{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/114130"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/114130","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"UNDERSTANDING BLEEDING, THROMBOSIS, AND STROKE RISKS ASSOCIATED WITH PEDIATRIC AND ADULT VENTRICULAR ASSIST DEVICE PATIENTS THROUGH MULTIPLE MECHANISMS","abstract":"For over 50 years, continuous flow ventricular assist devices (VADs) have greatly improved the longevity and quality of life of end-stage heart failure patients. However, these individuals remain at high risk for thrombosis, stroke, and gastrointestinal bleeding. Herein, this report attempts to understand and explain why these adverse events persist in both children and adults receiving a VAD despite decades of R&D. One objective was to develop a novel method of characterizing pump thrombosis in an axial-flow VAD, which can be used to better calibrate computational fluid dynamics models in blood-wetted devices. These thrombi were classified in five regions of the pump by their composition, severity, frequency, and physical distribution. There was a statistically significant correlation between thrombosis deposition on the forbearing and subsequent downstream thrombogenesis in the outlet bearing/stator region, suggesting upstream thrombosis may propagate and lead to downstream deposition.A second aim was to propose an alternative explanation for elevated stroke rates in the absence of adherent pump thrombosis; mainly, the ingestion of thrombi from the ventricle or atrial appendage. High-speed videography was used to capture the degree of disruption, adherence, and disintegration of thrombi in transparent VAD models. Although a large proportion of thrombi were macerated into infinitesimal pieces, some thromboemboli ejected from the pumps were of sufficient size to occlude an intracranial artery. Other ingested thrombi were observed physically adhering to the inner flow path, which may serve as a nidus for further thrombogenesis. A third objective was to explain the differences in non-surgical bleeding rates between mechanical circulatory devices in the pediatric setting, which is commonly attributed to the mechano-enzymatic cleavage of von Willebrand factor (vWF). At a 1.5 LPM flow condition, the loss of high molecular weight vWF multimers was comparable (-7.5% and -7.9%) between the PediaFlow™, a magnetically levitated pediatric ventricular assist device, and a standard of care device (PediaMag™). The vWF: CB/Ag ratio decreased slightly in the PediaFlow™ compared to PediaMag™ (-8% vs +3%), but the results were not statistically significant. Collectively, these results support alternative hypotheses for persistent adverse events observed in both pediatric and adult VAD patients.","abstract_html":"For over 50 years, continuous flow ventricular assist devices (VADs) have greatly improved the longevity and quality of life of end-stage heart failure patients. However, these individuals remain at high risk for thrombosis, stroke, and gastrointestinal bleeding. Herein, this report attempts to understand and explain why these adverse events persist in both children and adults receiving a VAD despite decades of R&amp;D. One objective was to develop a novel method of characterizing pump thrombosis in an axial-flow VAD, which can be used to better calibrate computational fluid dynamics models in blood-wetted devices. These thrombi were classified in five regions of the pump by their composition, severity, frequency, and physical distribution. There was a statistically significant correlation between thrombosis deposition on the forbearing and subsequent downstream thrombogenesis in the outlet bearing/stator region, suggesting upstream thrombosis may propagate and lead to downstream deposition.A second aim was to propose an alternative explanation for elevated stroke rates in the absence of adherent pump thrombosis; mainly, the ingestion of thrombi from the ventricle or atrial appendage. High-speed videography was used to capture the degree of disruption, adherence, and disintegration of thrombi in transparent VAD models. Although a large proportion of thrombi were macerated into infinitesimal pieces, some thromboemboli ejected from the pumps were of sufficient size to occlude an intracranial artery. Other ingested thrombi were observed physically adhering to the inner flow path, which may serve as a nidus for further thrombogenesis. A third objective was to explain the differences in non-surgical bleeding rates between mechanical circulatory devices in the pediatric setting, which is commonly attributed to the mechano-enzymatic cleavage of von Willebrand factor (vWF). At a 1.5 LPM flow condition, the loss of high molecular weight vWF multimers was comparable (-7.5% and -7.9%) between the PediaFlow™, a magnetically levitated pediatric ventricular assist device, and a standard of care device (PediaMag™). The vWF: CB/Ag ratio decreased slightly