{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/114510"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/114510","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"DESIGNING BIOSENSING GENETIC CIRCUITS USING ALLOSTERIC TRANSCRIPTION FACTORS IN CELL-FREE SYSTEMS","abstract":"Allosteric transcription factors (aTF) regulate gene expression by interactingwith target effector molecules. The specificity of aTF towards their effectors can be used for biosensing purposes. Combining them with in-vitro tools such as cell-free systems can create rapid, portable, low-cost, highly sensitive biosensors. These biosensors can be deployed to target analytes such as heavy metal ions in water supplies in places that do not possess capabilities for operating costly biosensors. To this end, we constructed a cell-free biosensor capable of sensing copper in samples like wastewater, drinking water, and biological samples. The sensor element was an aTF CueR from the MerR family of transcriptional activators capable of sensing copper. A computational model based on ordinary differential equations was constructed to simulate the transcription-translation dynamics of the sensor circuit. The overall goal of the model was to explain the copper sensing by CueR aTF. Model parameters were either estimated from literature values or experimental measurements of the concentrations of mRNA and proteins of individual species in the circuit. Unknown model parameters were estimated by minimizing the difference between model simulations and the experimental data generated from this study. In conclusion, we constructed a metal ion sensor circuit based on the CueR transcription factor and a mathematical model to optimize circuit performance. A quantitative model to predict the biosensing of metal ions like copper could be used as a starting point to simulate sensor performance for copper and other ions that are detectable via the MerR family of transcription factors.","abstract_html":"Allosteric transcription factors (aTF) regulate gene expression by interactingwith target effector molecules. The specificity of aTF towards their effectors can be used for biosensing purposes. Combining them with in-vitro tools such as cell-free systems can create rapid, portable, low-cost, highly sensitive biosensors. These biosensors can be deployed to target analytes such as heavy metal ions in water supplies in places that do not possess capabilities for operating costly biosensors. To this end, we constructed a cell-free biosensor capable of sensing copper in samples like wastewater, drinking water, and biological samples. The sensor element was an aTF CueR from the MerR family of transcriptional activators capable of sensing copper. A computational model based on ordinary differential equations was constructed to simulate the transcription-translation dynamics of the sensor circuit. The overall goal of the model was to explain the copper sensing by CueR aTF. Model parameters were either estimated from literature values or experimental measurements of the concentrations of mRNA and proteins of individual species in the circuit. Unknown model parameters were estimated by minimizing the difference between model simulations and the experimental data generated from this study. In conclusion, we constructed a metal ion sensor circuit based on the CueR transcription factor and a mathematical model to optimize circuit performance. A quantitative model to predict the biosensing of metal ions like copper could be used as a starting point to simulate sensor performance for copper and other ions that are detectable via the MerR family of transcription factors.","abstract_has_math":false,"creators":["Suresh Babu, Aravind"],"institution":"Cornell University","degree_name":"M.S., Chemical Engineering","degree_level":"Master of Science","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Varner, Jeffrey"],"committee_members":["DeLisa, Matthew"],"year":2023,"date_issued":"2023-08","date_published":"2023-08","updated_at":"2026-11-19T03:10:38Z","subjects":["biosensor","cell-free","copper","CueR","mathematical model","Transcription factor"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/n29h-zb52"],"render_values":[{"text":"https://doi.org/10.7298/n29h-zb52","href":"https://doi.org/10.7298/n29h-zb52","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16219419"],"render_values":[{"text":"16219419","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11858","ProQuest Publication ID: 30571725"],"render_values":[{"text":"ProQuest Submission ID: 11858","href":null,"code":true},{"text":"ProQuest Publication ID: 30571725","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/114510","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/114510","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F114510","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Varner, Jeffrey"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["DeLisa, Matthew"]},{"key":"dc:creator","label":"Author","values":["Suresh