{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/116422"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/116422","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Wearable Radio-Frequency Cardiac Sensing: Physiology, Algorithms, and Clinical Applications","abstract":"Cardiovascular disease remains the leading cause of mortality worldwide, yet effective detection, monitoring, and timely intervention can significantly improve treatment outcomes. Early identification of conditions such as arrhythmias, valvular disorders, heart failure, and hypertension is crucial for enhancing patient outcomes. However, traditional detection and diagnosis methods are often confined to in-clinic examinations, which not only incur high costs, making them inaccessible for many, but also provide only episodic insights, potentially missing symptomatic periods. A paradigm shift to continuous cardiovascular monitoring could transform healthcare delivery by offering a continuous, accessible, and convenient analysis of cardiovascular health. Near-field radiofrequency (RF) sensing technology can enable this paradigm shift, by offering continuous, real-time heart and lung motion monitoring without direct skin contact, allowing for monitoring over clothing or via furniture integration. This non-contact capability sets it apart from conventional sensing methods like electrocardiography, ultrasound/echocardiography, or photoplethysmography. This thesis explores the physiological underpinnings that correlate cardiac motion with near-field RF sensing signals, the development of specialized algorithms for processing this distinctive data, and its clinical implications for convenient and continuous monitoring. The two main objectives are explored: firstly, establishing a link between the cardiac near-field RF sensing signal and cardiac physiology through comparisons with high-fidelity ground truth sensors; and secondly, utilizing this physiological understanding to explore new cardiac applications for near-field RF sensors. We determined that the near-field RF sensing signal, through specialized processing and analysis, exhibits a non-linear correlation with ventricular volume. This interpretation paves the way for advanced volumetric and vascular monitoring application to advance the capabilities of cardiac near-field RF sensing.","abstract_html":"Cardiovascular disease remains the leading cause of mortality worldwide, yet effective detection, monitoring, and timely intervention can significantly improve treatment outcomes. Early identification of conditions such as arrhythmias, valvular disorders, heart failure, and hypertension is crucial for enhancing patient outcomes. However, traditional detection and diagnosis methods are often confined to in-clinic examinations, which not only incur high costs, making them inaccessible for many, but also provide only episodic insights, potentially missing symptomatic periods. A paradigm shift to continuous cardiovascular monitoring could transform healthcare delivery by offering a continuous, accessible, and convenient analysis of cardiovascular health. Near-field radiofrequency (RF) sensing technology can enable this paradigm shift, by offering continuous, real-time heart and lung motion monitoring without direct skin contact, allowing for monitoring over clothing or via furniture integration. This non-contact capability sets it apart from conventional sensing methods like electrocardiography, ultrasound/echocardiography, or photoplethysmography. This thesis explores the physiological underpinnings that correlate cardiac motion with near-field RF sensing signals, the development of specialized algorithms for processing this distinctive data, and its clinical implications for convenient and continuous monitoring. The two main objectives are explored: firstly, establishing a link between the cardiac near-field RF sensing signal and cardiac physiology through comparisons with high-fidelity ground truth sensors; and secondly, utilizing this physiological understanding to explore new cardiac applications for near-field RF sensors. We determined that the near-field RF sensing signal, through specialized processing and analysis, exhibits a non-linear correlation with ventricular volume. This interpretation paves the way for advanced volumetric and vascular monitoring application to advance the capabilities of cardiac near-field RF sensing.","abstract_has_math":false,"creators":["Conroy, Thomas"],"institution":"Cornell University","degree_name":"Ph. D., Electrical and Computer Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kan, Edwin"],"committee_members":["Butcher, Jonathan","Sabuncu, Mert"],"year":2024,"date_issued":"2024-08","date_published":"2024-08","updated_at":"2026-11-19T03:11:32Z","subjects":["Cardiology","Non-invasive sensing","Radio-frequency systems"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/p868-6963"],"render_values":[{"text":"https://doi.org/10.7298/p868-6963","href":"https://doi.org/10.7298/p868-6963","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16611817"],"render_values":[{"text":"16611817","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 14449","ProQuest Publication ID: 31482951"],"render_values":[{"text":"ProQuest Submission ID: 14449","href":null,"code":true},{"text":"ProQuest Publication ID: 31482951","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/116422","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/116422","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":"embargoed","embargo_until":"2026-09-03","access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F116422","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Kan, Edwin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Butcher, Jonathan","Sabuncu, Mert"]},{"key":"dc:creator","label":"Author","values":["Conroy, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-14T19:59:05Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-09-03"]},{"key":"dc:date.issued","label":"Date","values":["2024-08"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/16611817"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Electrical