{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/121016"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/121016","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping","abstract":"Advances in quantitative MRI increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. In this work, we present three complementary developments that address these challenges: deep-learning–based motion correction for mGRE imaging, free-breathing whole-liver quantitative mapping using implicit neural representations, and susceptibility-based fibrosis assessment validated against histology. We first propose a temporal fusion network (tUnet) for motion correction of multi-echo gradient-echo (mGRE) images and further refine it using autofocus-derived, subject-specific motion trajectories to create a fine-tuned version (tftUnet). Evaluated in the context of quantitative susceptibility mapping (QSM) for Parkinson’s disease (PD), the method significantly improves image quality. In simulated brain data (n = 15), tUnet boosted SSIM, PSNR, and RMSE (all p < 0.05). In nine PD patients with real motion artifacts, radiologist scoring increased from 1.11 ± 0.33 (uncorrected) to 2.56 ± 1.01 (tUnet) and 3.33 ± 1.22 (tftUnet), demonstrating substantial suppression of motion artifacts in clinical QSM. Motivated by the broader need for motion-robust quantitative imaging, we also developed a free-breathing 3D whole-liver multi-parametric mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs static images, motion fields, water–fat separation, and parametric maps. In ten healthy subjects, FINR produced sharp, motion-free images with minimal bias compared with conventional breath-held imaging, with training requiring ~3 hours per subject and inference under 1 minute. Finally, to enable non-invasive assessment of chronic liver disease, we investigated whether mGRE-derived susceptibility sources can quantify fibrosis in ex-vivo liver explants. After fat–water separation, mGRE data were processed to obtain R2QSM and R2’QSM (R2’ = R2 – R2), isolating diamagnetic (negative) susceptibility related to fibrosis. In 20 fixed liver sections with histology, negative susceptibility differentiated mild (F0–F1) from moderate–advanced fibrosis (F2–F3; p = 0.0025), distinguished F2–F3 from cirrhosis (F4; p = 0.021), and separated early (F0–F2) from advanced disease (F3–F4) with 90% sensitivity, 90% specificity, and an AUC of 0.88. It outperformed other MRI parameters and showed positive correlations with fibrosis stage (r = 0.60 for R2*QSM; r = 0.58 for R2’QSM).","abstract_html":"Advances in quantitative MRI increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. In this work, we present three complementary developments that address these challenges: deep-learning–based motion correction for mGRE imaging, free-breathing whole-liver quantitative mapping using implicit neural representations, and susceptibility-based fibrosis assessment validated against histology. We first propose a temporal fusion network (tUnet) for motion correction of multi-echo gradient-echo (mGRE) images and further refine it using autofocus-derived, subject-specific motion trajectories to create a fine-tuned version (tftUnet). Evaluated in the context of quantitative susceptibility mapping (QSM) for Parkinson’s disease (PD), the method significantly improves image quality. In simulated brain data (n = 15), tUnet boosted SSIM, PSNR, and RMSE (all p &lt; 0.05). In nine PD patients with real motion artifacts, radiologist scoring increased from 1.11 ± 0.33 (uncorrected) to 2.56 ± 1.01 (tUnet) and 3.33 ± 1.22 (tftUnet), demonstrating substantial suppression of motion artifacts in clinical QSM. Motivated by the broader need for motion-robust quantitative imaging, we also developed a free-breathing 3D whole-liver multi-parametric mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs static images, motion fields, water–fat separation, and parametric maps. In ten healthy subjects, FINR produced sharp, motion-free images with minimal bias compared with conventional breath-held imaging, with training requiring ~3 hours per subject and inference under 1 minute. Finally, to enable non-invasive assessment of chronic liver disease, we investigated whether mGRE-derived susceptibility sources can quantify fibrosis in ex-vivo liver explants. After fat–water separation, mGRE data were processed to obtain R2QSM and R2’QSM (R2’ = R2 – R2), isolating diamagnetic (negative) susceptibility related