{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/117513"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/117513","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Circuits for Wireless Sensing","abstract":"This dissertation presents circuits for wireless sensing, divided into two main parts. The first part focuses on receivers designed primarily for the mmwave range using sub-harmonic down-conversion to relax the phase noise and power consumption requirements of generating a local oscillator (LO) signal. An LTI analysis method for passive mixer-first receivers is introduced to simplify analyzing LC networks at the mixer input. A 4-phase sub-harmonic passive mixer-first receiver with improved reception at the third harmonic of the LO frequency is presented, using a class F$^{-1}$ LO buffer to shape the control the duty-cycle of the mixer switches’ conduction waveform and a shunt LC network at the front-end. Fabricated in INTEL 16 technology, the receiver demonstrates a noise figure of 9 dB, an out-of-band B1dB better than -18.63 dBm, and an out-of-band IIP3 better than 7.15 dBm, while consuming only 14.4 mW at around 60 GHz. The 4-phase design evolves into an 8-phase design, enabling reception at either the fundamental frequency or the third harmonic through output combination. An 8-phase design is also introduced for FMCW radar applications, incorporating an on-chip injection-locked class F$^{-1}$ oscillator. The second part addresses wireless micro-scale sensing systems for neural recording and pH measurement. The Micro-scale Optoelectronic Tetherless Electrode (MOTE) is the first wireless neural measurement system with a sub-nanoliter volume. It features on-chip integration of CMOS circuits and a microscale LED, allowing chronic in vivo neural activity recording in awake mice for over a year. The MOTE overcomes previous challenges in neural implants, including relative motion between the electrodes and the tissue and excessive volume displacement by implanted electronics. Building on the MOTE platform, a pH-measuring autonomous microsystem named the Redox-Enabled Microscale Opto-Electronically Transduced Electrode (ReMOTE) is introduced. The Re- MOTE contains two electrodes made of different materials, where the local pH influences the voltage between them. It is a tetherless, all-optical microsystem designed in a 180 nm CMOS SOI process, occupying just 417 $\\mu$m $\\times$ 48 $\\mu$m and consuming 2 $\\mu$W with a pH sensitivity of 42.53 mV/pH.","abstract_html":"This dissertation presents circuits for wireless sensing, divided into two main parts. The first part focuses on receivers designed primarily for the mmwave range using sub-harmonic down-conversion to relax the phase noise and power consumption requirements of generating a local oscillator (LO) signal. An LTI analysis method for passive mixer-first receivers is introduced to simplify analyzing LC networks at the mixer input. A 4-phase sub-harmonic passive mixer-first receiver with improved reception at the third harmonic of the LO frequency is presented, using a class F<span class=\"etd-inline-math\"><sup>-1</sup></span> LO buffer to shape the control the duty-cycle of the mixer switches’ conduction waveform and a shunt LC network at the front-end. Fabricated in INTEL 16 technology, the receiver demonstrates a noise figure of 9 dB, an out-of-band B1dB better than -18.63 dBm, and an out-of-band IIP3 better than 7.15 dBm, while consuming only 14.4 mW at around 60 GHz. The 4-phase design evolves into an 8-phase design, enabling reception at either the fundamental frequency or the third harmonic through output combination. An 8-phase design is also introduced for FMCW radar applications, incorporating an on-chip injection-locked class F<span class=\"etd-inline-math\"><sup>-1</sup></span> oscillator. The second part addresses wireless micro-scale sensing systems for neural recording and pH measurement. The Micro-scale Optoelectronic Tetherless Electrode (MOTE) is the first wireless neural measurement system with a sub-nanoliter volume. It features on-chip integration of CMOS circuits and a microscale LED, allowing chronic in vivo neural activity recording in awake mice for over a year. The MOTE overcomes previous challenges in neural implants, including relative motion between the electrodes and the tissue and excessive volume displacement by implanted electronics. Building on the MOTE platform, a pH-measuring autonomous microsystem named the Redox-Enabled Microscale Opto-Electronically Transduced Electrode (ReMOTE) is introduced. The Re- MOTE contains two electrodes made of different materials, where the local pH influences the voltage between them. It is a