{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/113988"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/113988","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"RAPID, REPEATABLE, AND ROBUST ANALYSIS OF TRACE LEVEL VOLATILE ORGANIC COMPOUNDS USING PLANAR HEADSPACE EXTRACTION GEOMETRIES COUPLED TO CHROMATOGRAPHY-FREE AMBIENT IONIZATION-MASS SPECTROMETRY: SOLID PHASE MICROEXTRACTION SHEETS AND BEYOND","abstract":"The routine analysis of trace-level volatile (VOCs) and semi-volatile organic (SVOCs) compounds by gas chromatography – mass spectrometry (GC-MS) is relied on by many fields for simple detection, routine profiling, and quantitation of analytes with varying physicochemical properties. Conventional GC-MS relies on extraction geometries and separations not well suited for high-throughput analyses. This work describes the development and validation of rapid methods for key trace level aroma compounds from food matrices. Planar thin film microextraction devices (e.g., Solid Phase Mesh Enhanced Sorption from Head Space (SPMESH)) allow for parallelized extractions leading to substantial improvements in throughput compared to conventional approaches. Such extraction geometries are easily coupled to ambient ionization-mass spectrometry (AI-MS) for quantitative analysis, leading to further increases to throughput by eliminating chromatographic separation prior to identification. Direct HS analysis requires sufficient volatility and physicochemical properties amenable to both extraction by the extractive phase and to ambient ionization (AI) techniques. Current SPMESH approaches are limited to highly hydrophobic polydimethylsilicone (PDMS) as an extractive phase. This work demonstrates and validates the direct analysis of a volatile, low-polarity odorant (3-isobutyl-2-methoxypyrazine (IBMP)) using SPMESH extraction followed by AI coupled to multiple detector platforms (e.g., High resolution MS, triple quadrupole MS) in around 2 min per sample. The linearity, repeatability, and limits of detection for this method demonstrate it as a good alternative to traditional chromatography-based approaches that require between 30 and 60 minutes per sample. For analysis of polar and reactive analytes (aldehyde, volatile phenols) in-situ derivatization prior to SPMESH-DART-MS was demonstrated for the first time. Derivatization with O-2,3,4,5,6-pentafluorohydroxylamine (PFBHA) is performed for C6 aldehydes (hexanal, (E)-2-hexenal) with linearity, repeatability, limits of detection, and accuracy comparable to conventional methods. For volatile phenols, a deuterated acetylation agent (d6-acetic anhydride) increased sensitivity and resolved isobaric interferences- a common challenge in chromatography free analysis methods- present in non-labelled acetylated derivatives.","abstract_html":"The routine analysis of trace-level volatile (VOCs) and semi-volatile organic (SVOCs) compounds by gas chromatography – mass spectrometry (GC-MS) is relied on by many fields for simple detection, routine profiling, and quantitation of analytes with varying physicochemical properties. Conventional GC-MS relies on extraction geometries and separations not well suited for high-throughput analyses. This work describes the development and validation of rapid methods for key trace level aroma compounds from food matrices. Planar thin film microextraction devices (e.g., Solid Phase Mesh Enhanced Sorption from Head Space (SPMESH)) allow for parallelized extractions leading to substantial improvements in throughput compared to conventional approaches. Such extraction geometries are easily coupled to ambient ionization-mass spectrometry (AI-MS) for quantitative analysis, leading to further increases to throughput by eliminating chromatographic separation prior to identification. Direct HS analysis requires sufficient volatility and physicochemical properties amenable to both extraction by the extractive phase and to ambient ionization (AI) techniques. Current SPMESH approaches are limited to highly hydrophobic polydimethylsilicone (PDMS) as an extractive phase. This work demonstrates and validates the direct analysis of a volatile, low-polarity odorant (3-isobutyl-2-methoxypyrazine (IBMP)) using SPMESH extraction followed by AI coupled to multiple detector platforms (e.g., High resolution MS, triple quadrupole MS) in around 2 min per sample. The linearity, repeatability, and limits of detection for this method demonstrate it as a good alternative to traditional chromatography-based approaches that require between 30 and 60 minutes per sample. For analysis of polar and reactive analytes (aldehyde, volatile phenols) in-situ derivatization prior to SPMESH-DART-MS was demonstrated for the first time. Derivatization with O-2,3,4,5,6-pentafluorohydroxylamine (PFBHA) is performed for C6 aldehydes (hexanal, (E)-2-hexenal) with linearity, repeatability, limits of detection, and accuracy comparable to conventional methods. For volatile phenols, a deuterated acetylation agent (d6-acetic anhydride) increased sensitivity and resolved isobaric