{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/120678"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/120678","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"HIGH STRAIN RATE MEASUREMENTS FOR PREDICTING BRAIN TRAUMA","abstract":"Soft, high-speed sensors are crucial for real-time detection of mechanical de-formation in brain-like materials, particularly in studying mild traumatic brain injury (mTBI). This work presents the design, fabrication, and validation of stretchable optical fiber sensors using thermoplastic polyurethane waveguides paired with infrared optoelectronics. A repeatable process was established, pro- ducing sensors with consistent mechanical stiffness and electrical sensitivity un- der tensile loads. Dynamic testing was performed using ballistic and blunt im- pacts in hydrogel, silicone, and preserved sheep brain tissue. Results confirmed millisecond-scale responsiveness and sensitivity to both local deformation and impact propagation. Sensor performance under compressive and constrained conditions was also evaluated, revealing limitations due to pre-strain and ma- terial swelling. A localization framework based on LASSO regression was de- veloped and validated on a 2D sensor matrix. While complete 3D localization was not implemented, the system demonstrated feasibility for integration into future diagnostic platforms for mTBI detection and soft-tissue impact sensing.","abstract_html":"Soft, high-speed sensors are crucial for real-time detection of mechanical de-formation in brain-like materials, particularly in studying mild traumatic brain injury (mTBI). This work presents the design, fabrication, and validation of stretchable optical fiber sensors using thermoplastic polyurethane waveguides paired with infrared optoelectronics. A repeatable process was established, pro- ducing sensors with consistent mechanical stiffness and electrical sensitivity un- der tensile loads. Dynamic testing was performed using ballistic and blunt im- pacts in hydrogel, silicone, and preserved sheep brain tissue. Results confirmed millisecond-scale responsiveness and sensitivity to both local deformation and impact propagation. Sensor performance under compressive and constrained conditions was also evaluated, revealing limitations due to pre-strain and ma- terial swelling. A localization framework based on LASSO regression was de- veloped and validated on a 2D sensor matrix. While complete 3D localization was not implemented, the system demonstrated feasibility for integration into future diagnostic platforms for mTBI detection and soft-tissue impact sensing.","abstract_has_math":false,"creators":["Tovar, Mariana"],"institution":"Cornell University","degree_name":"M.S., Mechanical Engineering","degree_level":"Master of Science","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Shepherd, Robert"],"committee_members":["Nunez, Cara"],"year":2025,"date_issued":"2025-08","date_published":"2025-08","updated_at":"2026-11-19T03:12:35Z","subjects":[],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/wqdw-8b67"],"render_values":[{"text":"https://doi.org/10.7298/wqdw-8b67","href":"https://doi.org/10.7298/wqdw-8b67","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17422373"],"render_values":[{"text":"17422373","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12588","ProQuest Publication ID: 32171430"],"render_values":[{"text":"ProQuest Submission ID: 12588","href":null,"code":true},{"text":"ProQuest Publication ID: 32171430","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/120678","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/120678","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":"embargoed","embargo_until":"2026-03-09","access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F120678","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Shepherd, Robert"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Nunez, Cara"]},{"key":"dc:creator","label":"Author","values":["Tovar, Mariana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-04-02T18:34:03Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-03-09"]},{"key":"dc:date.issued","label":"Date","values":["2025-08"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17422373"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/wqdw-8b67"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12588","ProQuest Publication ID: 32171430"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/120678"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4008fa22-48ae-42b1-8ce7-ddb6cf76a5ce\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>HIGH STRAIN RATE MEASUREMENTS FOR PREDICTING BRAIN TRAUMA</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-08</PublicationDate> <DOI>https://doi.org/10.7298/wqdw-8b67</DOI> <Authors> <Author> <DisplayName>Tovar, Mariana</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Abstract>Soft, high-speed sensors are crucial for real-time detection of mechanical de-formation in brain-like materials, particularly in studying mild traumatic brain injury (mTBI). This work presents the design, fabrication, and validation of stretchable optical fiber sensors using thermoplastic polyurethane waveguides paired with infrared optoelectronics. A repeatable process was established, pro- ducing sensors with consistent mechanical stiffness and electrical sensitivity un- der tensile loads. Dynamic testing was performed using ballistic and blunt im- pacts in hydrogel, silicone, and preserved sheep brain tissue. Results confirmed millisecond-scale responsiveness and sensitivity to both local deformation and impact propagation. Sensor performance under compressive and constrained conditions was also evaluated, revealing limitations due to pre-strain and ma- terial swelling. A localization framework based on LASSO regression was de- veloped and validated on a 2D sensor matrix. While complete 3D localization was not implemented, the system demonstrated feasibility for integration into future diagnostic platforms for mTBI detection and soft-tissue impact sensing.