{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/111605"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/111605","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Designing Porous Structures for Orthopedic Applications Using Additive Manufacturing","abstract":"The need to develop better materials for fabricating orthopedic implants is the key to manufacturing longer lasting implants with a reduced chance of early failure and the need for revision surgeries. This work aims to provide a logical and methodical approach in designing porous structures using tools such as Topology Optimization (TO), Computer Aided Design (CAD) and Finite Element Analysis (FEA) alongside Additive Manufacturing (AM) to fabricate orthopedic implants.Porous structures were designed using topology optimization to tailor mechanical properties that match that of the human bone. The mechanical properties of suitable structures were determined computationally using finite element analysis. Further, the structures depicting desirable properties were manufactured using Electron Beam Melting (EBM) to experimentally verify their mechanical properties. The results show that we were able to successfully design a porous structure that had a Young’s modulus as low as 1.7 GPa which falls well within the range of that of human bone making it a viable material for developing orthopedic implants.","abstract_html":"The need to develop better materials for fabricating orthopedic implants is the key to manufacturing longer lasting implants with a reduced chance of early failure and the need for revision surgeries. This work aims to provide a logical and methodical approach in designing porous structures using tools such as Topology Optimization (TO), Computer Aided Design (CAD) and Finite Element Analysis (FEA) alongside Additive Manufacturing (AM) to fabricate orthopedic implants.Porous structures were designed using topology optimization to tailor mechanical properties that match that of the human bone. The mechanical properties of suitable structures were determined computationally using finite element analysis. Further, the structures depicting desirable properties were manufactured using Electron Beam Melting (EBM) to experimentally verify their mechanical properties. The results show that we were able to successfully design a porous structure that had a Young’s modulus as low as 1.7 GPa which falls well within the range of that of human bone making it a viable material for developing orthopedic implants.","abstract_has_math":false,"creators":["Bhattacharya, Shonak"],"institution":"Cornell University","degree_name":"M.S., Mechanical Engineering","degree_level":"Master of Science","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Moridi, Atieh"],"committee_members":["Bouklas, Nikolaos"],"year":2022,"date_issued":"2022-05","date_published":"2022-05","updated_at":"2026-11-19T03:09:31Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/j5jc-d515"],"render_values":[{"text":"https://doi.org/10.7298/j5jc-d515","href":"https://doi.org/10.7298/j5jc-d515","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15530036"],"render_values":[{"text":"15530036","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11417","ProQuest Publication ID: 28961909"],"render_values":[{"text":"ProQuest Submission ID: 11417","href":null,"code":true},{"text":"ProQuest Publication ID: 28961909","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/111605","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/111605","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F111605","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Moridi, Atieh"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bouklas, Nikolaos"]},{"key":"dc:creator","label":"Author","values":["Bhattacharya, Shonak"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-09-15T15:49:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-09-15T15:49:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/15530036"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15530036"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/j5jc-d515"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11417","ProQuest Publication ID: 28961909"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/111605"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"d9d8d395-a155-4711-b992-3e8f536e34b0\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Designing Porous Structures for Orthopedic Applications Using Additive Manufacturing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-05</PublicationDate> <DOI>https://doi.org/10.7298/j5jc-d515</DOI> <Authors> <Author> <DisplayName>Bhattacharya, Shonak</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>The need to develop better materials for fabricating orthopedic implants is the key to manufacturing longer lasting implants with a reduced chance of early failure and the need for revision surgeries. This work aims to provide a logical and methodical approach in designing porous structures using tools such as Topology Optimization (TO), Computer Aided Design (CAD) and Finite Element Analysis (FEA) alongside Additive Manufacturing (AM) to fabricate orthopedic implants.Porous structures were designed using topology optimization to tailor mechanical properties that match that of the human bone. The mechanical properties of suitable structures were determined computationally using finite element analysis. Further, the structures depicting desirable properties were manufactured using Electron Beam Melting (EBM) to experimentally verify their mechanical properties. The results show that we were able to successfully design a porous structure that had a Young’s modulus as low as 1.7 GPa which falls well within the range of that of human bone making it a viable material for developing orthopedic implants.