Babu, Aravind"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-04-05T18:36:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-04-05T18:36:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-08"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/16219419"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Chemical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biosensor","cell-free","copper","CueR","mathematical model","Transcription factor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16219419"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/n29h-zb52"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11858","ProQuest Publication ID: 30571725"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/114510"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"6dd3e26d-b2eb-4bc5-88e7-684ba74942c3\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>DESIGNING BIOSENSING GENETIC CIRCUITS USING ALLOSTERIC TRANSCRIPTION FACTORS IN CELL-FREE SYSTEMS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-08</PublicationDate> <DOI>https://doi.org/10.7298/n29h-zb52</DOI> <Authors> <Author> <DisplayName>Suresh Babu, Aravind</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>biosensor</Keyword> <Keyword>cell-free</Keyword> <Keyword>copper</Keyword> <Keyword>CueR</Keyword> <Keyword>mathematical model</Keyword> <Keyword>Transcription factor</Keyword> <Abstract>Allosteric transcription factors (aTF) regulate gene expression by interactingwith target effector molecules. The specificity of aTF towards their effectors can be used for biosensing purposes. Combining them with in-vitro tools such as cell-free systems can create rapid, portable, low-cost, highly sensitive biosensors. These biosensors can be deployed to target analytes such as heavy metal ions in water supplies in places that do not possess capabilities for operating costly biosensors. To this end, we constructed a cell-free biosensor capable of sensing copper in samples like wastewater, drinking water, and biological samples. The sensor element was an aTF CueR from the MerR family of transcriptional activators capable of sensing copper. A computational model based on ordinary differential equations was constructed to simulate the transcription-translation dynamics of the sensor circuit. The overall goal of the model was to explain the copper sensing by CueR aTF. Model parameters were either estimated from literature values or experimental measurements of the concentrations of mRNA and proteins of individual species in the circuit. Unknown model parameters were estimated by minimizing the difference between model simulations and the experimental data generated from this study. In conclusion, we constructed a metal ion sensor circuit based on the CueR transcription factor and a mathematical model to optimize circuit performance. A quantitative model to predict the biosensing of metal ions like copper could be used as a starting point to simulate sensor performance for copper and other ions that are detectable via the MerR family of transcription factors.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Suresh Babu, Aravind"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["134 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Allosteric transcription factors (aTF) regulate gene expression by interactingwith target effector molecules. The specificity of aTF towards their effectors can be used for biosensing purposes. Combining them with in-vitro tools such as cell-free systems can create rapid, portable, low-cost, highly sensitive biosensors. These biosensors can be deployed to target analytes such as heavy metal ions in water supplies in places that do not possess capabilities for operating costly biosensors. To this end, we constructed a cell-free biosensor capable of sensing copper in samples like wastewater, drinking water, and biological samples. The sensor element was an aTF CueR from the MerR family of transcriptional activators capable of sensing copper. A computational model based on ordinary differential equations was constructed to simulate the transcription-translation dynamics of the sensor circuit. The overall goal of the model was to explain the copper sensing by CueR aTF. Model parameters were either estimated from literature values or experimental measurements of the concentrations of mRNA and proteins of individual species in the circuit. Unknown model parameters were estimated by minimizing the difference between model simulations and the experimental data generated from this study. In conclusion, we constructed a metal ion sensor circuit based on the CueR transcription factor and a mathematical model to optimize circuit performance. A quantitative model to predict the biosensing of metal ions like copper could be used as a starting point to simulate sensor performance for copper and other ions that are detectable via the MerR family of transcription factors."