{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/111819"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/111819","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Computational and Hardware Adaptive Optics for Biomedical Imaging with Optical Coherence Tomography","abstract":"Optical coherence tomography (OCT) is an emerging technology that enables volumetric imaging of biological samples. OCT has several advantages over other imaging modalities, including parallel depth acquisition, access to complex optical field and label free. Optical coherence microscopy (OCM) is a higher-transverse-resolution version of OCT.The basic science applications of OCT and OCM are expanding, and one important application area involves imaging in the rat and mouse brain. However, there are several challenges for current biomedical application of OCT/OCM. The first challenge is the compromise between lateral resolution and depth-of-field (DOF), which has limited the volumetric imaging throughput of OCT. Another challenge is related to the multiple scattering (MS) in the biological sample, which severely limits the imaging depth of an OCT system. In this dissertation, I will first present volumetric OCM of mouse brain ex vivo with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. I will also present a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare aberration-diverse optical coherence tomography (AD-OCT), a previously published technique for MS suppression, to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Besides that, a theoretical study will be presented to study the transverse point-spread function (PSF) in presence of MS and investigate the effect of different factors on the MS suppression performance provided by AD-OCT.","abstract_html":"Optical coherence tomography (OCT) is an emerging technology that enables volumetric imaging of biological samples. OCT has several advantages over other imaging modalities, including parallel depth acquisition, access to complex optical field and label free. Optical coherence microscopy (OCM) is a higher-transverse-resolution version of OCT.The basic science applications of OCT and OCM are expanding, and one important application area involves imaging in the rat and mouse brain. However, there are several challenges for current biomedical application of OCT/OCM. The first challenge is the compromise between lateral resolution and depth-of-field (DOF), which has limited the volumetric imaging throughput of OCT. Another challenge is related to the multiple scattering (MS) in the biological sample, which severely limits the imaging depth of an OCT system. In this dissertation, I will first present volumetric OCM of mouse brain ex vivo with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. I will also present a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare aberration-diverse optical coherence tomography (AD-OCT), a previously published technique for MS suppression, to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Besides that, a theoretical study will be presented to study the transverse point-spread function (PSF) in presence of MS and investigate the effect of different factors on the MS suppression performance provided by AD-OCT.","abstract_has_math":false,"creators":["Wu, Meiqi"],"institution":"Cornell University","degree_name":"Ph. D., Biomedical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Adie, Steven Graham"],"committee_members":["Xu, Chris","Warden, Melissa"],"year":2022,"date_issued":"2022-05","date_published":"2022-05","updated_at":"2026-11-19T03:10:05Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/0pnm-8r54"],"render_values":[{"text":"https://doi.org/10.7298/0pnm-8r54","href":"https://doi.org/10.7298/0pnm-8r54","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15530007"],"render_values":[{"text":"15530007","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12911","ProQuest Publication ID: 28868959"],"render_values":[{"text":"ProQuest Submission ID: 12911","href":null,"code":true},{"text":"ProQuest Publication ID: 28868959","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/111819","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/111819","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F111819","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Adie, Steven Graham"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Xu, Chris","Warden, Melissa"]},{"key":"dc:creator","label":"Author","values":["Wu, Meiqi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-09-15T15:51:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/15530007"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15530007"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/0pnm-8r54"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12911","ProQuest Publication ID: 28868959"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/111819"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"f5b3ad09-07e4-4249-8dac-a547d2d6a140\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Computational and Hardware Adaptive Optics for Biomedical Imaging with Optical Coherence Tomography</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-05</PublicationDate> <DOI>https://doi.org/10.7298/0pnm-8r54</DOI> <Authors> <Author> <DisplayName>Wu, Meiqi</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Optical coherence tomography (OCT) is an emerging technology that enables volumetric imaging of biological samples. OCT has several advantages over other imaging modalities, including parallel depth acquisition, access to complex optical field and label free. Optical coherence microscopy (OCM) is a higher-transverse-resolution version of OCT.The basic science applications of OCT and OCM are expanding, and one important application area involves imaging in the rat and mouse brain. However, there are several challenges for current biomedical application of OCT/OCM. The first challenge is the compromise between lateral resolution and depth-of-field (DOF), which has limited the volumetric imaging throughput of OCT. Another challenge is related to the multiple scattering (MS) in the biological sample, which severely limits the imaging depth of an OCT system. In this dissertation, I will first present volumetric OCM of mouse brain ex vivo with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. I will also present a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare aberration-diverse optical coherence tomography (AD-OCT), a previously published technique for MS suppression, to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Besides that, a theoretical study will be presented to study the transverse point-spread function (PSF) in presence of MS and investigate the effect of different factors on the MS suppression performance provided by AD-OCT.