{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/14824"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/14824","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Batch Fabrication Of Cantilevered Magnetic Nanorods On Attonewton-Sensitivity Silicon Oscillators For Magnetic Resonance Force Microscopy","abstract":"Magnetic resonance spectroscopy and imaging are powerful tools for characterizing soft materials at length scales down to a few microns. While mechanical detection has enabled observation of magnetic resonance from single electron spins and nanoscale volumes of nuclear spins, all such experiments to date have required manually afﬁxing a magnetic particle or a sample to the leading edge of a fragile microcantilever. In this dissertation, work to batch-fabricate attonewton sensitivity cantilevers with integrated, overhanging nickel magnets is described. That the magnet overhangs the leading edge of the cantilever is necessary to mitigate surface-induced force noise, the dominant source of noise in all high-sensitivity magnetic resonance force microscopy measurements to date. The smallest magnets produced had diameters of 70 nm. Three methods were developed to produce such overhanging magnets on single-crystal silicon cantilevers. Proof-of-concept work was demonstrated on methods involving under-etching the magnetic nanorods using potassium hydroxide, and fabricating the nanorods over co-planar silicon oxide pillars. Complete devices were produced via a method in which the magnetic nanorods were under-etched by an isotropic sulfur hexaﬂuoride reactive ion plasma etch. In addition to developing processes to produce overhanging nanorods, signiﬁcant challenges in lithographic alignment and silicide formation were over- come. Cantilever magnetometry demonstrated a net tip magnetization between 57 and 77 % of that expected for bulk nickel. Good leading-edge magnetization of the nanorods was conﬁrmed by using the cantilevers to detect, via forcegradients, electron spin resonance from nitroxide spin labels in a thin ﬁlm. This is the ﬁrst time that magnetic resonance force microscopy has been implemented with magnet-tipped cantilevers produced by batch fabrication. Over the same thin ﬁlm used for the electron spin resonance experiment, the cantilevers were shown to have extremely low surface-induced force noise. The work covered in this dissertation signiﬁcantly advances the feasibility of scanned-probe nanoscale magnetic resonance imaging of as-fabricated thin-ﬁlm samples and devices.","abstract_html":"Magnetic resonance spectroscopy and imaging are powerful tools for characterizing soft materials at length scales down to a few microns. While mechanical detection has enabled observation of magnetic resonance from single electron spins and nanoscale volumes of nuclear spins, all such experiments to date have required manually afﬁxing a magnetic particle or a sample to the leading edge of a fragile microcantilever. In this dissertation, work to batch-fabricate attonewton sensitivity cantilevers with integrated, overhanging nickel magnets is described. That the magnet overhangs the leading edge of the cantilever is necessary to mitigate surface-induced force noise, the dominant source of noise in all high-sensitivity magnetic resonance force microscopy measurements to date. The smallest magnets produced had diameters of 70 nm. Three methods were developed to produce such overhanging magnets on single-crystal silicon cantilevers. Proof-of-concept work was demonstrated on methods involving under-etching the magnetic nanorods using potassium hydroxide, and fabricating the nanorods over co-planar silicon oxide pillars. Complete devices were produced via a method in which the magnetic nanorods were under-etched by an isotropic sulfur hexaﬂuoride reactive ion plasma etch. In addition to developing processes to produce overhanging nanorods, signiﬁcant challenges in lithographic alignment and silicide formation were over- come. Cantilever magnetometry demonstrated a net tip magnetization between 57 and 77 % of that expected for bulk nickel. Good leading-edge magnetization of the nanorods was conﬁrmed by using the cantilevers to detect, via forcegradients, electron spin resonance from nitroxide spin labels in a thin ﬁlm. This is the ﬁrst time that magnetic resonance force microscopy has been implemented with magnet-tipped cantilevers produced by batch fabrication. Over the same thin ﬁlm used for the electron spin resonance experiment, the cantilevers were shown to have extremely low surface-induced force noise. The work covered in this dissertation signiﬁcantly advances the feasibility of scanned-probe nanoscale magnetic resonance imaging of as-fabricated thin-ﬁlm samples and