and Computer Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cardiology","Non-invasive sensing","Radio-frequency systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16611817"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/p868-6963"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 14449","ProQuest Publication ID: 31482951"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/116422"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b1956bf3-4be1-4b7e-95b3-1990d96ca18e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Wearable Radio-Frequency Cardiac Sensing: Physiology, Algorithms, and Clinical Applications</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2024-08</PublicationDate> <DOI>https://doi.org/10.7298/p868-6963</DOI> <Authors> <Author> <DisplayName>Conroy, Thomas</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Keyword>Cardiology</Keyword> <Keyword>Non-invasive sensing</Keyword> <Keyword>Radio-frequency systems</Keyword> <Abstract>Cardiovascular disease remains the leading cause of mortality worldwide, yet effective detection, monitoring, and timely intervention can significantly improve treatment outcomes. Early identification of conditions such as arrhythmias, valvular disorders, heart failure, and hypertension is crucial for enhancing patient outcomes. However, traditional detection and diagnosis methods are often confined to in-clinic examinations, which not only incur high costs, making them inaccessible for many, but also provide only episodic insights, potentially missing symptomatic periods. A paradigm shift to continuous cardiovascular monitoring could transform healthcare delivery by offering a continuous, accessible, and convenient analysis of cardiovascular health. Near-field radiofrequency (RF) sensing technology can enable this paradigm shift, by offering continuous, real-time heart and lung motion monitoring without direct skin contact, allowing for monitoring over clothing or via furniture integration. This non-contact capability sets it apart from conventional sensing methods like electrocardiography, ultrasound/echocardiography, or photoplethysmography. This thesis explores the physiological underpinnings that correlate cardiac motion with near-field RF sensing signals, the development of specialized algorithms for processing this distinctive data, and its clinical implications for convenient and continuous monitoring. The two main objectives are explored: firstly, establishing a link between the cardiac near-field RF sensing signal and cardiac physiology through comparisons with high-fidelity ground truth sensors; and secondly, utilizing this physiological understanding to explore new cardiac applications for near-field RF sensors. We determined that the near-field RF sensing signal, through specialized processing and analysis, exhibits a non-linear correlation with ventricular volume. This interpretation paves the way for advanced volumetric and vascular monitoring application to advance the capabilities of cardiac near-field RF sensing.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Conroy, Thomas"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["143 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Cardiovascular disease remains the leading cause of mortality worldwide, yet effective detection, monitoring, and timely intervention can significantly improve treatment outcomes. Early identification of conditions such as arrhythmias, valvular disorders, heart failure, and hypertension is crucial for enhancing patient outcomes. However, traditional detection and diagnosis methods are often confined to in-clinic examinations, which not only incur high costs, making them inaccessible for many, but also provide only episodic insights, potentially missing symptomatic periods. A paradigm shift to continuous cardiovascular monitoring could transform healthcare delivery by offering a continuous, accessible, and convenient analysis of cardiovascular health. Near-field radiofrequency (RF) sensing technology can enable this paradigm shift, by offering continuous, real-time heart and lung motion monitoring without direct skin contact, allowing for monitoring over clothing or via furniture integration. This non-contact capability sets it apart from conventional sensing methods like electrocardiography, ultrasound/echocardiography, or photoplethysmography. This thesis explores the physiological underpinnings that correlate cardiac motion with near-field RF sensing signals, the development of specialized algorithms for processing this distinctive data, and its clinical implications for convenient and continuous monitoring. The two main objectives are explored: firstly, establishing a link between the cardiac near-field RF sensing signal and cardiac physiology through comparisons with high-fidelity ground truth sensors; and secondly, utilizing this physiological understanding to explore new cardiac applications for near-field RF sensors. We determined that the near-field RF sensing signal, through specialized processing and analysis, exhibits a non-linear correlation with ventricular volume. This interpretation paves the way for advanced volumetric and vascular monitoring application to advance the capabilities of cardiac near-field RF sensing."