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Tovar, Mariana"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["71 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Soft, high-speed sensors are crucial for real-time detection of mechanical de-formation in brain-like materials, particularly in studying mild traumatic brain injury (mTBI). This work presents the design, fabrication, and validation of stretchable optical fiber sensors using thermoplastic polyurethane waveguides paired with infrared optoelectronics. A repeatable process was established, pro- ducing sensors with consistent mechanical stiffness and electrical sensitivity un- der tensile loads. Dynamic testing was performed using ballistic and blunt im- pacts in hydrogel, silicone, and preserved sheep brain tissue. Results confirmed millisecond-scale responsiveness and sensitivity to both local deformation and impact propagation. Sensor performance under compressive and constrained conditions was also evaluated, revealing limitations due to pre-strain and ma- terial swelling. A localization framework based on LASSO regression was de- veloped and validated on a 2D sensor matrix. While complete 3D localization was not implemented, the system demonstrated feasibility for integration into future diagnostic platforms for mTBI detection and soft-tissue impact sensing."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["HIGH STRAIN RATE MEASUREMENTS FOR PREDICTING BRAIN TRAUMA"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4008fa22-48ae-42b1-8ce7-ddb6cf76a5ce\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>HIGH STRAIN RATE MEASUREMENTS FOR PREDICTING BRAIN TRAUMA</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-08</PublicationDate> <DOI>https://doi.org/10.7298/wqdw-8b67</DOI> <Authors> <Author> <DisplayName>Tovar, Mariana</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/4.0/</License> <Abstract>Soft, high-speed sensors are crucial for real-time detection of mechanical de-formation in brain-like materials, particularly in studying mild traumatic brain injury (mTBI). This work presents the design, fabrication, and validation of stretchable optical fiber sensors using thermoplastic polyurethane waveguides paired with infrared optoelectronics. A repeatable process was established, pro- ducing sensors with consistent mechanical stiffness and electrical sensitivity un- der tensile loads. Dynamic testing was performed using ballistic and blunt im- pacts in hydrogel, silicone, and preserved sheep brain tissue. Results confirmed millisecond-scale responsiveness and sensitivity to both local deformation and impact propagation. Sensor performance under compressive and constrained conditions was also evaluated, revealing limitations due to pre-strain and ma- terial swelling. A localization framework based on LASSO regression was de- veloped and validated on a 2D sensor matrix. While complete 3D localization was not implemented, the system demonstrated feasibility for integration into future diagnostic platforms for mTBI detection and soft-tissue impact sensing.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Tovar, Mariana"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Shepherd, Robert"],"dc:contributor.committeemember":["Nunez, Cara"],"dc:creator":["Tovar, Mariana"],"dc:date.accessioned":["2026-04-02T18:34:03Z"],"dc:date.embargo":["2026-03-09"],"dc:date.issued":["2025-08"],"dc:description":["71 pages"],"dc:description.abstract":["Soft, high-speed sensors are crucial for real-time detection of mechanical de-formation in brain-like materials, particularly in studying mild traumatic brain injury (mTBI). This work presents the design, fabrication, and validation of stretchable optical fiber sensors using thermoplastic polyurethane waveguides paired with infrared optoelectronics. A repeatable process was established, pro- ducing sensors with consistent mechanical stiffness and electrical sensitivity un- der tensile loads. Dynamic testing was performed using ballistic and blunt im- pacts in hydrogel, silicone, and preserved sheep brain tissue. Results confirmed millisecond-scale responsiveness and sensitivity to both local deformation and impact propagation. Sensor performance under compressive and constrained conditions was also evaluated, revealing limitations due to pre-strain and ma- terial swelling. A localization framework based on LASSO regression was de- veloped and validated on a 2D sensor matrix. While complete 3D localization was not implemented, the system demonstrated feasibility for integration into future diagnostic platforms for mTBI detection and soft-tissue impact sensing."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["17422373"],"dc:identifier.doi":["https://doi.org/10.7298/wqdw-8b67"],"dc:identifier.other":["ProQuest Submission ID: 12588","ProQuest Publication ID: 32171430"],"dc:identifier.uri":["https://hdl.handle.net/1813/120678"],"dc:language.iso":["en"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["https://creativecommons.org/licenses/by/4.0/"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["HIGH STRAIN RATE MEASUREMENTS FOR PREDICTING BRAIN TRAUMA"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:12:35Z"}