devices.","abstract_has_math":false,"creators":["Hickman, Steven"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-04-09T20:24:20Z","date_published":"2010-04-09T20:24:20Z","updated_at":"2026-11-19T03:14:35Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["6890958"],"render_values":[{"text":"6890958","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/14824","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/14824","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F14824","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hickman, Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-04-09T20:24:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-04-09T06:27:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-04-09T20:24:20Z"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["6890958"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/14824"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c0b99c4a-d833-4159-a082-56aef1e1549e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Batch Fabrication Of Cantilevered Magnetic Nanorods On Attonewton-Sensitivity Silicon Oscillators For Magnetic Resonance Force Microscopy</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2010-04-09T20:24:20Z</PublicationDate> <Authors> <Author> <DisplayName>Hickman, Steven</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Magnetic resonance spectroscopy and imaging are powerful tools for characterizing soft materials at length scales down to a few microns. While mechanical detection has enabled observation of magnetic resonance from single electron spins and nanoscale volumes of nuclear spins, all such experiments to date have required manually afﬁxing a magnetic particle or a sample to the leading edge of a fragile microcantilever. In this dissertation, work to batch-fabricate attonewton sensitivity cantilevers with integrated, overhanging nickel magnets is described. That the magnet overhangs the leading edge of the cantilever is necessary to mitigate surface-induced force noise, the dominant source of noise in all high-sensitivity magnetic resonance force microscopy measurements to date. The smallest magnets produced had diameters of 70 nm. Three methods were developed to produce such overhanging magnets on single-crystal silicon cantilevers. Proof-of-concept work was demonstrated on methods involving under-etching the magnetic nanorods using potassium hydroxide, and fabricating the nanorods over co-planar silicon oxide pillars. Complete devices were produced via a method in which the magnetic nanorods were under-etched by an isotropic sulfur hexaﬂuoride reactive ion plasma etch. In addition to developing processes to produce overhanging nanorods, signiﬁcant challenges in lithographic alignment and silicide formation were over- come. Cantilever magnetometry demonstrated a net tip magnetization between 57 and 77 % of that expected for bulk nickel. Good leading-edge magnetization of the nanorods was conﬁrmed by using the cantilevers to detect, via forcegradients, electron spin resonance from nitroxide spin labels in a thin ﬁlm. This is the ﬁrst time that magnetic resonance force microscopy has been implemented with magnet-tipped cantilevers produced by batch fabrication. Over the same thin ﬁlm used for the electron spin resonance experiment, the cantilevers were shown to have extremely low surface-induced force noise. The work covered in this dissertation signiﬁcantly advances the feasibility of scanned-probe nanoscale magnetic resonance imaging of as-fabricated thin-ﬁlm samples and devices.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Hickman, Steven"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance spectroscopy and imaging are powerful tools for characterizing soft materials at length scales down to a few microns. While mechanical detection has enabled observation of magnetic resonance from single electron spins and nanoscale volumes of nuclear spins, all such experiments to date have required manually afﬁxing a magnetic particle or a sample to the leading edge of a fragile microcantilever. In this dissertation, work to batch-fabricate attonewton sensitivity cantilevers with integrated, overhanging nickel magnets is described. That the magnet overhangs the leading edge of the cantilever is necessary to mitigate surface-induced force noise, the dominant source of noise in all high-sensitivity magnetic resonance force microscopy measurements to date. The smallest magnets produced had diameters of 70 nm. Three methods were developed to produce such overhanging magnets on single-crystal silicon cantilevers. Proof-of-concept work was demonstrated on methods involving under-etching the magnetic nanorods using potassium hydroxide, and fabricating the nanorods over co-planar silicon oxide pillars. Complete devices were produced via a method in which the magnetic nanorods were under-etched by an isotropic sulfur hexaﬂuoride reactive ion plasma etch. In addition to developing processes to produce overhanging nanorods, signiﬁcant challenges in lithographic alignment and silicide formation were over- come. Cantilever magnetometry demonstrated a net tip magnetization between 57 and 77 % of that expected for bulk nickel. Good leading-edge magnetization of the nanorods was conﬁrmed by using the cantilevers to detect, via forcegradients, electron spin resonance from nitroxide spin labels in a thin ﬁlm. This is the ﬁrst time that magnetic resonance force microscopy has been implemented with magnet-tipped cantilevers produced by batch fabrication. Over the same thin ﬁlm used for the electron spin resonance experiment, the cantilevers were shown to have extremely low surface-induced force noise. The work covered in this dissertation signiﬁcantly advances the feasibility of scanned-probe nanoscale magnetic resonance imaging of as-fabricated thin-ﬁlm samples and devices."