{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/109678"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/109678","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Rapid Analysis of Cheddar Cheese and Nonfat Dry Milk Using Mid Infrared Spectroscopy","abstract":"The first objective of this work was to develop methods for the creation of liquid Cheddar cheese calibration standards and evaluate the calibration set using a combination MIR transmittance analysis and an in-line conductivity sensor within the MIR milk analyzer for measuring fat, protein, moisture, and salt content. Annatto colored cheese samples were collected from one cheese factory. Each cheese sample was analyzed using reference chemistry and then blended into a particle free dispersion to run through the FT-MIR. The remaining cheese was combined and used to create an 8-sample calibration set with decreasing amounts of fat, protein, total solids, and salt. Validation samples were also run using the new calibration model. Standard error of prediction (SEP) values for fat, moisture, and salt of the validation samples on the MIR produced SEP values for fat A+B, moisture, and salt of 0.177, 0.176, and 0.022, respectively. These low SEP values indicate that MIR could be used as an effective alternative to cheese producers for the rapid analysis of cheese using equipment most dairy processors already have in their facility. Our second objective was to develop and evaluate the performance of the rapid determination of fat, protein, lactose, and moisture of nonfat dry milk powders using mid-infrared transmittance analysis. Nonfat dry milk powders were reconstituted and analyzed using reference chemistry and the FT-MIR to create a calibration model. Validation was done at a separate time using the same nonfat dry milk powders. The SEP values for the validation samples were low. Moisture, fat A, protein, and lactose had SEP values of 0.292, 0.023, 0.110, and 0.334, respectively. This indicates that MIR could be used as an easy and effective way for NFDM producers to measure the components of their product.","abstract_html":"The first objective of this work was to develop methods for the creation of liquid Cheddar cheese calibration standards and evaluate the calibration set using a combination MIR transmittance analysis and an in-line conductivity sensor within the MIR milk analyzer for measuring fat, protein, moisture, and salt content. Annatto colored cheese samples were collected from one cheese factory. Each cheese sample was analyzed using reference chemistry and then blended into a particle free dispersion to run through the FT-MIR. The remaining cheese was combined and used to create an 8-sample calibration set with decreasing amounts of fat, protein, total solids, and salt. Validation samples were also run using the new calibration model. Standard error of prediction (SEP) values for fat, moisture, and salt of the validation samples on the MIR produced SEP values for fat A+B, moisture, and salt of 0.177, 0.176, and 0.022, respectively. These low SEP values indicate that MIR could be used as an effective alternative to cheese producers for the rapid analysis of cheese using equipment most dairy processors already have in their facility. Our second objective was to develop and evaluate the performance of the rapid determination of fat, protein, lactose, and moisture of nonfat dry milk powders using mid-infrared transmittance analysis. Nonfat dry milk powders were reconstituted and analyzed using reference chemistry and the FT-MIR to create a calibration model. Validation was done at a separate time using the same nonfat dry milk powders. The SEP values for the validation samples were low. Moisture, fat A, protein, and lactose had SEP values of 0.292, 0.023, 0.110, and 0.334, respectively. This indicates that MIR could be used as an easy and effective way for NFDM producers to measure the components of their product.","abstract_has_math":false,"creators":["Peterson, Emmalee"],"institution":"Cornell University","degree_name":"M.S., Food Science and Technology","degree_level":"Master of Science","degree_discipline":"Food Science and Technology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Barbano, David Mark"],"committee_members":["Novakovic, Andrew Milovan"],"year":2021,"date_issued":"2021-05","date_published":"2021-05","updated_at":"2026-11-19T03:08:55Z","subjects":["Mid infrared"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/vv2w-ky28"],"render_values":[{"text":"https://doi.org/10.7298/vv2w-ky28","href":"https://doi.org/10.7298/vv2w-ky28","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15049431"],"render_values":[{"text":"15049431","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11162","ProQuest Publication ID: 28491640"],"render_values":[{"text":"ProQuest Submission ID: 11162","href":null,"code":true},{"text":"ProQuest Publication ID: 28491640","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/109678","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/109678","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F109678","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Barbano, David Mark"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Novakovic, Andrew