{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/113021"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/113021","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"IMPACTS OF SCALABLE ENERGY STORAGE SYSTEM TECHNOLOGIES AND RENEWABLE ENERGY INTEGRATION ON THE RENEWABLE ENERGY TRANSITION IN THE NEW YORK STATE","abstract":"In light of current energy policies responding to rapid climate change, much attention has been directed to developing feasible approaches for transitioning energy production from fossil-based resources to renewable energy (RE). Although existing studies analyze RE's regional dispatch and capacity planning, they do not fully explore the impacts of the energy storage system (ESS) technology's technical and economic characteristics on RE integration and energy transition. To fill this gap, we propose an integrated optimal power flow and multiple criteria decision-making model (OPF-MCDM) to minimize system cost under operational constraints and evaluate the operational performance of ESS technologies with multiple criteria. Through analysis of hundreds of scenarios, the proposed method can identify the most critical features of ESS technologies to enhance RE integration and achieve New York State's climate goals from 2025 to 2040. For example, we discover that hydrogen energy storage (HES), with the highest energy loss values, requires greater installed capacities (7,419 MW of RE and 398 MW of ESS) than the lithium-ion battery (LIB) in 2040 and generates 4.2% more carbon dioxide emissions than LIB on average. Based on the cross-sensitivity analysis in the multidimensional evaluation, underground compressed air energy storage (CAES) performs the best, and HES performs the worst when reaching zero carbon dioxide emissions target in 2040. The proposed OPF-MCDM’s results can also be conveniently generalized to select ESS technology based on the criteria preferences from RE integration and energy transition studies and serve as a reference for ESS configurations in future energy and power system planning.","abstract_html":"In light of current energy policies responding to rapid climate change, much attention has been directed to developing feasible approaches for transitioning energy production from fossil-based resources to renewable energy (RE). Although existing studies analyze RE&#x27;s regional dispatch and capacity planning, they do not fully explore the impacts of the energy storage system (ESS) technology&#x27;s technical and economic characteristics on RE integration and energy transition. To fill this gap, we propose an integrated optimal power flow and multiple criteria decision-making model (OPF-MCDM) to minimize system cost under operational constraints and evaluate the operational performance of ESS technologies with multiple criteria. Through analysis of hundreds of scenarios, the proposed method can identify the most critical features of ESS technologies to enhance RE integration and achieve New York State&#x27;s climate goals from 2025 to 2040. For example, we discover that hydrogen energy storage (HES), with the highest energy loss values, requires greater installed capacities (7,419 MW of RE and 398 MW of ESS) than the lithium-ion battery (LIB) in 2040 and generates 4.2% more carbon dioxide emissions than LIB on average. Based on the cross-sensitivity analysis in the multidimensional evaluation, underground compressed air energy storage (CAES) performs the best, and HES performs the worst when reaching zero carbon dioxide emissions target in 2040. The proposed OPF-MCDM’s results can also be conveniently generalized to select ESS technology based on the criteria preferences from RE integration and energy transition studies and serve as a reference for ESS configurations in future energy and power system planning.","abstract_has_math":false,"creators":["Huang, Wei-Chieh"],"institution":"Cornell University","degree_name":"M.S., Systems Engineering","degree_level":"Master of Science","degree_discipline":"Systems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["You, Fengqi"],"committee_members":["Anderson, Catherine"],"year":2022,"date_issued":"2022-12","date_published":"2022-12","updated_at":"2026-11-19T03:10:38Z","subjects":["Energy Storage System","Energy Transition","Multi-Criteria Decision-Making","Optimal Power Flow","Spatial and Temporal Analysis"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/t48m-6d57"],"render_values":[{"text":"https://doi.org/10.7298/t48m-6d57","href":"https://doi.org/10.7298/t48m-6d57","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15644103"],"render_values":[{"text":"15644103","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11638","ProQuest Publication ID: 30242047"],"render_values":[{"text":"ProQuest Submission ID: 11638","href":null,"code":true},{"text":"ProQuest Publication ID: 30242047","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/113021","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/113021","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F113021","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["You, Fengqi"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Anderson, Catherine"]},{"key":"dc:creator","label":"Author","values":["Huang, Wei-Chieh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-03-31T16:40:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-03-31T16:40:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-12"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/15644103"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Energy