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Wu, Meiqi"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["156 pages","Supplemental file(s) description: Videos."]},{"key":"dc:description.abstract","label":"Abstract","values":["Optical coherence tomography (OCT) is an emerging technology that enables volumetric imaging of biological samples. OCT has several advantages over other imaging modalities, including parallel depth acquisition, access to complex optical field and label free. Optical coherence microscopy (OCM) is a higher-transverse-resolution version of OCT.The basic science applications of OCT and OCM are expanding, and one important application area involves imaging in the rat and mouse brain. However, there are several challenges for current biomedical application of OCT/OCM. The first challenge is the compromise between lateral resolution and depth-of-field (DOF), which has limited the volumetric imaging throughput of OCT. Another challenge is related to the multiple scattering (MS) in the biological sample, which severely limits the imaging depth of an OCT system. In this dissertation, I will first present volumetric OCM of mouse brain ex vivo with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. I will also present a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare aberration-diverse optical coherence tomography (AD-OCT), a previously published technique for MS suppression, to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Besides that, a theoretical study will be presented to study the transverse point-spread function (PSF) in presence of MS and investigate the effect of different factors on the MS suppression performance provided by AD-OCT."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","application/zip"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Computational and Hardware Adaptive Optics for Biomedical Imaging with Optical Coherence Tomography"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"f5b3ad09-07e4-4249-8dac-a547d2d6a140\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Computational and Hardware Adaptive Optics for Biomedical Imaging with Optical Coherence Tomography</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-05</PublicationDate> <DOI>https://doi.org/10.7298/0pnm-8r54</DOI> <Authors> <Author> <DisplayName>Wu, Meiqi</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Optical coherence tomography (OCT) is an emerging technology that enables volumetric imaging of biological samples. OCT has several advantages over other imaging modalities, including parallel depth acquisition, access to complex optical field and label free. Optical coherence microscopy (OCM) is a higher-transverse-resolution version of OCT.The basic science applications of OCT and OCM are expanding, and one important application area involves imaging in the rat and mouse brain. However, there are several challenges for current biomedical application of OCT/OCM. The first challenge is the compromise between lateral resolution and depth-of-field (DOF), which has limited the volumetric imaging throughput of OCT. Another challenge is related to the multiple scattering (MS) in the biological sample, which severely limits the imaging depth of an OCT system. In this dissertation, I will first present volumetric OCM of mouse brain ex vivo with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. I will also present a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare aberration-diverse optical coherence tomography (AD-OCT), a previously published technique for MS suppression, to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Besides that, a theoretical study will be presented to study the transverse point-spread function (PSF) in presence of MS and investigate the effect of different factors on the MS suppression performance provided by AD-OCT.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Wu, Meiqi"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Adie, Steven Graham"],"dc:contributor.committeemember":["Xu, Chris","Warden, Melissa"],"dc:creator":["Wu, Meiqi"],"dc:date.accessioned":["2022-09-15T15:51:42Z"],"dc:date.issued":["2022-05"],"dc:description":["156 pages","Supplemental file(s) description: Videos."],"dc:description.abstract":["Optical coherence tomography (OCT) is an emerging technology that enables volumetric imaging of biological samples. OCT has several advantages over other imaging modalities, including parallel depth acquisition, access to complex optical field and label free. Optical coherence microscopy (OCM) is a higher-transverse-resolution version of OCT.The basic science applications of OCT and OCM are expanding, and one important application area involves imaging in the rat and mouse brain. However, there are several challenges for current biomedical application of OCT/OCM. The first challenge is the compromise between lateral resolution and depth-of-field (DOF), which has limited the volumetric imaging throughput of OCT. Another challenge is related to the multiple scattering (MS) in the biological sample, which severely limits the imaging depth of an OCT system. In this dissertation, I will first present volumetric OCM of mouse brain ex vivo with a large depth coverage by leveraging computational adaptive optics (CAO) to significantly reduce the number of OCM volumes that need to be acquired with a Gaussian beam focused at different depths. I will also present a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare aberration-diverse optical coherence tomography (AD-OCT), a previously published technique for MS suppression, to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Besides that, a theoretical study will be presented to study the transverse point-spread function (PSF) in presence of MS and investigate the effect of different factors on the MS suppression performance provided by AD-OCT."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf","application/zip"],"dc:identifier.bibid":["15530007"],"dc:identifier.doi":["https://doi.org/10.7298/0pnm-8r54"],"dc:identifier.other":["ProQuest Submission ID: 12911","ProQuest Publication ID: 28868959"],"dc:identifier.uri":["https://hdl.handle.net/1813/111819"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/15530007"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Computational and Hardware Adaptive Optics for Biomedical Imaging with Optical Coherence Tomography"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Biomedical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:10:05Z"}