{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/112123"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/112123","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Design and Construction of a High-Frequency Permeameter","abstract":"Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is crucial to optimally design the novel components for the devices needed for the evolving communications field. Therefore, a high-frequency magnetic permeability measurement system is presented. By making use of a lock-in amplifier, the system introduces a modulating waveform to distinguish minute signal changes due to perturbations induced by the presence of a magnetic material. As a result, by exploiting the lock-in amplifier’s ability to discern its contributions to the final signal produced by the system, magnetic permeability calculations due to observed changes in power are vastly improved by disregarding additional noise the system will inevitably encounter.","abstract_html":"Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is crucial to optimally design the novel components for the devices needed for the evolving communications field. Therefore, a high-frequency magnetic permeability measurement system is presented. By making use of a lock-in amplifier, the system introduces a modulating waveform to distinguish minute signal changes due to perturbations induced by the presence of a magnetic material. As a result, by exploiting the lock-in amplifier’s ability to discern its contributions to the final signal produced by the system, magnetic permeability calculations due to observed changes in power are vastly improved by disregarding additional noise the system will inevitably encounter.","abstract_has_math":false,"creators":["Correa, Maritza Elizabeth"],"institution":"Cornell University","degree_name":"M.S., Materials Science and Engineering","degree_level":"Master of Science","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["El-Ghazaly, Amal"],"committee_members":["Kan, Edwin C."],"year":2022,"date_issued":"2022-08","date_published":"2022-08","updated_at":"2026-11-19T03:10:05Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/zn7x-n263"],"render_values":[{"text":"https://doi.org/10.7298/zn7x-n263","href":"https://doi.org/10.7298/zn7x-n263","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15578938"],"render_values":[{"text":"15578938","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11548","ProQuest Publication ID: 29323804"],"render_values":[{"text":"ProQuest Submission ID: 11548","href":null,"code":true},{"text":"ProQuest Publication ID: 29323804","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/112123","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/112123","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F112123","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["El-Ghazaly, Amal"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kan, Edwin C."]},{"key":"dc:creator","label":"Author","values":["Correa, Maritza Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-10-31T16:23:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-10-31T16:23:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-08"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/15578938"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Materials Science and Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15578938"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/zn7x-n263"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11548","ProQuest Publication ID: 29323804"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/112123"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c46e1bab-643d-4fd0-bc49-7f6b90937bdf\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design and Construction of a High-Frequency Permeameter</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-08</PublicationDate> <DOI>https://doi.org/10.7298/zn7x-n263</DOI> <Authors> <Author> <DisplayName>Correa, Maritza Elizabeth</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is crucial to optimally design the novel components for the devices needed for the evolving communications field. Therefore, a high-frequency magnetic permeability measurement system is presented. By making use of a lock-in amplifier, the system introduces a modulating waveform to distinguish minute signal changes due to perturbations induced by the presence of a magnetic material. As a result, by exploiting the lock-in amplifier’s ability to discern its contributions to the final signal produced by the system, magnetic permeability calculations due to observed changes in power are vastly improved by disregarding additional noise the system will inevitably encounter.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Correa, Maritza Elizabeth"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["25 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is crucial to optimally design the novel components for the devices needed for the evolving communications field. Therefore, a high-frequency magnetic permeability measurement system is presented. By making use of a lock-in amplifier, the system introduces a modulating waveform to distinguish minute signal changes due to perturbations induced by the presence of a magnetic material. As a result, by exploiting the lock-in amplifier’s ability to discern its contributions to the final signal produced by the system, magnetic permeability calculations due to observed changes in power are vastly improved by disregarding additional noise the system will inevitably encounter."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Design and Construction of a High-Frequency Permeameter"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c46e1bab-643d-4fd0-bc49-7f6b90937bdf\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design and Construction of a High-Frequency Permeameter</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-08</PublicationDate> <DOI>https://doi.org/10.7298/zn7x-n263</DOI> <Authors> <Author> <DisplayName>Correa, Maritza Elizabeth</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is crucial to optimally design the novel components for the devices needed for the evolving communications field. Therefore, a high-frequency magnetic permeability measurement system is presented. By making use of a lock-in amplifier, the system introduces a modulating waveform to distinguish minute signal changes due to perturbations induced by the presence of a magnetic material. As a result, by exploiting the lock-in amplifier’s ability to discern its contributions to the final signal produced by the system, magnetic permeability calculations due to observed changes in power are vastly improved by disregarding additional noise the system will inevitably encounter.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Correa, Maritza Elizabeth"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["El-Ghazaly, Amal"],"dc:contributor.committeemember":["Kan, Edwin C."],"dc:creator":["Correa, Maritza Elizabeth"],"dc:date.accessioned":["2022-10-31T16:23:51Z"],"dc:date.available":["2022-10-31T16:23:51Z"],"dc:date.issued":["2022-08"],"dc:description":["25 pages"],"dc:description.abstract":["Communications are currently progressing toward higher frequency ranges. Devices like transmitters and receivers, which make use of components like inductors, are the foundation of communications. Inductance plays a critical role in the performance of these devices and material characterization is crucial to optimally design the novel components for the devices needed for the evolving communications field. Therefore, a high-frequency magnetic permeability measurement system is presented. By making use of a lock-in amplifier, the system introduces a modulating waveform to distinguish minute signal changes due to perturbations induced by the presence of a magnetic material. As a result, by exploiting the lock-in amplifier’s ability to discern its contributions to the final signal produced by the system, magnetic permeability calculations due to observed changes in power are vastly improved by disregarding additional noise the system will inevitably encounter."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["15578938"],"dc:identifier.doi":["https://doi.org/10.7298/zn7x-n263"],"dc:identifier.other":["ProQuest Submission ID: 11548","ProQuest Publication ID: 29323804"],"dc:identifier.uri":["https://hdl.handle.net/1813/112123"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/15578938"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Design and Construction of a High-Frequency Permeameter"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Materials Science and Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:10:05Z"}