{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/110919"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/110919","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"THE DEPTH LIMIT OF MULTIPHOTON MICROSCOPY AND APPLICATIONS TO IMAGING MINIATURE ADULT VERTEBRATE BRAINS","abstract":"Multiphoton microscopy has enabled unprecedented access to biological systems in their native environment. Two-photon microscopy was invented at Cornell University in 1990 and has since been adopted all over the world for deep in vivo imaging. While three-photon microscopy was demonstrated not much later (1996), the required technology and incentive for further development of this technique was not available until much later in 2013 once again at Cornell, the original home of multiphoton imaging. Three-photon microscopy has since enabled unprecedented access deep in highly scattering biological tissue.While the advantage of three-photon microscopy for deep imaging has been demonstrated, the depth limit of this technique had not been established. In this dissertation I provide a comprehensive theoretical and experimental investigation of the depth limit of multiphoton microscopy techniques. I demonstrate experimentally that high spatial resolution diffraction-limited imaging at a depth of 10 scattering mean-free paths, which is nearly twice the transport mean free path, is possible with multiphoton microscopy. Our results indicate that the depth limit of three-photon microscopy is significantly beyond what has been achieved in biological tissues so far, and further technological development is required to reach the full potential of three-photon microscopy. Additionally, I demonstrate unique possibilities that multiphoton microscopy enables in neuroscience research by applying three-photon microscopy and third harmonic generation microscopy to a miniature adult vertebrate, Danionella dracula. My work demonstrates that two- and three-photon microscopy can be used to access the entire depth of the adult wild type Danionella dracula brain without any modifications to the animal other than mechanical stabilization. These results show that multiphoton microscopy is ideal for readily penetrating the entire adult brain within the geometry of these miniature animals’ head structures, without the need for pigment removal. With multiphoton microscopy enabling optical access to the adult brain and a repertoire of methods that allow observation of the larval brain, Danionella provides a model system for readily studying the entire brain over the lifetime of a vertebrate for the first time.","abstract_html":"Multiphoton microscopy has enabled unprecedented access to biological systems in their native environment. Two-photon microscopy was invented at Cornell University in 1990 and has since been adopted all over the world for deep in vivo imaging. While three-photon microscopy was demonstrated not much later (1996), the required technology and incentive for further development of this technique was not available until much later in 2013 once again at Cornell, the original home of multiphoton imaging. Three-photon microscopy has since enabled unprecedented access deep in highly scattering biological tissue.While the advantage of three-photon microscopy for deep imaging has been demonstrated, the depth limit of this technique had not been established. In this dissertation I provide a comprehensive theoretical and experimental investigation of the depth limit of multiphoton microscopy techniques. I demonstrate experimentally that high spatial resolution diffraction-limited imaging at a depth of 10 scattering mean-free paths, which is nearly twice the transport mean free path, is possible with multiphoton microscopy. Our results indicate that the depth limit of three-photon microscopy is significantly beyond what has been achieved in biological tissues so far, and further technological development is required to reach the full potential of three-photon microscopy. Additionally, I demonstrate unique possibilities that multiphoton microscopy enables in neuroscience research by applying three-photon microscopy and third harmonic generation microscopy to a miniature adult vertebrate, Danionella dracula. My work demonstrates that two- and three-photon microscopy can be used to access the entire depth of the adult wild type Danionella dracula brain without any modifications to the animal other than mechanical stabilization. These results show that multiphoton microscopy is ideal for readily penetrating the entire adult brain within the geometry of these miniature animals’ head structures, without the need for pigment removal. With multiphoton microscopy enabling optical access to the adult brain and a repertoire of methods that allow observation of the larval brain, Danionella provides a model system for readily studying the entire brain over the lifetime of a vertebrate for the first time.","abstract_has_math":false,"creators":["Akbari, Najva"],"institution":"Cornell University","degree_name":"Ph. D., Applied Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Xu, Chris"],"committee_members":["Schaffer, Chris","Fetcho, Joseph R."],"year":2021,"date_issued":"2021-12","date_published":"2021-12","updated_at":"2026-11-19T03:09:31Z","subjects":["Danionella","Multiphoton Microscopy","Neuroscience","Zebrafish"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/459n-qk89"],"render_values":[{"text":"https://doi.org/10.7298/459n-qk89","href":"https://doi.org/10.7298/459n-qk89","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15312776"],"render_values":[{"text":"15312776","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12871","ProQuest Publication ID: 28863518"],"render_values":[{"text":"ProQuest Submission ID: 12871","href":null,"code":true},{"text":"ProQuest Publication ID: 28863518","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/110919","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/110919","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F110919","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Xu, Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Schaffer, Chris","Fetcho, Joseph R."]