{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/126235"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/126235","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"PUTTING A SPRING IN YOUR STEP: A PATIENT FOCUSED FOOTWEAR SIMULATION DRIVEN BY MOTION CAPTURE DATA","abstract":"Motion capture and musculoskeletal models are widely used to evaluate footwear, but they simplify foot–shoe contact and cannot resolve bone stress and tendon loading driven by shoe geometry. Finite element models can capture these mechanics, yet their high computational cost and reliance on musculoskeletal inputs limit their use in high-throughput footwear testing in addition to obscuring contact-induced tendon loading. This study develops a simplified foot finite element model for rapid simulation, representing soft tissue as a spring network and bones as rigid bodies connected by joints with patient specific stiffnesses. A ground reaction force and fixed ankle angle derived from motion capture are applied, enabling the model to predict tendon loads. The model reduces simulation time from ~8 hours to under 10 minutes. This framework enables efficient footwear evaluation with improved insight into design-driven loading, supporting strategies to reduce bone stress injuries, tendonitis, and enhance overall comfort.","abstract_html":"Motion capture and musculoskeletal models are widely used to evaluate footwear, but they simplify foot–shoe contact and cannot resolve bone stress and tendon loading driven by shoe geometry. Finite element models can capture these mechanics, yet their high computational cost and reliance on musculoskeletal inputs limit their use in high-throughput footwear testing in addition to obscuring contact-induced tendon loading. This study develops a simplified foot finite element model for rapid simulation, representing soft tissue as a spring network and bones as rigid bodies connected by joints with patient specific stiffnesses. A ground reaction force and fixed ankle angle derived from motion capture are applied, enabling the model to predict tendon loads. The model reduces simulation time from ~8 hours to under 10 minutes. This framework enables efficient footwear evaluation with improved insight into design-driven loading, supporting strategies to reduce bone stress injuries, tendonitis, and enhance overall comfort.","abstract_has_math":false,"creators":["Allen, Sam"],"institution":"Cornell University","degree_name":"M.S., Mechanical Engineering","degree_level":"Master of Science","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Andarawis-Puri, Nelly"],"committee_members":["Shepherd, Robert"],"year":2026,"date_issued":"2026-05","date_published":"2026-05","updated_at":"2026-11-19T03:13:28Z","subjects":["Computation","Finite Element Analysis","Foot Biomechanics","Footwear","Simulation","Spring Network Element"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/yzkg-kc77"],"render_values":[{"text":"https://doi.org/10.7298/yzkg-kc77","href":"https://doi.org/10.7298/yzkg-kc77","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Allen_cornell_0058O_12736","https://www.proquest.com/LegacyDocView/DISSNUM/32678177"],"render_values":[{"text":"Allen_cornell_0058O_12736","href":null,"code":true},{"text":"https://www.proquest.com/LegacyDocView/DISSNUM/32678177","href":"https://www.proquest.com/LegacyDocView/DISSNUM/32678177","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/126235","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/126235","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F126235","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Andarawis-Puri, Nelly"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Shepherd, Robert"]},{"key":"dc:creator","label":"Author","values":["Allen, Sam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-08-26T19:32:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-08-26T19:32:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-05"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computation","Finite Element Analysis","Foot Biomechanics","Footwear","Simulation","Spring Network Element"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/yzkg-kc77"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Allen_cornell_0058O_12736","https://www.proquest.com/LegacyDocView/DISSNUM/32678177"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/126235"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"f6d63d39-7e45-45e0-87fd-2d02b5cf98f7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>PUTTING A SPRING IN YOUR STEP: A PATIENT FOCUSED FOOTWEAR SIMULATION DRIVEN BY MOTION CAPTURE DATA</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2026-05</PublicationDate> <DOI>https://doi.org/10.7298/yzkg-kc77</DOI> <Authors> <Author> <DisplayName>Allen, Sam</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Computation</Keyword> <Keyword>Finite Element Analysis</Keyword> <Keyword>Foot Biomechanics</Keyword> <Keyword>Footwear</Keyword> <Keyword>Simulation</Keyword> <Keyword>Spring Network Element</Keyword> <Abstract>Motion capture and musculoskeletal models are widely used to evaluate footwear, but they simplify foot–shoe contact and cannot resolve bone stress and tendon loading driven by shoe geometry. Finite element models can capture these mechanics, yet their high computational cost and reliance on musculoskeletal inputs limit their use in high-throughput footwear testing in addition to obscuring contact-induced tendon loading. This study develops a simplified foot finite element model for rapid simulation, representing soft tissue as a spring network and bones as rigid bodies connected by joints with patient specific stiffnesses. A ground reaction force and fixed ankle angle derived from motion capture are applied, enabling the model to predict tendon loads. The model reduces simulation time from ~8 hours to under 10 minutes. This framework enables efficient footwear evaluation with improved insight into design-driven loading, supporting strategies to reduce bone stress injuries, tendonitis, and enhance overall comfort.