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Bhattacharya, Shonak"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["67 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["The need to develop better materials for fabricating orthopedic implants is the key to manufacturing longer lasting implants with a reduced chance of early failure and the need for revision surgeries. This work aims to provide a logical and methodical approach in designing porous structures using tools such as Topology Optimization (TO), Computer Aided Design (CAD) and Finite Element Analysis (FEA) alongside Additive Manufacturing (AM) to fabricate orthopedic implants.Porous structures were designed using topology optimization to tailor mechanical properties that match that of the human bone. The mechanical properties of suitable structures were determined computationally using finite element analysis. Further, the structures depicting desirable properties were manufactured using Electron Beam Melting (EBM) to experimentally verify their mechanical properties. The results show that we were able to successfully design a porous structure that had a Young’s modulus as low as 1.7 GPa which falls well within the range of that of human bone making it a viable material for developing orthopedic implants."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Designing Porous Structures for Orthopedic Applications Using Additive Manufacturing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"d9d8d395-a155-4711-b992-3e8f536e34b0\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Designing Porous Structures for Orthopedic Applications Using Additive Manufacturing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-05</PublicationDate> <DOI>https://doi.org/10.7298/j5jc-d515</DOI> <Authors> <Author> <DisplayName>Bhattacharya, Shonak</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>The need to develop better materials for fabricating orthopedic implants is the key to manufacturing longer lasting implants with a reduced chance of early failure and the need for revision surgeries. This work aims to provide a logical and methodical approach in designing porous structures using tools such as Topology Optimization (TO), Computer Aided Design (CAD) and Finite Element Analysis (FEA) alongside Additive Manufacturing (AM) to fabricate orthopedic implants.Porous structures were designed using topology optimization to tailor mechanical properties that match that of the human bone. The mechanical properties of suitable structures were determined computationally using finite element analysis. Further, the structures depicting desirable properties were manufactured using Electron Beam Melting (EBM) to experimentally verify their mechanical properties. The results show that we were able to successfully design a porous structure that had a Young’s modulus as low as 1.7 GPa which falls well within the range of that of human bone making it a viable material for developing orthopedic implants.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Bhattacharya, Shonak"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Moridi, Atieh"],"dc:contributor.committeemember":["Bouklas, Nikolaos"],"dc:creator":["Bhattacharya, Shonak"],"dc:date.accessioned":["2022-09-15T15:49:05Z"],"dc:date.available":["2022-09-15T15:49:05Z"],"dc:date.issued":["2022-05"],"dc:description":["67 pages"],"dc:description.abstract":["The need to develop better materials for fabricating orthopedic implants is the key to manufacturing longer lasting implants with a reduced chance of early failure and the need for revision surgeries. This work aims to provide a logical and methodical approach in designing porous structures using tools such as Topology Optimization (TO), Computer Aided Design (CAD) and Finite Element Analysis (FEA) alongside Additive Manufacturing (AM) to fabricate orthopedic implants.Porous structures were designed using topology optimization to tailor mechanical properties that match that of the human bone. The mechanical properties of suitable structures were determined computationally using finite element analysis. Further, the structures depicting desirable properties were manufactured using Electron Beam Melting (EBM) to experimentally verify their mechanical properties. The results show that we were able to successfully design a porous structure that had a Young’s modulus as low as 1.7 GPa which falls well within the range of that of human bone making it a viable material for developing orthopedic implants."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["15530036"],"dc:identifier.doi":["https://doi.org/10.7298/j5jc-d515"],"dc:identifier.other":["ProQuest Submission ID: 11417","ProQuest Publication ID: 28961909"],"dc:identifier.uri":["https://hdl.handle.net/1813/111605"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/15530036"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Designing Porous Structures for Orthopedic Applications Using Additive Manufacturing"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:09:31Z"}