in the PediaFlow™ compared to PediaMag™ (-8% vs +3%), but the results were not statistically significant. Collectively, these results support alternative hypotheses for persistent adverse events observed in both pediatric and adult VAD patients.","abstract_has_math":false,"creators":["Rowlands, Grant"],"institution":"Cornell University","degree_name":"Ph. D., Biomedical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Antaki, James"],"committee_members":["Butcher, Jonathan","Kirby, Brian"],"year":2023,"date_issued":"2023-05","date_published":"2023-05","updated_at":"2026-11-19T03:10:38Z","subjects":["hemodynamics","mechanical circulatory support","stroke","thrombosis","ventricular assist devices","von Willebrand Factor"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/5440-f772"],"render_values":[{"text":"https://doi.org/10.7298/5440-f772","href":"https://doi.org/10.7298/5440-f772","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16176647"],"render_values":[{"text":"16176647","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 13526","ProQuest Publication ID: 30418236"],"render_values":[{"text":"ProQuest Submission ID: 13526","href":null,"code":true},{"text":"ProQuest Publication ID: 30418236","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/114130","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/114130","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F114130","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Antaki, James"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Butcher, Jonathan","Kirby, Brian"]},{"key":"dc:creator","label":"Author","values":["Rowlands, Grant"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-31T21:19:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/16176647"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["hemodynamics","mechanical circulatory support","stroke","thrombosis","ventricular assist devices","von Willebrand Factor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16176647"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/5440-f772"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 13526","ProQuest Publication ID: 30418236"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/114130"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"f203647a-38f3-41fb-95e7-140eaaed50a3\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>UNDERSTANDING BLEEDING, THROMBOSIS, AND STROKE RISKS ASSOCIATED WITH PEDIATRIC AND ADULT VENTRICULAR ASSIST DEVICE PATIENTS THROUGH MULTIPLE MECHANISMS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-05</PublicationDate> <DOI>https://doi.org/10.7298/5440-f772</DOI> <Authors> <Author> <DisplayName>Rowlands, Grant</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>hemodynamics</Keyword> <Keyword>mechanical circulatory support</Keyword> <Keyword>stroke</Keyword> <Keyword>thrombosis</Keyword> <Keyword>ventricular assist devices</Keyword> <Keyword>von Willebrand Factor</Keyword> <Abstract>For over 50 years, continuous flow ventricular assist devices (VADs) have greatly improved the longevity and quality of life of end-stage heart failure patients. However, these individuals remain at high risk for thrombosis, stroke, and gastrointestinal bleeding. Herein, this report attempts to understand and explain why these adverse events persist in both children and adults receiving a VAD despite decades of R&D. One objective was to develop a novel method of characterizing pump thrombosis in an axial-flow VAD, which can be used to better calibrate computational fluid dynamics models in blood-wetted devices. These thrombi were classified in five regions of the pump by their composition, severity, frequency, and physical distribution. There was a statistically significant correlation between thrombosis deposition on the forbearing and subsequent downstream thrombogenesis in the outlet bearing/stator region, suggesting upstream thrombosis may propagate and lead to downstream deposition.A second aim was to propose an alternative explanation for elevated stroke rates in the absence of adherent pump thrombosis; mainly, the ingestion of thrombi from the ventricle or atrial appendage. High-speed videography was used to capture the degree of disruption, adherence, and disintegration of thrombi in transparent VAD models. Although a large proportion of thrombi were macerated into infinitesimal pieces, some thromboemboli ejected from the pumps were of sufficient size to occlude an intracranial artery. Other ingested thrombi were observed physically adhering to the inner flow path, which may serve as a nidus for further thrombogenesis. A third objective was to explain the differences in non-surgical bleeding rates between mechanical circulatory devices in the pediatric setting, which is commonly attributed to the mechano-enzymatic cleavage of von Willebrand factor (vWF). At a 1.5 LPM flow condition, the loss of high molecular weight vWF multimers was comparable (-7.5% and -7.9%) between the PediaFlow™, a magnetically levitated pediatric ventricular assist device, and a standard of care device (PediaMag™). The vWF: CB/Ag ratio decreased slightly in the PediaFlow™ compared to PediaMag™ (-8% vs +3%), but the results were not statistically significant. Collectively, these results support alternative hypotheses for persistent adverse events observed in both pediatric and adult VAD patients.