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Wearable Radio-Frequency Cardiac Sensing: Physiology, Algorithms, and Clinical Applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b1956bf3-4be1-4b7e-95b3-1990d96ca18e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Wearable Radio-Frequency Cardiac Sensing: Physiology, Algorithms, and Clinical Applications</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2024-08</PublicationDate> <DOI>https://doi.org/10.7298/p868-6963</DOI> <Authors> <Author> <DisplayName>Conroy, Thomas</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Keyword>Cardiology</Keyword> <Keyword>Non-invasive sensing</Keyword> <Keyword>Radio-frequency systems</Keyword> <Abstract>Cardiovascular disease remains the leading cause of mortality worldwide, yet effective detection, monitoring, and timely intervention can significantly improve treatment outcomes. Early identification of conditions such as arrhythmias, valvular disorders, heart failure, and hypertension is crucial for enhancing patient outcomes. However, traditional detection and diagnosis methods are often confined to in-clinic examinations, which not only incur high costs, making them inaccessible for many, but also provide only episodic insights, potentially missing symptomatic periods. A paradigm shift to continuous cardiovascular monitoring could transform healthcare delivery by offering a continuous, accessible, and convenient analysis of cardiovascular health. Near-field radiofrequency (RF) sensing technology can enable this paradigm shift, by offering continuous, real-time heart and lung motion monitoring without direct skin contact, allowing for monitoring over clothing or via furniture integration. This non-contact capability sets it apart from conventional sensing methods like electrocardiography, ultrasound/echocardiography, or photoplethysmography. This thesis explores the physiological underpinnings that correlate cardiac motion with near-field RF sensing signals, the development of specialized algorithms for processing this distinctive data, and its clinical implications for convenient and continuous monitoring. The two main objectives are explored: firstly, establishing a link between the cardiac near-field RF sensing signal and cardiac physiology through comparisons with high-fidelity ground truth sensors; and secondly, utilizing this physiological understanding to explore new cardiac applications for near-field RF sensors. We determined that the near-field RF sensing signal, through specialized processing and analysis, exhibits a non-linear correlation with ventricular volume. This interpretation paves the way for advanced volumetric and vascular monitoring application to advance the capabilities of cardiac near-field RF sensing.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Conroy, Thomas"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Kan, Edwin"],"dc:contributor.committeemember":["Butcher, Jonathan","Sabuncu, Mert"],"dc:creator":["Conroy, Thomas"],"dc:date.accessioned":["2025-01-14T19:59:05Z"],"dc:date.embargo":["2026-09-03"],"dc:date.issued":["2024-08"],"dc:description":["143 pages"],"dc:description.abstract":["Cardiovascular disease remains the leading cause of mortality worldwide, yet effective detection, monitoring, and timely intervention can significantly improve treatment outcomes. Early identification of conditions such as arrhythmias, valvular disorders, heart failure, and hypertension is crucial for enhancing patient outcomes. However, traditional detection and diagnosis methods are often confined to in-clinic examinations, which not only incur high costs, making them inaccessible for many, but also provide only episodic insights, potentially missing symptomatic periods. A paradigm shift to continuous cardiovascular monitoring could transform healthcare delivery by offering a continuous, accessible, and convenient analysis of cardiovascular health. Near-field radiofrequency (RF) sensing technology can enable this paradigm shift, by offering continuous, real-time heart and lung motion monitoring without direct skin contact, allowing for monitoring over clothing or via furniture integration. This non-contact capability sets it apart from conventional sensing methods like electrocardiography, ultrasound/echocardiography, or photoplethysmography. This thesis explores the physiological underpinnings that correlate cardiac motion with near-field RF sensing signals, the development of specialized algorithms for processing this distinctive data, and its clinical implications for convenient and continuous monitoring. The two main objectives are explored: firstly, establishing a link between the cardiac near-field RF sensing signal and cardiac physiology through comparisons with high-fidelity ground truth sensors; and secondly, utilizing this physiological understanding to explore new cardiac applications for near-field RF sensors. We determined that the near-field RF sensing signal, through specialized processing and analysis, exhibits a non-linear correlation with ventricular volume. This interpretation paves the way for advanced volumetric and vascular monitoring application to advance the capabilities of cardiac near-field RF sensing."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["16611817"],"dc:identifier.doi":["https://doi.org/10.7298/p868-6963"],"dc:identifier.other":["ProQuest Submission ID: 14449","ProQuest Publication ID: 31482951"],"dc:identifier.uri":["https://hdl.handle.net/1813/116422"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/16611817"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Cardiology","Non-invasive sensing","Radio-frequency systems"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Wearable Radio-Frequency Cardiac Sensing: Physiology, Algorithms, and Clinical Applications"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["embargo"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Electrical and Computer Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:11:32Z"}