tetherless, all-optical microsystem designed in a 180 nm CMOS SOI process, occupying just 417 <span class=\"etd-inline-math\">&mu;</span>m $\\times$ 48 <span class=\"etd-inline-math\">&mu;</span>m and consuming 2 <span class=\"etd-inline-math\">&mu;</span>W with a pH sensitivity of 42.53 mV/pH.","abstract_has_math":true,"creators":["Ghajari, Shahab"],"institution":"Cornell University","degree_name":"Ph. D., Electrical and Computer Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Molnar, Alyosha"],"committee_members":["Apsel, Alyssa","Goldberg, Jesse","McEuen, Paul"],"year":2025,"date_issued":"2025-05","date_published":"2025-05","updated_at":"2026-11-19T03:12:03Z","subjects":["Automotive radar","Implant","MOTE","Passive mixers","pH","ReMOTE"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/dyr9-4060"],"render_values":[{"text":"https://doi.org/10.7298/dyr9-4060","href":"https://doi.org/10.7298/dyr9-4060","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16938481"],"render_values":[{"text":"16938481","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 14905","ProQuest Publication ID: 31997801"],"render_values":[{"text":"ProQuest Submission ID: 14905","href":null,"code":true},{"text":"ProQuest Publication ID: 31997801","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/117513","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/117513","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":"embargoed","embargo_until":"2026-06-18","access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F117513","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Molnar, Alyosha"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Apsel, Alyssa","Goldberg, Jesse","McEuen, Paul"]},{"key":"dc:creator","label":"Author","values":["Ghajari, Shahab"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-21T14:13:09Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-06-18"]},{"key":"dc:date.issued","label":"Date","values":["2025-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/16938481"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Electrical and Computer Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Automotive radar","Implant","MOTE","Passive mixers","pH","ReMOTE"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["16938481"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/dyr9-4060"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 14905","ProQuest Publication ID: 31997801"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/117513"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a809cef8-553c-4e31-9465-add356181877\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Circuits for Wireless Sensing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-05</PublicationDate> <DOI>https://doi.org/10.7298/dyr9-4060</DOI> <Authors> <Author> <DisplayName>Ghajari, Shahab</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Automotive radar</Keyword> <Keyword>Implant</Keyword> <Keyword>MOTE</Keyword> <Keyword>Passive mixers</Keyword> <Keyword>pH</Keyword> <Keyword>ReMOTE</Keyword> <Abstract>This dissertation presents circuits for wireless sensing, divided into two main parts. The first part focuses on receivers designed primarily for the mmwave range using sub-harmonic down-conversion to relax the phase noise and power consumption requirements of generating a local oscillator (LO) signal. An LTI analysis method for passive mixer-first receivers is introduced to simplify analyzing LC networks at the mixer input. A 4-phase sub-harmonic passive mixer-first receiver with improved reception at the third harmonic of the LO frequency is presented, using a class F$^{-1}$ LO buffer to shape the control the duty-cycle of the mixer switches’ conduction waveform and a shunt LC network at the front-end. Fabricated in INTEL 16 technology, the receiver demonstrates a noise figure of 9 dB, an out-of-band B1dB better than -18.63 dBm, and an out-of-band IIP3 better than 7.15 dBm, while consuming only 14.4 mW at around 60 GHz. The 4-phase design evolves into an 8-phase design, enabling reception at either the fundamental frequency or the third harmonic through output combination. An 8-phase design is also introduced for FMCW radar applications, incorporating an on-chip injection-locked class F$^{-1}$ oscillator. The second part addresses wireless micro-scale sensing systems for neural recording and pH measurement. The Micro-scale Optoelectronic Tetherless Electrode (MOTE) is the first wireless neural measurement system with a sub-nanoliter volume. It features on-chip integration of CMOS circuits and a microscale LED, allowing chronic in vivo neural activity recording in awake mice for over a year. The MOTE overcomes previous challenges in neural implants, including relative motion between the electrodes and the tissue and excessive volume displacement by implanted electronics. Building on the MOTE platform, a pH-measuring autonomous microsystem named the Redox-Enabled Microscale Opto-Electronically Transduced Electrode (ReMOTE) is introduced. The Re- MOTE contains two electrodes made of different materials, where the local pH influences the voltage between them. It is a tetherless, all-optical microsystem designed in a 180 nm CMOS SOI process, occupying just 417 $\\mu$m $\\times$ 48 $\\mu$m and consuming 2 $\\mu$W with a pH sensitivity of 42.53 mV/pH.