{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/120651"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/120651","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"DESIGN, SYNTHESIS, AND CHARACTERIZATION OF A 3.2 nm PHOTO SWITCHABLE MOLECULAR RULER FOR ESR APPLICATIONS","abstract":"This thesis presents the design, synthesis, and characterization of a 32 Å photoswitchable molecular ruler for DEER (Double Electron-Electron Resonance) spectroscopy. Aimed at addressing the need for reliable and validated distance standards in pulsed dipolar ESR, the ruler features a rigid azobenzene-based spacer that undergoes light-induced cis-trans isomerization, enabling reversible switching from trans to cis conformation and thus giving a second distance. Its narrow distance distribution ensures high-precision measurements and reproducibility across different instruments and analysis methods. The study also establishes a protocol for the preparation of room temperature DEER samples by embedding the ruler in a polystyrene matrix. Overall, this work provides a versatile molecular standard to support more accurate and consistent DEER measurements in both structural biology and materials science.","abstract_html":"This thesis presents the design, synthesis, and characterization of a 32 Å photoswitchable molecular ruler for DEER (Double Electron-Electron Resonance) spectroscopy. Aimed at addressing the need for reliable and validated distance standards in pulsed dipolar ESR, the ruler features a rigid azobenzene-based spacer that undergoes light-induced cis-trans isomerization, enabling reversible switching from trans to cis conformation and thus giving a second distance. Its narrow distance distribution ensures high-precision measurements and reproducibility across different instruments and analysis methods. The study also establishes a protocol for the preparation of room temperature DEER samples by embedding the ruler in a polystyrene matrix. Overall, this work provides a versatile molecular standard to support more accurate and consistent DEER measurements in both structural biology and materials science.","abstract_has_math":false,"creators":["Joshi, Naman"],"institution":"Cornell University","degree_name":"M.S., Chemistry and Chemical Biology","degree_level":"Master of Science","degree_discipline":"Chemistry and Chemical Biology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Zax, David"],"committee_members":["Freed, Jack"],"year":2025,"date_issued":"2025-08","date_published":"2025-08","updated_at":"2026-11-19T03:12:35Z","subjects":["DEER","Electron Spin Resonance","Ruler"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/hjm7-jh80"],"render_values":[{"text":"https://doi.org/10.7298/hjm7-jh80","href":"https://doi.org/10.7298/hjm7-jh80","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17422379"],"render_values":[{"text":"17422379","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12559","ProQuest Publication ID: 32170766"],"render_values":[{"text":"ProQuest Submission ID: 12559","href":null,"code":true},{"text":"ProQuest Publication ID: 32170766","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/120651","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/120651","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F120651","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Zax, David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Freed, Jack"]},{"key":"dc:creator","label":"Author","values":["Joshi, Naman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-04-02T18:33:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-04-02T18:33:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry and Chemical Biology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Chemistry and Chemical Biology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["DEER","Electron Spin Resonance","Ruler"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17422379"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/hjm7-jh80"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12559","ProQuest Publication ID: 32170766"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/120651"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"ae350afa-6c29-4b9f-8838-9d93dd182f52\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>DESIGN, SYNTHESIS, AND CHARACTERIZATION OF A 3.2 nm PHOTO SWITCHABLE MOLECULAR RULER FOR ESR APPLICATIONS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-08</PublicationDate> <DOI>https://doi.org/10.7298/hjm7-jh80</DOI> <Authors> <Author> <DisplayName>Joshi, Naman</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>DEER</Keyword> <Keyword>Electron Spin Resonance</Keyword> <Keyword>Ruler</Keyword> <Abstract>This thesis presents the design, synthesis, and characterization of a 32 Å photoswitchable molecular ruler for DEER (Double Electron-Electron Resonance) spectroscopy. Aimed at addressing the need for reliable and validated distance standards in pulsed dipolar ESR, the ruler features a rigid azobenzene-based spacer that undergoes light-induced cis-trans isomerization, enabling reversible switching from trans to cis conformation and thus giving a second distance. Its narrow distance distribution ensures high-precision measurements and reproducibility across different instruments and analysis methods. The study also establishes a protocol for the preparation of room temperature DEER samples by embedding the ruler in a polystyrene matrix. Overall, this work provides a versatile molecular standard to support more accurate and consistent DEER measurements in both structural biology and materials science.