interferences- a common challenge in chromatography free analysis methods- present in non-labelled acetylated derivatives.","abstract_has_math":false,"creators":["Bates, Terry"],"institution":"Cornell University","degree_name":"Ph. D., Food Science and Technology","degree_level":"Doctor of Philosophy","degree_discipline":"Food Science and Technology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Sacks, Gavin"],"committee_members":["Nugen, Sam","Cadle-Davidson, Lance"],"year":2023,"date_issued":"2023-05","date_published":"2023-05","updated_at":"2026-11-19T03:10:38Z","subjects":["Ambient ionization","DART Ionization","derivitization","mass spectrometry","SPMESH","Volatile compounds"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/0k84-c037"],"render_values":[{"text":"https://doi.org/10.7298/0k84-c037","href":"https://doi.org/10.7298/0k84-c037","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16176547"],"render_values":[{"text":"16176547","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 13497","ProQuest Publication ID: 30311081"],"render_values":[{"text":"ProQuest Submission ID: 13497","href":null,"code":true},{"text":"ProQuest Publication ID: 30311081","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/113988","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/113988","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F113988","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Sacks, Gavin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Nugen, Sam","Cadle-Davidson, Lance"]},{"key":"dc:creator","label":"Author","values":["Bates, Terry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-31T21:18:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-31T21:18:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/16176547"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Food Science and Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Food Science and Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ambient ionization","DART Ionization","derivitization","mass spectrometry","SPMESH","Volatile compounds"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16176547"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/0k84-c037"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 13497","ProQuest Publication ID: 30311081"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/113988"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a1e63a6d-cc99-41f0-b4c1-0824a548b65f\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>RAPID, REPEATABLE, AND ROBUST ANALYSIS OF TRACE LEVEL VOLATILE ORGANIC COMPOUNDS USING PLANAR HEADSPACE EXTRACTION GEOMETRIES COUPLED TO CHROMATOGRAPHY-FREE AMBIENT IONIZATION-MASS SPECTROMETRY: SOLID PHASE MICROEXTRACTION SHEETS AND BEYOND</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-05</PublicationDate> <DOI>https://doi.org/10.7298/0k84-c037</DOI> <Authors> <Author> <DisplayName>Bates, Terry</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Ambient ionization</Keyword> <Keyword>DART Ionization</Keyword> <Keyword>derivitization</Keyword> <Keyword>mass spectrometry</Keyword> <Keyword>SPMESH</Keyword> <Keyword>Volatile compounds</Keyword> <Abstract>The routine analysis of trace-level volatile (VOCs) and semi-volatile organic (SVOCs) compounds by gas chromatography – mass spectrometry (GC-MS) is relied on by many fields for simple detection, routine profiling, and quantitation of analytes with varying physicochemical properties. Conventional GC-MS relies on extraction geometries and separations not well suited for high-throughput analyses. This work describes the development and validation of rapid methods for key trace level aroma compounds from food matrices. Planar thin film microextraction devices (e.g., Solid Phase Mesh Enhanced Sorption from Head Space (SPMESH)) allow for parallelized extractions leading to substantial improvements in throughput compared to conventional approaches. Such extraction geometries are easily coupled to ambient ionization-mass spectrometry (AI-MS) for quantitative analysis, leading to further increases to throughput by eliminating chromatographic separation prior to identification. Direct HS analysis requires sufficient volatility and physicochemical properties amenable to both extraction by the extractive phase and to ambient ionization (AI) techniques. Current SPMESH approaches are limited to highly hydrophobic polydimethylsilicone (PDMS) as an extractive phase. This work demonstrates and validates the direct analysis of a volatile, low-polarity odorant (3-isobutyl-2-methoxypyrazine (IBMP)) using SPMESH extraction followed by AI coupled to multiple detector platforms (e.g., High resolution MS, triple quadrupole MS) in around 2 min per sample. The linearity, repeatability, and limits of detection for this method demonstrate it as a good alternative to traditional chromatography-based approaches that require between 30 and 60 minutes per sample. For analysis of polar and reactive analytes (aldehyde, volatile phenols) in-situ derivatization prior to SPMESH-DART-MS was demonstrated for the first time. Derivatization with O-2,3,4,5,6-pentafluorohydroxylamine (PFBHA) is performed for C6 aldehydes (hexanal, (E)-2-hexenal) with linearity, repeatability, limits of detection, and accuracy comparable to conventional methods. For volatile phenols, a deuterated acetylation agent (d6-acetic anhydride) increased sensitivity and resolved isobaric interferences- a common challenge in chromatography free analysis methods- present in non-labelled acetylated derivatives.