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Allen, Sam"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["83 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["Motion capture and musculoskeletal models are widely used to evaluate footwear, but they simplify foot–shoe contact and cannot resolve bone stress and tendon loading driven by shoe geometry. Finite element models can capture these mechanics, yet their high computational cost and reliance on musculoskeletal inputs limit their use in high-throughput footwear testing in addition to obscuring contact-induced tendon loading. This study develops a simplified foot finite element model for rapid simulation, representing soft tissue as a spring network and bones as rigid bodies connected by joints with patient specific stiffnesses. A ground reaction force and fixed ankle angle derived from motion capture are applied, enabling the model to predict tendon loads. The model reduces simulation time from ~8 hours to under 10 minutes. This framework enables efficient footwear evaluation with improved insight into design-driven loading, supporting strategies to reduce bone stress injuries, tendonitis, and enhance overall comfort."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810.2"]},{"key":"dc:title","label":"Title","values":["PUTTING A SPRING IN YOUR STEP: A PATIENT FOCUSED FOOTWEAR SIMULATION DRIVEN BY MOTION CAPTURE DATA"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"f6d63d39-7e45-45e0-87fd-2d02b5cf98f7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>PUTTING A SPRING IN YOUR STEP: A PATIENT FOCUSED FOOTWEAR SIMULATION DRIVEN BY MOTION CAPTURE DATA</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2026-05</PublicationDate> <DOI>https://doi.org/10.7298/yzkg-kc77</DOI> <Authors> <Author> <DisplayName>Allen, Sam</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Computation</Keyword> <Keyword>Finite Element Analysis</Keyword> <Keyword>Foot Biomechanics</Keyword> <Keyword>Footwear</Keyword> <Keyword>Simulation</Keyword> <Keyword>Spring Network Element</Keyword> <Abstract>Motion capture and musculoskeletal models are widely used to evaluate footwear, but they simplify foot–shoe contact and cannot resolve bone stress and tendon loading driven by shoe geometry. Finite element models can capture these mechanics, yet their high computational cost and reliance on musculoskeletal inputs limit their use in high-throughput footwear testing in addition to obscuring contact-induced tendon loading. This study develops a simplified foot finite element model for rapid simulation, representing soft tissue as a spring network and bones as rigid bodies connected by joints with patient specific stiffnesses. A ground reaction force and fixed ankle angle derived from motion capture are applied, enabling the model to predict tendon loads. The model reduces simulation time from ~8 hours to under 10 minutes. This framework enables efficient footwear evaluation with improved insight into design-driven loading, supporting strategies to reduce bone stress injuries, tendonitis, and enhance overall comfort.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Allen, Sam"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Andarawis-Puri, Nelly"],"dc:contributor.committeemember":["Shepherd, Robert"],"dc:creator":["Allen, Sam"],"dc:date.accessioned":["2026-08-26T19:32:12Z"],"dc:date.available":["2026-08-26T19:32:12Z"],"dc:date.issued":["2026-05"],"dc:description":["83 pages"],"dc:description.abstract":["Motion capture and musculoskeletal models are widely used to evaluate footwear, but they simplify foot–shoe contact and cannot resolve bone stress and tendon loading driven by shoe geometry. Finite element models can capture these mechanics, yet their high computational cost and reliance on musculoskeletal inputs limit their use in high-throughput footwear testing in addition to obscuring contact-induced tendon loading. This study develops a simplified foot finite element model for rapid simulation, representing soft tissue as a spring network and bones as rigid bodies connected by joints with patient specific stiffnesses. A ground reaction force and fixed ankle angle derived from motion capture are applied, enabling the model to predict tendon loads. The model reduces simulation time from ~8 hours to under 10 minutes. This framework enables efficient footwear evaluation with improved insight into design-driven loading, supporting strategies to reduce bone stress injuries, tendonitis, and enhance overall comfort."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.doi":["https://doi.org/10.7298/yzkg-kc77"],"dc:identifier.other":["Allen_cornell_0058O_12736","https://www.proquest.com/LegacyDocView/DISSNUM/32678177"],"dc:identifier.uri":["https://hdl.handle.net/1813/126235"],"dc:language.iso":["en"],"dc:subject":["Computation","Finite Element Analysis","Foot Biomechanics","Footwear","Simulation","Spring Network Element"],"dcterms:license":["https://hdl.handle.net/1813/59810.2"],"dc:title":["PUTTING A SPRING IN YOUR STEP: A PATIENT FOCUSED FOOTWEAR SIMULATION DRIVEN BY MOTION CAPTURE DATA"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:13:28Z"}