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Joshi, Naman"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["64 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the design, synthesis, and characterization of a 32 Å photoswitchable molecular ruler for DEER (Double Electron-Electron Resonance) spectroscopy. Aimed at addressing the need for reliable and validated distance standards in pulsed dipolar ESR, the ruler features a rigid azobenzene-based spacer that undergoes light-induced cis-trans isomerization, enabling reversible switching from trans to cis conformation and thus giving a second distance. Its narrow distance distribution ensures high-precision measurements and reproducibility across different instruments and analysis methods. The study also establishes a protocol for the preparation of room temperature DEER samples by embedding the ruler in a polystyrene matrix. Overall, this work provides a versatile molecular standard to support more accurate and consistent DEER measurements in both structural biology and materials science."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["DESIGN, SYNTHESIS, AND CHARACTERIZATION OF A 3.2 nm PHOTO SWITCHABLE MOLECULAR RULER FOR ESR APPLICATIONS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"ae350afa-6c29-4b9f-8838-9d93dd182f52\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>DESIGN, SYNTHESIS, AND CHARACTERIZATION OF A 3.2 nm PHOTO SWITCHABLE MOLECULAR RULER FOR ESR APPLICATIONS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-08</PublicationDate> <DOI>https://doi.org/10.7298/hjm7-jh80</DOI> <Authors> <Author> <DisplayName>Joshi, Naman</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>DEER</Keyword> <Keyword>Electron Spin Resonance</Keyword> <Keyword>Ruler</Keyword> <Abstract>This thesis presents the design, synthesis, and characterization of a 32 Å photoswitchable molecular ruler for DEER (Double Electron-Electron Resonance) spectroscopy. Aimed at addressing the need for reliable and validated distance standards in pulsed dipolar ESR, the ruler features a rigid azobenzene-based spacer that undergoes light-induced cis-trans isomerization, enabling reversible switching from trans to cis conformation and thus giving a second distance. Its narrow distance distribution ensures high-precision measurements and reproducibility across different instruments and analysis methods. The study also establishes a protocol for the preparation of room temperature DEER samples by embedding the ruler in a polystyrene matrix. Overall, this work provides a versatile molecular standard to support more accurate and consistent DEER measurements in both structural biology and materials science.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Joshi, Naman"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Zax, David"],"dc:contributor.committeemember":["Freed, Jack"],"dc:creator":["Joshi, Naman"],"dc:date.accessioned":["2026-04-02T18:33:33Z"],"dc:date.available":["2026-04-02T18:33:33Z"],"dc:date.issued":["2025-08"],"dc:description":["64 pages"],"dc:description.abstract":["This thesis presents the design, synthesis, and characterization of a 32 Å photoswitchable molecular ruler for DEER (Double Electron-Electron Resonance) spectroscopy. Aimed at addressing the need for reliable and validated distance standards in pulsed dipolar ESR, the ruler features a rigid azobenzene-based spacer that undergoes light-induced cis-trans isomerization, enabling reversible switching from trans to cis conformation and thus giving a second distance. Its narrow distance distribution ensures high-precision measurements and reproducibility across different instruments and analysis methods. The study also establishes a protocol for the preparation of room temperature DEER samples by embedding the ruler in a polystyrene matrix. Overall, this work provides a versatile molecular standard to support more accurate and consistent DEER measurements in both structural biology and materials science."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["17422379"],"dc:identifier.doi":["https://doi.org/10.7298/hjm7-jh80"],"dc:identifier.other":["ProQuest Submission ID: 12559","ProQuest Publication ID: 32170766"],"dc:identifier.uri":["https://hdl.handle.net/1813/120651"],"dc:language.iso":["en"],"dc:subject":["DEER","Electron Spin Resonance","Ruler"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["DESIGN, SYNTHESIS, AND CHARACTERIZATION OF A 3.2 nm PHOTO SWITCHABLE MOLECULAR RULER FOR ESR APPLICATIONS"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry and Chemical Biology"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Chemistry and Chemical Biology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:12:35Z"}