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Bates, Terry"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["The routine analysis of trace-level volatile (VOCs) and semi-volatile organic (SVOCs) compounds by gas chromatography – mass spectrometry (GC-MS) is relied on by many fields for simple detection, routine profiling, and quantitation of analytes with varying physicochemical properties. Conventional GC-MS relies on extraction geometries and separations not well suited for high-throughput analyses. This work describes the development and validation of rapid methods for key trace level aroma compounds from food matrices. Planar thin film microextraction devices (e.g., Solid Phase Mesh Enhanced Sorption from Head Space (SPMESH)) allow for parallelized extractions leading to substantial improvements in throughput compared to conventional approaches. Such extraction geometries are easily coupled to ambient ionization-mass spectrometry (AI-MS) for quantitative analysis, leading to further increases to throughput by eliminating chromatographic separation prior to identification. Direct HS analysis requires sufficient volatility and physicochemical properties amenable to both extraction by the extractive phase and to ambient ionization (AI) techniques. Current SPMESH approaches are limited to highly hydrophobic polydimethylsilicone (PDMS) as an extractive phase. This work demonstrates and validates the direct analysis of a volatile, low-polarity odorant (3-isobutyl-2-methoxypyrazine (IBMP)) using SPMESH extraction followed by AI coupled to multiple detector platforms (e.g., High resolution MS, triple quadrupole MS) in around 2 min per sample. The linearity, repeatability, and limits of detection for this method demonstrate it as a good alternative to traditional chromatography-based approaches that require between 30 and 60 minutes per sample. For analysis of polar and reactive analytes (aldehyde, volatile phenols) in-situ derivatization prior to SPMESH-DART-MS was demonstrated for the first time. Derivatization with O-2,3,4,5,6-pentafluorohydroxylamine (PFBHA) is performed for C6 aldehydes (hexanal, (E)-2-hexenal) with linearity, repeatability, limits of detection, and accuracy comparable to conventional methods. For volatile phenols, a deuterated acetylation agent (d6-acetic anhydride) increased sensitivity and resolved isobaric interferences- a common challenge in chromatography free analysis methods- present in non-labelled acetylated derivatives."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["RAPID, REPEATABLE, AND ROBUST ANALYSIS OF TRACE LEVEL VOLATILE ORGANIC COMPOUNDS USING PLANAR HEADSPACE EXTRACTION GEOMETRIES COUPLED TO CHROMATOGRAPHY-FREE AMBIENT IONIZATION-MASS SPECTROMETRY: SOLID PHASE MICROEXTRACTION SHEETS AND BEYOND"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a1e63a6d-cc99-41f0-b4c1-0824a548b65f\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>RAPID, REPEATABLE, AND ROBUST ANALYSIS OF TRACE LEVEL VOLATILE ORGANIC COMPOUNDS USING PLANAR HEADSPACE EXTRACTION GEOMETRIES COUPLED TO CHROMATOGRAPHY-FREE AMBIENT IONIZATION-MASS SPECTROMETRY: SOLID PHASE MICROEXTRACTION SHEETS AND BEYOND</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-05</PublicationDate> <DOI>https://doi.org/10.7298/0k84-c037</DOI> <Authors> <Author> <DisplayName>Bates, Terry</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Ambient ionization</Keyword> <Keyword>DART Ionization</Keyword> <Keyword>derivitization</Keyword> <Keyword>mass spectrometry</Keyword> <Keyword>SPMESH</Keyword> <Keyword>Volatile compounds</Keyword> <Abstract>The routine analysis of trace-level volatile (VOCs) and semi-volatile organic (SVOCs) compounds by gas chromatography – mass spectrometry (GC-MS) is relied on by many fields for simple detection, routine profiling, and quantitation of analytes with varying physicochemical properties. Conventional GC-MS relies on extraction geometries and separations not well suited for high-throughput analyses. This work describes the development and validation of rapid methods for key trace level aroma compounds from food matrices. Planar thin film microextraction devices (e.g., Solid Phase Mesh Enhanced Sorption from Head Space (SPMESH)) allow for parallelized extractions leading to substantial improvements in throughput compared to conventional approaches. Such extraction geometries are easily coupled to ambient ionization-mass spectrometry (AI-MS) for quantitative analysis, leading to further increases to throughput by eliminating chromatographic separation prior to identification. Direct HS analysis requires sufficient