Storage System","Energy Transition","Multi-Criteria Decision-Making","Optimal Power Flow","Spatial and Temporal Analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["15644103"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/t48m-6d57"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11638","ProQuest Publication ID: 30242047"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/113021"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"74c66658-7e27-438d-8dd5-3685a31b1720\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>IMPACTS OF SCALABLE ENERGY STORAGE SYSTEM TECHNOLOGIES AND RENEWABLE ENERGY INTEGRATION ON THE RENEWABLE ENERGY TRANSITION IN THE NEW YORK STATE</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-12</PublicationDate> <DOI>https://doi.org/10.7298/t48m-6d57</DOI> <Authors> <Author> <DisplayName>Huang, Wei-Chieh</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Energy Storage System</Keyword> <Keyword>Energy Transition</Keyword> <Keyword>Multi-Criteria Decision-Making</Keyword> <Keyword>Optimal Power Flow</Keyword> <Keyword>Spatial and Temporal Analysis</Keyword> <Abstract>In light of current energy policies responding to rapid climate change, much attention has been directed to developing feasible approaches for transitioning energy production from fossil-based resources to renewable energy (RE). Although existing studies analyze RE's regional dispatch and capacity planning, they do not fully explore the impacts of the energy storage system (ESS) technology's technical and economic characteristics on RE integration and energy transition. To fill this gap, we propose an integrated optimal power flow and multiple criteria decision-making model (OPF-MCDM) to minimize system cost under operational constraints and evaluate the operational performance of ESS technologies with multiple criteria. Through analysis of hundreds of scenarios, the proposed method can identify the most critical features of ESS technologies to enhance RE integration and achieve New York State's climate goals from 2025 to 2040. For example, we discover that hydrogen energy storage (HES), with the highest energy loss values, requires greater installed capacities (7,419 MW of RE and 398 MW of ESS) than the lithium-ion battery (LIB) in 2040 and generates 4.2% more carbon dioxide emissions than LIB on average. Based on the cross-sensitivity analysis in the multidimensional evaluation, underground compressed air energy storage (CAES) performs the best, and HES performs the worst when reaching zero carbon dioxide emissions target in 2040. The proposed OPF-MCDM’s results can also be conveniently generalized to select ESS technology based on the criteria preferences from RE integration and energy transition studies and serve as a reference for ESS configurations in future energy and power system planning.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Huang, Wei-Chieh"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["78 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["In light of current energy policies responding to rapid climate change, much attention has been directed to developing feasible approaches for transitioning energy production from fossil-based resources to renewable energy (RE). Although existing studies analyze RE's regional dispatch and capacity planning, they do not fully explore the impacts of the energy storage system (ESS) technology's technical and economic characteristics on RE integration and energy transition. To fill this gap, we propose an integrated optimal power flow and multiple criteria decision-making model (OPF-MCDM) to minimize system cost under operational constraints and evaluate the operational performance of ESS technologies with multiple criteria. Through analysis of hundreds of scenarios, the proposed method can identify the most critical features of ESS technologies to enhance RE integration and achieve New York State's climate goals from 2025 to 2040. For example, we discover that hydrogen energy storage (HES), with the highest energy loss values, requires greater installed capacities (7,419 MW of RE and 398 MW of ESS) than the lithium-ion battery (LIB) in 2040 and generates 4.2% more carbon dioxide emissions than LIB on average. Based on the cross-sensitivity analysis in the multidimensional evaluation, underground compressed air energy storage (CAES) performs the best, and HES performs the worst when reaching zero carbon dioxide emissions target in 2040. The proposed OPF-MCDM’s results can also be conveniently generalized to select ESS technology based on the criteria preferences from RE integration and energy transition studies and serve as a reference for ESS configurations in future energy and power system planning."