{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/120679"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/120679","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Improved Near Infrared Analysis Method for Bovine Milk","abstract":"This research strives to implement strong analytical chemistry technique to improve near infrared (NIR) predictive modeling of bovine milk. This is done with orthogonal sample set design as well as sturdy reference chemistry. A method for improving the accuracy of enzymatic assays for chemical reference testing methods for measurement of lactose and milk urea nitrogen (MUN) concentration in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized and unhomogenized milks were created for measurement of the concentration of fat, protein, lactose, and total solids using a commercial NIR instrument. The external validation performance of the NIR prediction models developed in our study exceeded all previously published NIR prediction models for fat, protein, lactose and total solids. These methods will aid in possible implementation of NIR milk analysis and for rapid in-line milk analysis.","abstract_html":"This research strives to implement strong analytical chemistry technique to improve near infrared (NIR) predictive modeling of bovine milk. This is done with orthogonal sample set design as well as sturdy reference chemistry. A method for improving the accuracy of enzymatic assays for chemical reference testing methods for measurement of lactose and milk urea nitrogen (MUN) concentration in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized and unhomogenized milks were created for measurement of the concentration of fat, protein, lactose, and total solids using a commercial NIR instrument. The external validation performance of the NIR prediction models developed in our study exceeded all previously published NIR prediction models for fat, protein, lactose and total solids. These methods will aid in possible implementation of NIR milk analysis and for rapid in-line milk analysis.","abstract_has_math":false,"creators":["Spillane, Allison"],"institution":"Cornell University","degree_name":"M.S., Food Science and Technology","degree_level":"Master of Science","degree_discipline":"Food Science and Technology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Barbano, David"],"committee_members":["Wolf, Christopher"],"year":2025,"date_issued":"2025-08","date_published":"2025-08","updated_at":"2026-11-19T03:12:35Z","subjects":["Analysis","Cuvette","Dairy","Infrared","Milk","Spectroscopy"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/m09b-t597"],"render_values":[{"text":"https://doi.org/10.7298/m09b-t597","href":"https://doi.org/10.7298/m09b-t597","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17422511"],"render_values":[{"text":"17422511","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12528","ProQuest Publication ID: 32169455"],"render_values":[{"text":"ProQuest Submission ID: 12528","href":null,"code":true},{"text":"ProQuest Publication ID: 32169455","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/120679","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/120679","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F120679","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Barbano, David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wolf, Christopher"]},{"key":"dc:creator","label":"Author","values":["Spillane, Allison"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-04-02T18:34:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-04-02T18:34:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Food Science and Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Food Science and Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analysis","Cuvette","Dairy","Infrared","Milk","Spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17422511"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/m09b-t597"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 12528","ProQuest Publication ID: 32169455"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/120679"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4d593bb5-5913-44aa-a4ec-14bf230ed858\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Improved Near Infrared Analysis Method for Bovine Milk</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-08</PublicationDate> <DOI>https://doi.org/10.7298/m09b-t597</DOI> <Authors> <Author> <DisplayName>Spillane, Allison</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Analysis</Keyword> <Keyword>Cuvette</Keyword> <Keyword>Dairy</Keyword> <Keyword>Infrared</Keyword> <Keyword>Milk</Keyword> <Keyword>Spectroscopy</Keyword> <Abstract>This research strives to implement strong analytical chemistry technique to improve near infrared (NIR) predictive modeling of bovine milk. This is done with orthogonal sample set design as well as sturdy reference chemistry. A method for improving the accuracy of enzymatic assays for chemical reference testing methods for measurement of lactose and milk urea nitrogen (MUN) concentration in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized and unhomogenized milks were created for measurement of the concentration of fat, protein, lactose, and total solids using a commercial NIR instrument. The external validation performance of the NIR prediction models developed in our study exceeded all previously published NIR prediction models for fat, protein, lactose and total solids. These methods will aid in possible implementation of NIR milk analysis and for rapid in-line milk analysis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Spillane, Allison"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["79 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["This research strives to implement strong analytical chemistry technique to improve near infrared (NIR) predictive modeling of bovine milk. This is done with orthogonal sample set design as well as sturdy reference chemistry. A method for improving the accuracy of enzymatic assays for chemical reference testing methods for measurement of lactose and milk urea nitrogen (MUN) concentration in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized and unhomogenized milks were created for measurement of the concentration of fat, protein, lactose, and total solids using a commercial NIR instrument. The external validation performance of the NIR prediction models developed in our study exceeded all previously published NIR prediction models for fat, protein, lactose and total solids. These methods will aid in possible implementation of NIR milk analysis and for rapid in-line milk analysis."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Improved Near Infrared Analysis Method for Bovine Milk"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4d593bb5-5913-44aa-a4ec-14bf230ed858\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Improved Near Infrared Analysis Method for Bovine Milk</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-08</PublicationDate> <DOI>https://doi.org/10.7298/m09b-t597</DOI> <Authors> <Author> <DisplayName>Spillane, Allison</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Analysis</Keyword> <Keyword>Cuvette</Keyword> <Keyword>Dairy</Keyword> <Keyword>Infrared</Keyword> <Keyword>Milk</Keyword> <Keyword>Spectroscopy</Keyword> <Abstract>This research strives to implement strong analytical chemistry technique to improve near infrared (NIR) predictive modeling of bovine milk. This is done with orthogonal sample set design as well as sturdy reference chemistry. A method for improving the accuracy of enzymatic assays for chemical reference testing methods for measurement of lactose and milk urea nitrogen (MUN) concentration in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized and unhomogenized milks were created for measurement of the concentration of fat, protein, lactose, and total solids using a commercial NIR instrument. The external validation performance of the NIR prediction models developed in our study exceeded all previously published NIR prediction models for fat, protein, lactose and total solids. These methods will aid in possible implementation of NIR milk analysis and for rapid in-line milk analysis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Spillane, Allison"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Barbano, David"],"dc:contributor.committeemember":["Wolf, Christopher"],"dc:creator":["Spillane, Allison"],"dc:date.accessioned":["2026-04-02T18:34:04Z"],"dc:date.available":["2026-04-02T18:34:04Z"],"dc:date.issued":["2025-08"],"dc:description":["79 pages"],"dc:description.abstract":["This research strives to implement strong analytical chemistry technique to improve near infrared (NIR) predictive modeling of bovine milk. This is done with orthogonal sample set design as well as sturdy reference chemistry. A method for improving the accuracy of enzymatic assays for chemical reference testing methods for measurement of lactose and milk urea nitrogen (MUN) concentration in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized and unhomogenized milks were created for measurement of the concentration of fat, protein, lactose, and total solids using a commercial NIR instrument. The external validation performance of the NIR prediction models developed in our study exceeded all previously published NIR prediction models for fat, protein, lactose and total solids. These methods will aid in possible implementation of NIR milk analysis and for rapid in-line milk analysis."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["17422511"],"dc:identifier.doi":["https://doi.org/10.7298/m09b-t597"],"dc:identifier.other":["ProQuest Submission ID: 12528","ProQuest Publication ID: 32169455"],"dc:identifier.uri":["https://hdl.handle.net/1813/120679"],"dc:language.iso":["en"],"dc:subject":["Analysis","Cuvette","Dairy","Infrared","Milk","Spectroscopy"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Improved Near Infrared Analysis Method for Bovine Milk"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Food Science and Technology"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Food Science and Technology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:12:35Z"}