to fibrosis. In 20 fixed liver sections with histology, negative susceptibility differentiated mild (F0–F1) from moderate–advanced fibrosis (F2–F3; p = 0.0025), distinguished F2–F3 from cirrhosis (F4; p = 0.021), and separated early (F0–F2) from advanced disease (F3–F4) with 90% sensitivity, 90% specificity, and an AUC of 0.88. It outperformed other MRI parameters and showed positive correlations with fibrosis stage (r = 0.60 for R2*QSM; r = 0.58 for R2’QSM).","abstract_has_math":false,"creators":["Li, Chao"],"institution":"Cornell University","degree_name":"Ph. D., Applied Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Zipfel, Warren"],"committee_members":["Wang, Yi","Xu, Chunhui"],"year":2025,"date_issued":"2025-12","date_published":"2025-12","updated_at":"2026-11-19T03:13:28Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/yfgk-pd08"],"render_values":[{"text":"https://doi.org/10.7298/yfgk-pd08","href":"https://doi.org/10.7298/yfgk-pd08","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17423377"],"render_values":[{"text":"17423377","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 15370","ProQuest Publication ID: 32286965"],"render_values":[{"text":"ProQuest Submission ID: 15370","href":null,"code":true},{"text":"ProQuest Publication ID: 32286965","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/121016","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/121016","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F121016","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Zipfel, Warren"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Yi","Xu, Chunhui"]},{"key":"dc:creator","label":"Author","values":["Li, Chao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-04-03T18:52:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-04-03T18:52:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-12"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["17423377"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/yfgk-pd08"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 15370","ProQuest Publication ID: 32286965"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/121016"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"7d707486-e23f-4026-aa9e-28d7cb159a62\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-12</PublicationDate> <DOI>https://doi.org/10.7298/yfgk-pd08</DOI> <Authors> <Author> <DisplayName>Li, Chao</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Advances in quantitative MRI increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. In this work, we present three complementary developments that address these challenges: deep-learning–based motion correction for mGRE imaging, free-breathing whole-liver quantitative mapping using implicit neural representations, and susceptibility-based fibrosis assessment validated against histology. We first propose a temporal fusion network (tUnet) for motion correction of multi-echo gradient-echo (mGRE) images and further refine it using autofocus-derived, subject-specific motion trajectories to create a fine-tuned version (tftUnet). Evaluated in the context of quantitative susceptibility mapping (QSM) for Parkinson’s disease (PD), the method significantly improves image quality. In simulated brain data (n = 15), tUnet boosted SSIM, PSNR, and RMSE (all p < 0.05). In nine PD patients with real motion artifacts, radiologist scoring increased from 1.11 ± 0.33 (uncorrected) to 2.56 ± 1.01 (tUnet) and 3.33 ± 1.22 (tftUnet), demonstrating substantial suppression of motion artifacts in clinical QSM. Motivated by the broader need for motion-robust quantitative imaging, we also developed a free-breathing 3D whole-liver multi-parametric mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs static images, motion fields, water–fat separation, and parametric maps. In ten healthy subjects, FINR produced sharp, motion-free images with minimal bias compared with conventional breath-held imaging, with training requiring ~3 hours per subject and inference under 1 minute. Finally, to enable non-invasive assessment of chronic liver disease, we investigated whether mGRE-derived susceptibility sources can quantify fibrosis in ex-vivo liver explants. After fat–water separation, mGRE data were processed to obtain R2QSM and R2’QSM (R2’ = R2 – R2), isolating diamagnetic (negative) susceptibility related to fibrosis. In 20 fixed liver sections with histology, negative susceptibility differentiated mild (F0–F1) from moderate–advanced fibrosis (F2–F3; p = 0.0025), distinguished F2–F3 from cirrhosis (F4; p = 0.021), and separated early (F0–F2) from advanced disease (F3–F4) with 90% sensitivity, 90% specificity, and an AUC of 0.88. It outperformed other MRI parameters and showed positive correlations with fibrosis stage (r = 0.60 for R2*QSM; r = 0.58 for R2’QSM).