volatility and physicochemical properties amenable to both extraction by the extractive phase and to ambient ionization (AI) techniques. Current SPMESH approaches are limited to highly hydrophobic polydimethylsilicone (PDMS) as an extractive phase. This work demonstrates and validates the direct analysis of a volatile, low-polarity odorant (3-isobutyl-2-methoxypyrazine (IBMP)) using SPMESH extraction followed by AI coupled to multiple detector platforms (e.g., High resolution MS, triple quadrupole MS) in around 2 min per sample. The linearity, repeatability, and limits of detection for this method demonstrate it as a good alternative to traditional chromatography-based approaches that require between 30 and 60 minutes per sample. For analysis of polar and reactive analytes (aldehyde, volatile phenols) in-situ derivatization prior to SPMESH-DART-MS was demonstrated for the first time. Derivatization with O-2,3,4,5,6-pentafluorohydroxylamine (PFBHA) is performed for C6 aldehydes (hexanal, (E)-2-hexenal) with linearity, repeatability, limits of detection, and accuracy comparable to conventional methods. For volatile phenols, a deuterated acetylation agent (d6-acetic anhydride) increased sensitivity and resolved isobaric interferences- a common challenge in chromatography free analysis methods- present in non-labelled acetylated derivatives.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Bates, Terry"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Sacks, Gavin"],"dc:contributor.committeemember":["Nugen, Sam","Cadle-Davidson, Lance"],"dc:creator":["Bates, Terry"],"dc:date.accessioned":["2024-01-31T21:18:31Z"],"dc:date.available":["2024-01-31T21:18:31Z"],"dc:date.issued":["2023-05"],"dc:description.abstract":["The routine analysis of trace-level volatile (VOCs) and semi-volatile organic (SVOCs) compounds by gas chromatography – mass spectrometry (GC-MS) is relied on by many fields for simple detection, routine profiling, and quantitation of analytes with varying physicochemical properties. Conventional GC-MS relies on extraction geometries and separations not well suited for high-throughput analyses. This work describes the development and validation of rapid methods for key trace level aroma compounds from food matrices. Planar thin film microextraction devices (e.g., Solid Phase Mesh Enhanced Sorption from Head Space (SPMESH)) allow for parallelized extractions leading to substantial improvements in throughput compared to conventional approaches. Such extraction geometries are easily coupled to ambient ionization-mass spectrometry (AI-MS) for quantitative analysis, leading to further increases to throughput by eliminating chromatographic separation prior to identification. Direct HS analysis requires sufficient volatility and physicochemical properties amenable to both extraction by the extractive phase and to ambient ionization (AI) techniques. Current SPMESH approaches are limited to highly hydrophobic polydimethylsilicone (PDMS) as an extractive phase. This work demonstrates and validates the direct analysis of a volatile, low-polarity odorant (3-isobutyl-2-methoxypyrazine (IBMP)) using SPMESH extraction followed by AI coupled to multiple detector platforms (e.g., High resolution MS, triple quadrupole MS) in around 2 min per sample. The linearity, repeatability, and limits of detection for this method demonstrate it as a good alternative to traditional chromatography-based approaches that require between 30 and 60 minutes per sample. For analysis of polar and reactive analytes (aldehyde, volatile phenols) in-situ derivatization prior to SPMESH-DART-MS was demonstrated for the first time. Derivatization with O-2,3,4,5,6-pentafluorohydroxylamine (PFBHA) is performed for C6 aldehydes (hexanal, (E)-2-hexenal) with linearity, repeatability, limits of detection, and accuracy comparable to conventional methods. For volatile phenols, a deuterated acetylation agent (d6-acetic anhydride) increased sensitivity and resolved isobaric interferences- a common challenge in chromatography free analysis methods- present in non-labelled acetylated derivatives."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["16176547"],"dc:identifier.doi":["https://doi.org/10.7298/0k84-c037"],"dc:identifier.other":["ProQuest Submission ID: 13497","ProQuest Publication ID: 30311081"],"dc:identifier.uri":["https://hdl.handle.net/1813/113988"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/16176547"],"dc:subject":["Ambient ionization","DART Ionization","derivitization","mass spectrometry","SPMESH","Volatile compounds"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["RAPID, REPEATABLE, AND ROBUST ANALYSIS OF TRACE LEVEL VOLATILE ORGANIC COMPOUNDS USING PLANAR HEADSPACE EXTRACTION GEOMETRIES COUPLED TO CHROMATOGRAPHY-FREE AMBIENT IONIZATION-MASS SPECTROMETRY: SOLID PHASE MICROEXTRACTION SHEETS AND BEYOND"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Food Science and Technology"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Food Science and Technology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:10:38Z"}