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Ghajari, Shahab"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["146 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation presents circuits for wireless sensing, divided into two main parts. The first part focuses on receivers designed primarily for the mmwave range using sub-harmonic down-conversion to relax the phase noise and power consumption requirements of generating a local oscillator (LO) signal. An LTI analysis method for passive mixer-first receivers is introduced to simplify analyzing LC networks at the mixer input. A 4-phase sub-harmonic passive mixer-first receiver with improved reception at the third harmonic of the LO frequency is presented, using a class F$^{-1}$ LO buffer to shape the control the duty-cycle of the mixer switches’ conduction waveform and a shunt LC network at the front-end. Fabricated in INTEL 16 technology, the receiver demonstrates a noise figure of 9 dB, an out-of-band B1dB better than -18.63 dBm, and an out-of-band IIP3 better than 7.15 dBm, while consuming only 14.4 mW at around 60 GHz. The 4-phase design evolves into an 8-phase design, enabling reception at either the fundamental frequency or the third harmonic through output combination. An 8-phase design is also introduced for FMCW radar applications, incorporating an on-chip injection-locked class F$^{-1}$ oscillator. The second part addresses wireless micro-scale sensing systems for neural recording and pH measurement. The Micro-scale Optoelectronic Tetherless Electrode (MOTE) is the first wireless neural measurement system with a sub-nanoliter volume. It features on-chip integration of CMOS circuits and a microscale LED, allowing chronic in vivo neural activity recording in awake mice for over a year. The MOTE overcomes previous challenges in neural implants, including relative motion between the electrodes and the tissue and excessive volume displacement by implanted electronics. Building on the MOTE platform, a pH-measuring autonomous microsystem named the Redox-Enabled Microscale Opto-Electronically Transduced Electrode (ReMOTE) is introduced. The Re- MOTE contains two electrodes made of different materials, where the local pH influences the voltage between them. It is a tetherless, all-optical microsystem designed in a 180 nm CMOS SOI process, occupying just 417 $\\mu$m $\\times$ 48 $\\mu$m and consuming 2 $\\mu$W with a pH sensitivity of 42.53 mV/pH."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Circuits for Wireless Sensing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a809cef8-553c-4e31-9465-add356181877\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Circuits for Wireless Sensing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-05</PublicationDate> <DOI>https://doi.org/10.7298/dyr9-4060</DOI> <Authors> <Author> <DisplayName>Ghajari, Shahab</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Automotive radar</Keyword> <Keyword>Implant</Keyword> <Keyword>MOTE</Keyword> <Keyword>Passive mixers</Keyword> <Keyword>pH</Keyword> <Keyword>ReMOTE</Keyword> <Abstract>This dissertation presents circuits for wireless sensing, divided into two main parts. The first part focuses on receivers designed primarily for the mmwave range using sub-harmonic down-conversion to relax the phase noise and power consumption requirements of generating a local oscillator (LO) signal. An LTI analysis method for passive mixer-first receivers is introduced to simplify analyzing LC networks at the mixer input. A 4-phase sub-harmonic passive mixer-first receiver with improved reception at the third harmonic of the LO frequency is presented, using a class F$^{-1}$ LO buffer to shape the control the duty-cycle of the mixer switches’ conduction waveform and a shunt LC network at the front-end. Fabricated in INTEL 16 technology, the receiver demonstrates a noise figure of 9 dB, an out-of-band B1dB better than -18.63 dBm, and an out-of-band IIP3 better than 7.15 dBm, while consuming only 14.4 mW at around 60 GHz. The 4-phase design evolves into an 8-phase