomagnets on cantilevers for scanned probe detection. We then extend the electron-beam lithography-based protocol to fabricate 50 nm wide cobalt nanomagnets suitable for use in a magnetic resonance force microscope. The anticipated factor of four increase in tip-field gradient as a result of size reduction is expected to translate into a 256-fold reduction in acquisition time in the polarized-spin limit. Second, we study non-contact friction experienced by a magnet-tipped cantilever near a metal surface at room temperature and 77 K. We study cantilever surface dissipation and frequency noise as a function of temperature, tip-sample separation, the composition of the conductive surface, and the applied tip-bias voltage. We find that the force noise follows a power law as a function of tip-sample separation and is mainly independent of the metal surfaces studied here. Finally, we design, fabricate, and characterize micron-scale coplanar waveguides that are then coupled to a 36 GHz chip-scale CMOS microwave source. We report the successful operation of the chip-scale 36 GHz source in vacuum at temperatures down to 12 K. This finding is a promising prospect for using the microwave source to excite electron spin resonance and initiate DNP in an individual biomolecule with an attached nitroxide spin label. Overall, the work described in this thesis opens up new avenues for pushing magnetic resonance imaging to nanometer resolution, where single molecule imaging becomes more feasible."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["13277871"],"dc:identifier.doi":["https://doi.org/10.7298/gk0v-7d05"],"dc:identifier.other":["ProQuest Submission ID: 11299","ProQuest Publication ID: 13806681"],"dc:identifier.uri":["https://hdl.handle.net/1813/103093"],"dc:language.iso":["en"],"dc:relation.uri":["https://catalog.library.cornell.edu/catalog/13277871"],"dc:subject":["Cantilevers","Coplanar waveguides","Electric field noise","Magnetic resonance","Scanning probe"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["High sensitivity magnet-tipped cantilevers and micrometer-scale coplanar waveguides to enable nanoscale magnetic resonance imaging"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry and Chemical Biology"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Chemistry and Chemical Biology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:08:32Z"}