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Rowlands, Grant"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["For over 50 years, continuous flow ventricular assist devices (VADs) have greatly improved the longevity and quality of life of end-stage heart failure patients. However, these individuals remain at high risk for thrombosis, stroke, and gastrointestinal bleeding. Herein, this report attempts to understand and explain why these adverse events persist in both children and adults receiving a VAD despite decades of R&D. One objective was to develop a novel method of characterizing pump thrombosis in an axial-flow VAD, which can be used to better calibrate computational fluid dynamics models in blood-wetted devices. These thrombi were classified in five regions of the pump by their composition, severity, frequency, and physical distribution. There was a statistically significant correlation between thrombosis deposition on the forbearing and subsequent downstream thrombogenesis in the outlet bearing/stator region, suggesting upstream thrombosis may propagate and lead to downstream deposition.A second aim was to propose an alternative explanation for elevated stroke rates in the absence of adherent pump thrombosis; mainly, the ingestion of thrombi from the ventricle or atrial appendage. High-speed videography was used to capture the degree of disruption, adherence, and disintegration of thrombi in transparent VAD models. Although a large proportion of thrombi were macerated into infinitesimal pieces, some thromboemboli ejected from the pumps were of sufficient size to occlude an intracranial artery. Other ingested thrombi were observed physically adhering to the inner flow path, which may serve as a nidus for further thrombogenesis. A third objective was to explain the differences in non-surgical bleeding rates between mechanical circulatory devices in the pediatric setting, which is commonly attributed to the mechano-enzymatic cleavage of von Willebrand factor (vWF). At a 1.5 LPM flow condition, the loss of high molecular weight vWF multimers was comparable (-7.5% and -7.9%) between the PediaFlow™, a magnetically levitated pediatric ventricular assist device, and a standard of care device (PediaMag™). The vWF: CB/Ag ratio decreased slightly in the PediaFlow™ compared to PediaMag™ (-8% vs +3%), but the results were not statistically significant. Collectively, these results support alternative hypotheses for persistent adverse events observed in both pediatric and adult VAD patients."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["UNDERSTANDING BLEEDING, THROMBOSIS, AND STROKE RISKS ASSOCIATED WITH PEDIATRIC AND ADULT VENTRICULAR ASSIST DEVICE PATIENTS THROUGH MULTIPLE MECHANISMS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"f203647a-38f3-41fb-95e7-140eaaed50a3\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>UNDERSTANDING BLEEDING, THROMBOSIS, AND STROKE RISKS ASSOCIATED WITH PEDIATRIC AND ADULT VENTRICULAR ASSIST DEVICE PATIENTS THROUGH MULTIPLE MECHANISMS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-05</PublicationDate> <DOI>https://doi.org/10.7298/5440-f772</DOI> <Authors> <Author> <DisplayName>Rowlands, Grant</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>hemodynamics</Keyword> <Keyword>mechanical circulatory support</Keyword> <Keyword>stroke</Keyword> <Keyword>thrombosis</Keyword> <Keyword>ventricular assist devices</Keyword> <Keyword>von Willebrand Factor</Keyword> <Abstract>For over 50 years, continuous flow ventricular assist devices (VADs) have greatly improved the longevity and quality of life of end-stage heart failure patients. However, these individuals remain at high risk for thrombosis, stroke, and gastrointestinal bleeding. Herein, this report attempts to understand and explain why these adverse events persist in both children and adults receiving a VAD despite decades of R&D. One objective was to develop a novel method of characterizing pump thrombosis in an axial-flow VAD, which can be used to better calibrate computational fluid dynamics models in blood-wetted devices. These thrombi were classified in five regions of the pump by their composition, severity, frequency, and physical distribution. There was a statistically significant correlation between thrombosis deposition on the forbearing and subsequent downstream thrombogenesis in the outlet bearing/stator region, suggesting upstream thrombosis may propagate and lead to downstream deposition.A second aim was to propose an