Milovan"]},{"key":"dc:creator","label":"Author","values":["Peterson, Emmalee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-09T17:38:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-09T17:38:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/15049431"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Food Science and Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Food Science and Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mid infrared"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15049431"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/vv2w-ky28"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11162","ProQuest Publication ID: 28491640"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/109678"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"76244c63-77b3-4d97-b62f-f6ae1b74deb1\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Rapid Analysis of Cheddar Cheese and Nonfat Dry Milk Using Mid Infrared Spectroscopy</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2021-05</PublicationDate> <DOI>https://doi.org/10.7298/vv2w-ky28</DOI> <Authors> <Author> <DisplayName>Peterson, Emmalee</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Keyword>Mid infrared</Keyword> <Abstract>The first objective of this work was to develop methods for the creation of liquid Cheddar cheese calibration standards and evaluate the calibration set using a combination MIR transmittance analysis and an in-line conductivity sensor within the MIR milk analyzer for measuring fat, protein, moisture, and salt content. Annatto colored cheese samples were collected from one cheese factory. Each cheese sample was analyzed using reference chemistry and then blended into a particle free dispersion to run through the FT-MIR. The remaining cheese was combined and used to create an 8-sample calibration set with decreasing amounts of fat, protein, total solids, and salt. Validation samples were also run using the new calibration model. Standard error of prediction (SEP) values for fat, moisture, and salt of the validation samples on the MIR produced SEP values for fat A+B, moisture, and salt of 0.177, 0.176, and 0.022, respectively. These low SEP values indicate that MIR could be used as an effective alternative to cheese producers for the rapid analysis of cheese using equipment most dairy processors already have in their facility. Our second objective was to develop and evaluate the performance of the rapid determination of fat, protein, lactose, and moisture of nonfat dry milk powders using mid-infrared transmittance analysis. Nonfat dry milk powders were reconstituted and analyzed using reference chemistry and the FT-MIR to create a calibration model. Validation was done at a separate time using the same nonfat dry milk powders. The SEP values for the validation samples were low. Moisture, fat A, protein, and lactose had SEP values of 0.292, 0.023, 0.110, and 0.334, respectively. This indicates that MIR could be used as an easy and effective way for NFDM producers to measure the components of their product.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Peterson, Emmalee"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["116 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["The first objective of this work was to develop methods for the creation of liquid Cheddar cheese calibration standards and evaluate the calibration set using a combination MIR transmittance analysis and an in-line conductivity sensor within the MIR milk analyzer for measuring fat, protein, moisture, and salt content. Annatto colored cheese samples were collected from one cheese factory. Each cheese sample was analyzed using reference chemistry and then blended into a particle free dispersion to run through the FT-MIR. The remaining cheese was combined and used to create an 8-sample calibration set with decreasing amounts of fat, protein, total solids, and salt. Validation samples were also run using the new calibration model. Standard error of prediction (SEP) values for fat, moisture, and salt of the validation samples on the MIR produced SEP values for fat A+B, moisture, and salt of 0.177, 0.176, and 0.022, respectively. These low SEP values indicate that MIR could be used as an effective alternative to cheese producers for the rapid analysis of cheese using equipment most dairy processors already have in their facility. Our second objective was to develop and evaluate the performance of the rapid determination of fat, protein, lactose, and moisture of nonfat dry milk powders using mid-infrared transmittance analysis. Nonfat dry milk powders were reconstituted and analyzed using reference chemistry and the FT-MIR to create a calibration model. Validation was done at a separate time using the same nonfat dry milk powders. The SEP values for the validation samples were low. Moisture, fat A, protein, and lactose had SEP values of 0.292, 0.023, 0.110, and 0.334, respectively. This indicates that MIR could be used as an easy and effective way for NFDM producers to measure the components of their product."