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["DESIGNING BIOSENSING GENETIC CIRCUITS USING ALLOSTERIC TRANSCRIPTION FACTORS IN CELL-FREE SYSTEMS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"6dd3e26d-b2eb-4bc5-88e7-684ba74942c3\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>DESIGNING BIOSENSING GENETIC CIRCUITS USING ALLOSTERIC TRANSCRIPTION FACTORS IN CELL-FREE SYSTEMS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-08</PublicationDate> <DOI>https://doi.org/10.7298/n29h-zb52</DOI> <Authors> <Author> <DisplayName>Suresh Babu, Aravind</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>biosensor</Keyword> <Keyword>cell-free</Keyword> <Keyword>copper</Keyword> <Keyword>CueR</Keyword> <Keyword>mathematical model</Keyword> <Keyword>Transcription factor</Keyword> <Abstract>Allosteric transcription factors (aTF) regulate gene expression by interactingwith target effector molecules. The specificity of aTF towards their effectors can be used for biosensing purposes. Combining them with in-vitro tools such as cell-free systems can create rapid, portable, low-cost, highly sensitive biosensors. These biosensors can be deployed to target analytes such as heavy metal ions in water supplies in places that do not possess capabilities for operating costly biosensors. To this end, we constructed a cell-free biosensor capable of sensing copper in samples like wastewater, drinking water, and biological samples. The sensor element was an aTF CueR from the MerR family of transcriptional activators capable of sensing copper. A computational model based on ordinary differential equations was constructed to simulate the transcription-translation dynamics of the sensor circuit. The overall goal of the model was to explain the copper sensing by CueR aTF. Model parameters were either estimated from literature values or experimental measurements of the concentrations of mRNA and proteins of individual species in the circuit. Unknown model parameters were estimated by minimizing the difference between model simulations and the experimental data generated from this study. In conclusion, we constructed a metal ion sensor circuit based on the CueR transcription factor and a mathematical model to optimize circuit performance. A quantitative model to predict the biosensing of metal ions like copper could be used as a starting point to simulate sensor performance for copper and other ions that are detectable via the MerR family of transcription factors.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Suresh Babu, Aravind"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Varner, Jeffrey"],"dc:contributor.committeemember":["DeLisa, Matthew"],"dc:creator":["Suresh Babu, Aravind"],"dc:date.accessioned":["2024-04-05T18:36:44Z"],"dc:date.available":["2024-04-05T18:36:44Z"],"dc:date.issued":["2023-08"],"dc:description":["134 pages"],"dc:description.abstract":["Allosteric transcription factors (aTF) regulate gene expression by interactingwith target effector molecules. The specificity of aTF towards their effectors can be used for biosensing purposes. Combining them with in-vitro tools such as cell-free systems can create rapid, portable, low-cost, highly sensitive biosensors. These biosensors can be deployed to target analytes such as heavy metal ions in water supplies in places that do not possess capabilities for operating costly biosensors. To this end, we constructed a cell-free biosensor capable of sensing copper in samples like wastewater, drinking water, and biological samples. The sensor element was an aTF CueR from the MerR family of transcriptional activators capable of sensing copper. A computational model based on ordinary differential equations was constructed to simulate the transcription-translation dynamics of the sensor circuit. The overall goal of the model was to explain the copper sensing by CueR aTF. Model parameters were either estimated from literature values or experimental measurements of the concentrations of mRNA and proteins of individual species in the circuit. Unknown model parameters were estimated by minimizing the difference between model simulations and the experimental data generated from this study. In conclusion, we constructed a metal ion sensor circuit based on the CueR transcription factor and a mathematical model to optimize circuit performance. A quantitative model to predict the biosensing of metal ions like copper could be used as a starting point to simulate sensor performance for copper and other ions that are detectable via the MerR family of transcription factors."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["16219419"],"dc:identifier.doi":["https://doi.org/10.7298/n29h-zb52"],"dc:identifier.other":["ProQuest Submission ID: 11858","ProQuest Publication ID: 30571725"],"dc:identifier.uri":["https://hdl.handle.net/1813/114510"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/16219419"],"dc:subject":["biosensor","cell-free","copper","CueR","mathematical model","Transcription factor"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["DESIGNING BIOSENSING GENETIC CIRCUITS USING ALLOSTERIC TRANSCRIPTION FACTORS IN CELL-FREE SYSTEMS"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Chemical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:10:38Z"}