alternative explanation for elevated stroke rates in the absence of adherent pump thrombosis; mainly, the ingestion of thrombi from the ventricle or atrial appendage. High-speed videography was used to capture the degree of disruption, adherence, and disintegration of thrombi in transparent VAD models. Although a large proportion of thrombi were macerated into infinitesimal pieces, some thromboemboli ejected from the pumps were of sufficient size to occlude an intracranial artery. Other ingested thrombi were observed physically adhering to the inner flow path, which may serve as a nidus for further thrombogenesis. A third objective was to explain the differences in non-surgical bleeding rates between mechanical circulatory devices in the pediatric setting, which is commonly attributed to the mechano-enzymatic cleavage of von Willebrand factor (vWF). At a 1.5 LPM flow condition, the loss of high molecular weight vWF multimers was comparable (-7.5% and -7.9%) between the PediaFlow™, a magnetically levitated pediatric ventricular assist device, and a standard of care device (PediaMag™). The vWF: CB/Ag ratio decreased slightly in the PediaFlow™ compared to PediaMag™ (-8% vs +3%), but the results were not statistically significant. Collectively, these results support alternative hypotheses for persistent adverse events observed in both pediatric and adult VAD patients.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Rowlands, Grant"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Antaki, James"],"dc:contributor.committeemember":["Butcher, Jonathan","Kirby, Brian"],"dc:creator":["Rowlands, Grant"],"dc:date.accessioned":["2024-01-31T21:19:46Z"],"dc:date.issued":["2023-05"],"dc:description.abstract":["For over 50 years, continuous flow ventricular assist devices (VADs) have greatly improved the longevity and quality of life of end-stage heart failure patients. However, these individuals remain at high risk for thrombosis, stroke, and gastrointestinal bleeding. Herein, this report attempts to understand and explain why these adverse events persist in both children and adults receiving a VAD despite decades of R&D. One objective was to develop a novel method of characterizing pump thrombosis in an axial-flow VAD, which can be used to better calibrate computational fluid dynamics models in blood-wetted devices. These thrombi were classified in five regions of the pump by their composition, severity, frequency, and physical distribution. There was a statistically significant correlation between thrombosis deposition on the forbearing and subsequent downstream thrombogenesis in the outlet bearing/stator region, suggesting upstream thrombosis may propagate and lead to downstream deposition.A second aim was to propose an alternative explanation for elevated stroke rates in the absence of adherent pump thrombosis; mainly, the ingestion of thrombi from the ventricle or atrial appendage. High-speed videography was used to capture the degree of disruption, adherence, and disintegration of thrombi in transparent VAD models. Although a large proportion of thrombi were macerated into infinitesimal pieces, some thromboemboli ejected from the pumps were of sufficient size to occlude an intracranial artery. Other ingested thrombi were observed physically adhering to the inner flow path, which may serve as a nidus for further thrombogenesis. A third objective was to explain the differences in non-surgical bleeding rates between mechanical circulatory devices in the pediatric setting, which is commonly attributed to the mechano-enzymatic cleavage of von Willebrand factor (vWF). At a 1.5 LPM flow condition, the loss of high molecular weight vWF multimers was comparable (-7.5% and -7.9%) between the PediaFlow™, a magnetically levitated pediatric ventricular assist device, and a standard of care device (PediaMag™). The vWF: CB/Ag ratio decreased slightly in the PediaFlow™ compared to PediaMag™ (-8% vs +3%), but the results were not statistically significant. Collectively, these results support alternative hypotheses for persistent adverse events observed in both pediatric and adult VAD patients."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["16176647"],"dc:identifier.doi":["https://doi.org/10.7298/5440-f772"],"dc:identifier.other":["ProQuest Submission ID: 13526","ProQuest Publication ID: 30418236"],"dc:identifier.uri":["https://hdl.handle.net/1813/114130"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/16176647"],"dc:subject":["hemodynamics","mechanical circulatory support","stroke","thrombosis","ventricular assist devices","von Willebrand Factor"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["UNDERSTANDING BLEEDING, THROMBOSIS, AND STROKE RISKS ASSOCIATED WITH PEDIATRIC AND ADULT VENTRICULAR ASSIST DEVICE PATIENTS THROUGH MULTIPLE MECHANISMS"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Biomedical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:10:38Z"}