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Rapid Analysis of Cheddar Cheese and Nonfat Dry Milk Using Mid Infrared Spectroscopy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"76244c63-77b3-4d97-b62f-f6ae1b74deb1\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Rapid Analysis of Cheddar Cheese and Nonfat Dry Milk Using Mid Infrared Spectroscopy</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2021-05</PublicationDate> <DOI>https://doi.org/10.7298/vv2w-ky28</DOI> <Authors> <Author> <DisplayName>Peterson, Emmalee</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Keyword>Mid infrared</Keyword> <Abstract>The first objective of this work was to develop methods for the creation of liquid Cheddar cheese calibration standards and evaluate the calibration set using a combination MIR transmittance analysis and an in-line conductivity sensor within the MIR milk analyzer for measuring fat, protein, moisture, and salt content. Annatto colored cheese samples were collected from one cheese factory. Each cheese sample was analyzed using reference chemistry and then blended into a particle free dispersion to run through the FT-MIR. The remaining cheese was combined and used to create an 8-sample calibration set with decreasing amounts of fat, protein, total solids, and salt. Validation samples were also run using the new calibration model. Standard error of prediction (SEP) values for fat, moisture, and salt of the validation samples on the MIR produced SEP values for fat A+B, moisture, and salt of 0.177, 0.176, and 0.022, respectively. These low SEP values indicate that MIR could be used as an effective alternative to cheese producers for the rapid analysis of cheese using equipment most dairy processors already have in their facility. Our second objective was to develop and evaluate the performance of the rapid determination of fat, protein, lactose, and moisture of nonfat dry milk powders using mid-infrared transmittance analysis. Nonfat dry milk powders were reconstituted and analyzed using reference chemistry and the FT-MIR to create a calibration model. Validation was done at a separate time using the same nonfat dry milk powders. The SEP values for the validation samples were low. Moisture, fat A, protein, and lactose had SEP values of 0.292, 0.023, 0.110, and 0.334, respectively. This indicates that MIR could be used as an easy and effective way for NFDM producers to measure the components of their product.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Peterson, Emmalee"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Barbano, David Mark"],"dc:contributor.committeemember":["Novakovic, Andrew Milovan"],"dc:creator":["Peterson, Emmalee"],"dc:date.accessioned":["2021-09-09T17:38:02Z"],"dc:date.available":["2021-09-09T17:38:02Z"],"dc:date.issued":["2021-05"],"dc:description":["116 pages"],"dc:description.abstract":["The first objective of this work was to develop methods for the creation of liquid Cheddar cheese calibration standards and evaluate the calibration set using a combination MIR transmittance analysis and an in-line conductivity sensor within the MIR milk analyzer for measuring fat, protein, moisture, and salt content. Annatto colored cheese samples were collected from one cheese factory. Each cheese sample was analyzed using reference chemistry and then blended into a particle free dispersion to run through the FT-MIR. The remaining cheese was combined and used to create an 8-sample calibration set with decreasing amounts of fat, protein, total solids, and salt. Validation samples were also run using the new calibration model. Standard error of prediction (SEP) values for fat, moisture, and salt of the validation samples on the MIR produced SEP values for fat A+B, moisture, and salt of 0.177, 0.176, and 0.022, respectively. These low SEP values indicate that MIR could be used as an effective alternative to cheese producers for the rapid analysis of cheese using equipment most dairy processors already have in their facility. Our second objective was to develop and evaluate the performance of the rapid determination of fat, protein, lactose, and moisture of nonfat dry milk powders using mid-infrared transmittance analysis. Nonfat dry milk powders were reconstituted and analyzed using reference chemistry and the FT-MIR to create a calibration model. Validation was done at a separate time using the same nonfat dry milk powders. The SEP values for the validation samples were low. Moisture, fat A, protein, and lactose had SEP values of 0.292, 0.023, 0.110, and 0.334, respectively. This indicates that MIR could be used as an easy and effective way for NFDM producers to measure the components of their product."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["15049431"],"dc:identifier.doi":["https://doi.org/10.7298/vv2w-ky28"],"dc:identifier.other":["ProQuest Submission ID: 11162","ProQuest Publication ID: 28491640"],"dc:identifier.uri":["https://hdl.handle.net/1813/109678"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/15049431"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Mid infrared"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Rapid Analysis of Cheddar Cheese and Nonfat Dry Milk Using Mid Infrared Spectroscopy"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Food Science and Technology"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Food Science and Technology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:08:55Z"}