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["IMPACTS OF SCALABLE ENERGY STORAGE SYSTEM TECHNOLOGIES AND RENEWABLE ENERGY INTEGRATION ON THE RENEWABLE ENERGY TRANSITION IN THE NEW YORK STATE"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"74c66658-7e27-438d-8dd5-3685a31b1720\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>IMPACTS OF SCALABLE ENERGY STORAGE SYSTEM TECHNOLOGIES AND RENEWABLE ENERGY INTEGRATION ON THE RENEWABLE ENERGY TRANSITION IN THE NEW YORK STATE</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-12</PublicationDate> <DOI>https://doi.org/10.7298/t48m-6d57</DOI> <Authors> <Author> <DisplayName>Huang, Wei-Chieh</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Energy Storage System</Keyword> <Keyword>Energy Transition</Keyword> <Keyword>Multi-Criteria Decision-Making</Keyword> <Keyword>Optimal Power Flow</Keyword> <Keyword>Spatial and Temporal Analysis</Keyword> <Abstract>In light of current energy policies responding to rapid climate change, much attention has been directed to developing feasible approaches for transitioning energy production from fossil-based resources to renewable energy (RE). Although existing studies analyze RE's regional dispatch and capacity planning, they do not fully explore the impacts of the energy storage system (ESS) technology's technical and economic characteristics on RE integration and energy transition. To fill this gap, we propose an integrated optimal power flow and multiple criteria decision-making model (OPF-MCDM) to minimize system cost under operational constraints and evaluate the operational performance of ESS technologies with multiple criteria. Through analysis of hundreds of scenarios, the proposed method can identify the most critical features of ESS technologies to enhance RE integration and achieve New York State's climate goals from 2025 to 2040. For example, we discover that hydrogen energy storage (HES), with the highest energy loss values, requires greater installed capacities (7,419 MW of RE and 398 MW of ESS) than the lithium-ion battery (LIB) in 2040 and generates 4.2% more carbon dioxide emissions than LIB on average. Based on the cross-sensitivity analysis in the multidimensional evaluation, underground compressed air energy storage (CAES) performs the best, and HES performs the worst when reaching zero carbon dioxide emissions target in 2040. The proposed OPF-MCDM’s results can also be conveniently generalized to select ESS technology based on the criteria preferences from RE integration and energy transition studies and serve as a reference for ESS configurations in future energy and power system planning.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Huang, Wei-Chieh"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["You, Fengqi"],"dc:contributor.committeemember":["Anderson, Catherine"],"dc:creator":["Huang, Wei-Chieh"],"dc:date.accessioned":["2023-03-31T16:40:26Z"],"dc:date.available":["2023-03-31T16:40:26Z"],"dc:date.issued":["2022-12"],"dc:description":["78 pages"],"dc:description.abstract":["In light of current energy policies responding to rapid climate change, much attention has been directed to developing feasible approaches for transitioning energy production from fossil-based resources to renewable energy (RE). Although existing studies analyze RE's regional dispatch and capacity planning, they do not fully explore the impacts of the energy storage system (ESS) technology's technical and economic characteristics on RE integration and energy transition. To fill this gap, we propose an integrated optimal power flow and multiple criteria decision-making model (OPF-MCDM) to minimize system cost under operational constraints and evaluate the operational performance of ESS technologies with multiple criteria. Through analysis of hundreds of scenarios, the proposed method can identify the most critical features of ESS technologies to enhance RE integration and achieve New York State's climate goals from 2025 to 2040. For example, we discover that hydrogen energy storage (HES), with the highest energy loss values, requires greater installed capacities (7,419 MW of RE and 398 MW of ESS) than the lithium-ion battery (LIB) in 2040 and generates 4.2% more carbon dioxide emissions than LIB on average. Based on the cross-sensitivity analysis in the multidimensional evaluation, underground compressed air energy storage (CAES) performs the best, and HES performs the worst when reaching zero carbon dioxide emissions target in 2040. The proposed OPF-MCDM’s results can also be conveniently generalized to select ESS technology based on the criteria preferences from RE integration and energy transition studies and serve as a reference for ESS configurations in future energy and power system planning."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["15644103"],"dc:identifier.doi":["https://doi.org/10.7298/t48m-6d57"],"dc:identifier.other":["ProQuest Submission ID: 11638","ProQuest Publication ID: 30242047"],"dc:identifier.uri":["https://hdl.handle.net/1813/113021"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/15644103"],"dc:subject":["Energy Storage System","Energy Transition","Multi-Criteria Decision-Making","Optimal Power Flow","Spatial and Temporal Analysis"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["IMPACTS OF SCALABLE ENERGY STORAGE SYSTEM TECHNOLOGIES AND RENEWABLE ENERGY INTEGRATION ON THE RENEWABLE ENERGY TRANSITION IN THE NEW YORK STATE"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Systems Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Systems Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:10:38Z"}