</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Li, Chao"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["126 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Advances in quantitative MRI increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. In this work, we present three complementary developments that address these challenges: deep-learning–based motion correction for mGRE imaging, free-breathing whole-liver quantitative mapping using implicit neural representations, and susceptibility-based fibrosis assessment validated against histology. We first propose a temporal fusion network (tUnet) for motion correction of multi-echo gradient-echo (mGRE) images and further refine it using autofocus-derived, subject-specific motion trajectories to create a fine-tuned version (tftUnet). Evaluated in the context of quantitative susceptibility mapping (QSM) for Parkinson’s disease (PD), the method significantly improves image quality. In simulated brain data (n = 15), tUnet boosted SSIM, PSNR, and RMSE (all p < 0.05). In nine PD patients with real motion artifacts, radiologist scoring increased from 1.11 ± 0.33 (uncorrected) to 2.56 ± 1.01 (tUnet) and 3.33 ± 1.22 (tftUnet), demonstrating substantial suppression of motion artifacts in clinical QSM. Motivated by the broader need for motion-robust quantitative imaging, we also developed a free-breathing 3D whole-liver multi-parametric mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs static images, motion fields, water–fat separation, and parametric maps. In ten healthy subjects, FINR produced sharp, motion-free images with minimal bias compared with conventional breath-held imaging, with training requiring ~3 hours per subject and inference under 1 minute. Finally, to enable non-invasive assessment of chronic liver disease, we investigated whether mGRE-derived susceptibility sources can quantify fibrosis in ex-vivo liver explants. After fat–water separation, mGRE data were processed to obtain R2QSM and R2’QSM (R2’ = R2 – R2), isolating diamagnetic (negative) susceptibility related to fibrosis. In 20 fixed liver sections with histology, negative susceptibility differentiated mild (F0–F1) from moderate–advanced fibrosis (F2–F3; p = 0.0025), distinguished F2–F3 from cirrhosis (F4; p = 0.021), and separated early (F0–F2) from advanced disease (F3–F4) with 90% sensitivity, 90% specificity, and an AUC of 0.88. It outperformed other MRI parameters and showed positive correlations with fibrosis stage (r = 0.60 for R2*QSM; r = 0.58 for R2’QSM)."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"7d707486-e23f-4026-aa9e-28d7cb159a62\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-12</PublicationDate> <DOI>https://doi.org/10.7298/yfgk-pd08</DOI> <Authors> <Author> <DisplayName>Li, Chao</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Advances in quantitative MRI increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. In this work, we present three complementary developments that address these challenges: deep-learning–based motion correction for mGRE imaging, free-breathing whole-liver quantitative mapping using implicit neural representations, and susceptibility-based fibrosis assessment validated against histology. We first propose a temporal fusion network (tUnet) for motion correction of multi-echo gradient-echo (mGRE) images and further refine it using autofocus-derived, subject-specific motion trajectories to create a fine-tuned version (tftUnet). Evaluated in the context of quantitative susceptibility mapping (QSM) for Parkinson’s disease (PD), the method significantly improves image quality. In simulated brain data (n = 15), tUnet boosted SSIM, PSNR, and RMSE (all p < 0.05). In nine PD patients with real motion artifacts, radiologist scoring increased from 1.11 ± 0.33 (uncorrected) to 2.56 ± 1.01 (tUnet) and 3.33 ± 1.22 (tftUnet), demonstrating substantial suppression of motion artifacts in clinical QSM. Motivated by the broader need for motion-robust quantitative imaging, we also developed a free-breathing 3D whole-liver multi-parametric mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs static images, motion fields, water–fat separation, and parametric maps. In ten healthy subjects, FINR produced sharp, motion-free images with minimal bias compared with conventional breath-held imaging, with training requiring ~3 hours per subject and inference under 1 minute. Finally, to enable non-invasive assessment of chronic liver disease, we investigated whether mGRE-derived susceptibility sources can quantify fibrosis in ex-vivo liver explants. After fat–water separation, mGRE data were processed to obtain R2QSM and R2’QSM (R2’ = R2 – R2), isolating diamagnetic (negative) susceptibility related to fibrosis. In 20 fixed liver sections with histology, negative susceptibility differentiated mild (F0–F1) from moderate–advanced fibrosis (F2–F3; p = 0.0025), distinguished F2–F3 from cirrhosis (F4; p = 0.021), and separated early (F0–F2) from advanced disease (F3–F4) with 90% sensitivity, 90% specificity, and an AUC of 0.88. It outperformed other MRI parameters and showed positive correlations with fibrosis stage (r = 0.60 for R2*QSM; r = 0.58 for R2’QSM).</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Li, Chao"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Zipfel, Warren"],"dc:contributor.committeemember":["Wang, Yi","Xu, Chunhui"],"dc:creator":["Li, Chao"],"dc:date.accessioned":["2026-04-03T18:52:06Z"],"dc:date.available":["2026-04-03T18:52:06Z"],"dc:date.issued":["2025-12"],"dc:description":["126 pages"],"dc:description.abstract":["Advances in quantitative MRI increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. In this work, we present three complementary developments that address these challenges: deep-learning–based motion correction for mGRE imaging, free-breathing whole-liver quantitative mapping using implicit neural representations, and susceptibility-based fibrosis assessment validated against histology. We first propose a temporal fusion network (tUnet) for motion correction of multi-echo gradient-echo (mGRE) images and further refine it using autofocus-derived, subject-specific motion trajectories to create a fine-tuned version (tftUnet). Evaluated in the context of quantitative susceptibility mapping (QSM) for Parkinson’s disease (PD), the method significantly improves image quality. In simulated brain data (n = 15), tUnet boosted SSIM, PSNR, and RMSE (all p < 0.05). In nine PD patients with real motion artifacts, radiologist scoring increased from 1.11 ± 0.33 (uncorrected) to 2.56 ± 1.01 (tUnet) and 3.33 ± 1.22 (tftUnet), demonstrating substantial suppression of motion artifacts in clinical QSM. Motivated by the broader need for motion-robust quantitative imaging, we also developed a free-breathing 3D whole-liver multi-parametric mapping technique capable of estimating water T1, water T2, fat fraction (FF), and R2*. Using a multi-echo 3D stack-of-spirals acquisition with inversion-recovery and T2-preparation, we designed an implicit neural representation–based fingerprinting method (FINR) that jointly reconstructs static images, motion fields, water–fat separation, and parametric maps. In ten healthy subjects, FINR produced sharp, motion-free images with minimal bias compared with conventional breath-held imaging, with training requiring ~3 hours per subject and inference under 1 minute. Finally, to enable non-invasive assessment of chronic liver disease, we investigated whether mGRE-derived susceptibility sources can quantify fibrosis in ex-vivo liver explants. After fat–water separation, mGRE data were processed to obtain R2QSM and R2’QSM (R2’ = R2 – R2), isolating diamagnetic (negative) susceptibility related to fibrosis. In 20 fixed liver sections with histology, negative susceptibility differentiated mild (F0–F1) from moderate–advanced fibrosis (F2–F3; p = 0.0025), distinguished F2–F3 from cirrhosis (F4; p = 0.021), and separated early (F0–F2) from advanced disease (F3–F4) with 90% sensitivity, 90% specificity, and an AUC of 0.88. It outperformed other MRI parameters and showed positive correlations with fibrosis stage (r = 0.60 for R2*QSM; r = 0.58 for R2’QSM)."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["17423377"],"dc:identifier.doi":["https://doi.org/10.7298/yfgk-pd08"],"dc:identifier.other":["ProQuest Submission ID: 15370","ProQuest Publication ID: 32286965"],"dc:identifier.uri":["https://hdl.handle.net/1813/121016"],"dc:language.iso":["en"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Applied Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:13:28Z"}