},{"key":"dc:creator","label":"Author","values":["Akbari, Najva"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-01-24T18:08:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-05T07:00:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-12"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/15312776"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Danionella","Multiphoton Microscopy","Neuroscience","Zebrafish"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15312776"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/459n-qk89"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12871","ProQuest Publication ID: 28863518"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/110919"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"eadca82f-75af-411a-980b-4db2a6f584db\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>THE DEPTH LIMIT OF MULTIPHOTON MICROSCOPY AND APPLICATIONS TO IMAGING MINIATURE ADULT VERTEBRATE BRAINS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2021-12</PublicationDate> <DOI>https://doi.org/10.7298/459n-qk89</DOI> <Authors> <Author> <DisplayName>Akbari, Najva</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Danionella</Keyword> <Keyword>Multiphoton Microscopy</Keyword> <Keyword>Neuroscience</Keyword> <Keyword>Zebrafish</Keyword> <Abstract>Multiphoton microscopy has enabled unprecedented access to biological systems in their native environment. Two-photon microscopy was invented at Cornell University in 1990 and has since been adopted all over the world for deep in vivo imaging. While three-photon microscopy was demonstrated not much later (1996), the required technology and incentive for further development of this technique was not available until much later in 2013 once again at Cornell, the original home of multiphoton imaging. Three-photon microscopy has since enabled unprecedented access deep in highly scattering biological tissue.While the advantage of three-photon microscopy for deep imaging has been demonstrated, the depth limit of this technique had not been established. In this dissertation I provide a comprehensive theoretical and experimental investigation of the depth limit of multiphoton microscopy techniques. I demonstrate experimentally that high spatial resolution diffraction-limited imaging at a depth of 10 scattering mean-free paths, which is nearly twice the transport mean free path, is possible with multiphoton microscopy. Our results indicate that the depth limit of three-photon microscopy is significantly beyond what has been achieved in biological tissues so far, and further technological development is required to reach the full potential of three-photon microscopy. Additionally, I demonstrate unique possibilities that multiphoton microscopy enables in neuroscience research by applying three-photon microscopy and third harmonic generation microscopy to a miniature adult vertebrate, Danionella dracula. My work demonstrates that two- and three-photon microscopy can be used to access the entire depth of the adult wild type Danionella dracula brain without any modifications to the animal other than mechanical stabilization. These results show that multiphoton microscopy is ideal for readily penetrating the entire adult brain within the geometry of these miniature animals’ head structures, without the need for pigment removal. With multiphoton microscopy enabling optical access to the adult brain and a repertoire of methods that allow observation of the larval brain, Danionella provides a model system for readily studying the entire brain over the lifetime of a vertebrate for the first time.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Akbari, Najva"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["125 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Multiphoton microscopy has enabled unprecedented access to biological systems in their native environment. Two-photon microscopy was invented at Cornell University in 1990 and has since been adopted all over the world for deep in vivo imaging. While three-photon microscopy was demonstrated not much later (1996), the required technology and incentive for further development of this technique was not available until much later in 2013 once again at Cornell, the original home of multiphoton imaging. Three-photon microscopy has since enabled unprecedented access deep in highly scattering biological tissue.While the advantage of three-photon microscopy for deep imaging has been demonstrated, the depth limit of this technique had not been established. In this dissertation I provide a comprehensive theoretical and experimental investigation of the depth limit of multiphoton microscopy techniques. I demonstrate experimentally that high spatial resolution diffraction-limited imaging at a depth of 10 scattering mean-free paths, which is nearly twice the transport mean free path, is possible with multiphoton microscopy. Our results indicate that the depth limit of three-photon microscopy is significantly beyond what has been achieved in biological tissues so far, and further technological development is required to reach the full potential of three-photon microscopy. Additionally, I demonstrate unique possibilities that multiphoton microscopy enables in neuroscience research by applying three-photon microscopy and third harmonic generation microscopy to a miniature adult vertebrate, Danionella dracula. My work demonstrates that two- and three-photon microscopy can be used to access the entire depth of the adult wild type Danionella dracula brain without any modifications to the animal other than mechanical stabilization. These results show that multiphoton microscopy is ideal for readily penetrating the entire adult brain within the geometry of these miniature animals’ head structures, without the need for pigment removal. With multiphoton microscopy enabling optical access to the adult brain and a repertoire of methods that allow observation of the larval brain, Danionella provides a model system for readily studying the entire brain over the lifetime of a vertebrate for the first time."