{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/14033"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/14033","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents","abstract":"Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies.","abstract_html":"Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies.","abstract_has_math":false,"creators":["Sung, Jong"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-10-14T20:04:39Z","date_published":"2009-10-14T20:04:39Z","updated_at":"2026-11-19T03:14:09Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["6714432"],"render_values":[{"text":"6714432","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/14033","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/14033","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F14033","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Sung, Jong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-10-14T20:04:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-10-14T06:24:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-10-14T20:04:39Z"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["6714432"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/14033"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b84c6648-16af-45b4-a686-75c72c779b8f\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009-10-14T20:04:39Z</PublicationDate> <Authors> <Author> <DisplayName>Sung, Jong</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Sung, Jong"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b84c6648-16af-45b4-a686-75c72c779b8f\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009-10-14T20:04:39Z</PublicationDate> <Authors> <Author> <DisplayName>Sung, Jong</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Sung, Jong"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:creator":["Sung, Jong"],"dc:date.accessioned":["2009-10-14T20:04:39Z"],"dc:date.available":["2014-10-14T06:24:05Z"],"dc:date.issued":["2009-10-14T20:04:39Z"],"dc:description.abstract":["Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["6714432"],"dc:identifier.uri":["https://hdl.handle.net/1813/14033"],"dc:language.iso":["en_US"],"dc:title":["Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T03:14:09Z"}