design, enabling reception at either the fundamental frequency or the third harmonic through output combination. An 8-phase design is also introduced for FMCW radar applications, incorporating an on-chip injection-locked class F$^{-1}$ oscillator. The second part addresses wireless micro-scale sensing systems for neural recording and pH measurement. The Micro-scale Optoelectronic Tetherless Electrode (MOTE) is the first wireless neural measurement system with a sub-nanoliter volume. It features on-chip integration of CMOS circuits and a microscale LED, allowing chronic in vivo neural activity recording in awake mice for over a year. The MOTE overcomes previous challenges in neural implants, including relative motion between the electrodes and the tissue and excessive volume displacement by implanted electronics. Building on the MOTE platform, a pH-measuring autonomous microsystem named the Redox-Enabled Microscale Opto-Electronically Transduced Electrode (ReMOTE) is introduced. The Re- MOTE contains two electrodes made of different materials, where the local pH influences the voltage between them. It is a tetherless, all-optical microsystem designed in a 180 nm CMOS SOI process, occupying just 417 $\\mu$m $\\times$ 48 $\\mu$m and consuming 2 $\\mu$W with a pH sensitivity of 42.53 mV/pH.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Ghajari, Shahab"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Molnar, Alyosha"],"dc:contributor.committeemember":["Apsel, Alyssa","Goldberg, Jesse","McEuen, Paul"],"dc:creator":["Ghajari, Shahab"],"dc:date.accessioned":["2025-08-21T14:13:09Z"],"dc:date.embargo":["2026-06-18"],"dc:date.issued":["2025-05"],"dc:description":["146 pages"],"dc:description.abstract":["This dissertation presents circuits for wireless sensing, divided into two main parts. The first part focuses on receivers designed primarily for the mmwave range using sub-harmonic down-conversion to relax the phase noise and power consumption requirements of generating a local oscillator (LO) signal. An LTI analysis method for passive mixer-first receivers is introduced to simplify analyzing LC networks at the mixer input. A 4-phase sub-harmonic passive mixer-first receiver with improved reception at the third harmonic of the LO frequency is presented, using a class F$^{-1}$ LO buffer to shape the control the duty-cycle of the mixer switches’ conduction waveform and a shunt LC network at the front-end. Fabricated in INTEL 16 technology, the receiver demonstrates a noise figure of 9 dB, an out-of-band B1dB better than -18.63 dBm, and an out-of-band IIP3 better than 7.15 dBm, while consuming only 14.4 mW at around 60 GHz. The 4-phase design evolves into an 8-phase design, enabling reception at either the fundamental frequency or the third harmonic through output combination. An 8-phase design is also introduced for FMCW radar applications, incorporating an on-chip injection-locked class F$^{-1}$ oscillator. The second part addresses wireless micro-scale sensing systems for neural recording and pH measurement. The Micro-scale Optoelectronic Tetherless Electrode (MOTE) is the first wireless neural measurement system with a sub-nanoliter volume. It features on-chip integration of CMOS circuits and a microscale LED, allowing chronic in vivo neural activity recording in awake mice for over a year. The MOTE overcomes previous challenges in neural implants, including relative motion between the electrodes and the tissue and excessive volume displacement by implanted electronics. Building on the MOTE platform, a pH-measuring autonomous microsystem named the Redox-Enabled Microscale Opto-Electronically Transduced Electrode (ReMOTE) is introduced. The Re- MOTE contains two electrodes made of different materials, where the local pH influences the voltage between them. It is a tetherless, all-optical microsystem designed in a 180 nm CMOS SOI process, occupying just 417 $\\mu$m $\\times$ 48 $\\mu$m and consuming 2 $\\mu$W with a pH sensitivity of 42.53 mV/pH."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["16938481"],"dc:identifier.doi":["https://doi.org/10.7298/dyr9-4060"],"dc:identifier.other":["ProQuest Submission ID: 14905","ProQuest Publication ID: 31997801"],"dc:identifier.uri":["https://hdl.handle.net/1813/117513"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/16938481"],"dc:subject":["Automotive radar","Implant","MOTE","Passive mixers","pH","ReMOTE"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Circuits for Wireless Sensing"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["embargo"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Electrical and Computer Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:12:03Z"}