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["THE DEPTH LIMIT OF MULTIPHOTON MICROSCOPY AND APPLICATIONS TO IMAGING MINIATURE ADULT VERTEBRATE BRAINS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"eadca82f-75af-411a-980b-4db2a6f584db\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>THE DEPTH LIMIT OF MULTIPHOTON MICROSCOPY AND APPLICATIONS TO IMAGING MINIATURE ADULT VERTEBRATE BRAINS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2021-12</PublicationDate> <DOI>https://doi.org/10.7298/459n-qk89</DOI> <Authors> <Author> <DisplayName>Akbari, Najva</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Danionella</Keyword> <Keyword>Multiphoton Microscopy</Keyword> <Keyword>Neuroscience</Keyword> <Keyword>Zebrafish</Keyword> <Abstract>Multiphoton microscopy has enabled unprecedented access to biological systems in their native environment. Two-photon microscopy was invented at Cornell University in 1990 and has since been adopted all over the world for deep in vivo imaging. While three-photon microscopy was demonstrated not much later (1996), the required technology and incentive for further development of this technique was not available until much later in 2013 once again at Cornell, the original home of multiphoton imaging. Three-photon microscopy has since enabled unprecedented access deep in highly scattering biological tissue.While the advantage of three-photon microscopy for deep imaging has been demonstrated, the depth limit of this technique had not been established. In this dissertation I provide a comprehensive theoretical and experimental investigation of the depth limit of multiphoton microscopy techniques. I demonstrate experimentally that high spatial resolution diffraction-limited imaging at a depth of 10 scattering mean-free paths, which is nearly twice the transport mean free path, is possible with multiphoton microscopy. Our results indicate that the depth limit of three-photon microscopy is significantly beyond what has been achieved in biological tissues so far, and further technological development is required to reach the full potential of three-photon microscopy. Additionally, I demonstrate unique possibilities that multiphoton microscopy enables in neuroscience research by applying three-photon microscopy and third harmonic generation microscopy to a miniature adult vertebrate, Danionella dracula. My work demonstrates that two- and three-photon microscopy can be used to access the entire depth of the adult wild type Danionella dracula brain without any modifications to the animal other than mechanical stabilization. These results show that multiphoton microscopy is ideal for readily penetrating the entire adult brain within the geometry of these miniature animals’ head structures, without the need for pigment removal. With multiphoton microscopy enabling optical access to the adult brain and a repertoire of methods that allow observation of the larval brain, Danionella provides a model system for readily studying the entire brain over the lifetime of a vertebrate for the first time.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Akbari, Najva"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Xu, Chris"],"dc:contributor.committeemember":["Schaffer, Chris","Fetcho, Joseph R."],"dc:creator":["Akbari, Najva"],"dc:date.accessioned":["2022-01-24T18:08:20Z"],"dc:date.available":["2023-01-05T07:00:34Z"],"dc:date.issued":["2021-12"],"dc:description":["125 pages"],"dc:description.abstract":["Multiphoton microscopy has enabled unprecedented access to biological systems in their native environment. Two-photon microscopy was invented at Cornell University in 1990 and has since been adopted all over the world for deep in vivo imaging. While three-photon microscopy was demonstrated not much later (1996), the required technology and incentive for further development of this technique was not available until much later in 2013 once again at Cornell, the original home of multiphoton imaging. Three-photon microscopy has since enabled unprecedented access deep in highly scattering biological tissue.While the advantage of three-photon microscopy for deep imaging has been demonstrated, the depth limit of this technique had not been established. In this dissertation I provide a comprehensive theoretical and experimental investigation of the depth limit of multiphoton microscopy techniques. I demonstrate experimentally that high spatial resolution diffraction-limited imaging at a depth of 10 scattering mean-free paths, which is nearly twice the transport mean free path, is possible with multiphoton microscopy. Our results indicate that the depth limit of three-photon microscopy is significantly beyond what has been achieved in biological tissues so far, and further technological development is required to reach the full potential of three-photon microscopy. Additionally, I demonstrate unique possibilities that multiphoton microscopy enables in neuroscience research by applying three-photon microscopy and third harmonic generation microscopy to a miniature adult vertebrate, Danionella dracula. My work demonstrates that two- and three-photon microscopy can be used to access the entire depth of the adult wild type Danionella dracula brain without any modifications to the animal other than mechanical stabilization. These results show that multiphoton microscopy is ideal for readily penetrating the entire adult brain within the geometry of these miniature animals’ head structures, without the need for pigment removal. With multiphoton microscopy enabling optical access to the adult brain and a repertoire of methods that allow observation of the larval brain, Danionella provides a model system for readily studying the entire brain over the lifetime of a vertebrate for the first time."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["15312776"],"dc:identifier.doi":["https://doi.org/10.7298/459n-qk89"],"dc:identifier.other":["ProQuest Submission ID: 12871","ProQuest Publication ID: 28863518"],"dc:identifier.uri":["https://hdl.handle.net/1813/110919"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/15312776"],"dc:subject":["Danionella","Multiphoton Microscopy","Neuroscience","Zebrafish"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["THE DEPTH LIMIT OF MULTIPHOTON MICROSCOPY AND APPLICATIONS TO IMAGING MINIATURE ADULT VERTEBRATE BRAINS"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Applied Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:09:31Z"}