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Batch Fabrication Of Cantilevered Magnetic Nanorods On Attonewton-Sensitivity Silicon Oscillators For Magnetic Resonance Force Microscopy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"c0b99c4a-d833-4159-a082-56aef1e1549e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Batch Fabrication Of Cantilevered Magnetic Nanorods On Attonewton-Sensitivity Silicon Oscillators For Magnetic Resonance Force Microscopy</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2010-04-09T20:24:20Z</PublicationDate> <Authors> <Author> <DisplayName>Hickman, Steven</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Abstract>Magnetic resonance spectroscopy and imaging are powerful tools for characterizing soft materials at length scales down to a few microns. While mechanical detection has enabled observation of magnetic resonance from single electron spins and nanoscale volumes of nuclear spins, all such experiments to date have required manually afﬁxing a magnetic particle or a sample to the leading edge of a fragile microcantilever. In this dissertation, work to batch-fabricate attonewton sensitivity cantilevers with integrated, overhanging nickel magnets is described. That the magnet overhangs the leading edge of the cantilever is necessary to mitigate surface-induced force noise, the dominant source of noise in all high-sensitivity magnetic resonance force microscopy measurements to date. The smallest magnets produced had diameters of 70 nm. Three methods were developed to produce such overhanging magnets on single-crystal silicon cantilevers. Proof-of-concept work was demonstrated on methods involving under-etching the magnetic nanorods using potassium hydroxide, and fabricating the nanorods over co-planar silicon oxide pillars. Complete devices were produced via a method in which the magnetic nanorods were under-etched by an isotropic sulfur hexaﬂuoride reactive ion plasma etch. In addition to developing processes to produce overhanging nanorods, signiﬁcant challenges in lithographic alignment and silicide formation were over- come. Cantilever magnetometry demonstrated a net tip magnetization between 57 and 77 % of that expected for bulk nickel. Good leading-edge magnetization of the nanorods was conﬁrmed by using the cantilevers to detect, via forcegradients, electron spin resonance from nitroxide spin labels in a thin ﬁlm. This is the ﬁrst time that magnetic resonance force microscopy has been implemented with magnet-tipped cantilevers produced by batch fabrication. Over the same thin ﬁlm used for the electron spin resonance experiment, the cantilevers were shown to have extremely low surface-induced force noise. The work covered in this dissertation signiﬁcantly advances the feasibility of scanned-probe nanoscale magnetic resonance imaging of as-fabricated thin-ﬁlm samples and devices.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Hickman, Steven"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:creator":["Hickman, Steven"],"dc:date.accessioned":["2010-04-09T20:24:20Z"],"dc:date.available":["2015-04-09T06:27:41Z"],"dc:date.issued":["2010-04-09T20:24:20Z"],"dc:description.abstract":["Magnetic resonance spectroscopy and imaging are powerful tools for characterizing soft materials at length scales down to a few microns. While mechanical detection has enabled observation of magnetic resonance from single electron spins and nanoscale volumes of nuclear spins, all such experiments to date have required manually afﬁxing a magnetic particle or a sample to the leading edge of a fragile microcantilever. In this dissertation, work to batch-fabricate attonewton sensitivity cantilevers with integrated, overhanging nickel magnets is described. That the magnet overhangs the leading edge of the cantilever is necessary to mitigate surface-induced force noise, the dominant source of noise in all high-sensitivity magnetic resonance force microscopy measurements to date. The smallest magnets produced had diameters of 70 nm. Three methods were developed to produce such overhanging magnets on single-crystal silicon cantilevers. Proof-of-concept work was demonstrated on methods involving under-etching the magnetic nanorods using potassium hydroxide, and fabricating the nanorods over co-planar silicon oxide pillars. Complete devices were produced via a method in which the magnetic nanorods were under-etched by an isotropic sulfur hexaﬂuoride reactive ion plasma etch. In addition to developing processes to produce overhanging nanorods, signiﬁcant challenges in lithographic alignment and silicide formation were over- come. Cantilever magnetometry demonstrated a net tip magnetization between 57 and 77 % of that expected for bulk nickel. Good leading-edge magnetization of the nanorods was conﬁrmed by using the cantilevers to detect, via forcegradients, electron spin resonance from nitroxide spin labels in a thin ﬁlm. This is the ﬁrst time that magnetic resonance force microscopy has been implemented with magnet-tipped cantilevers produced by batch fabrication. Over the same thin ﬁlm used for the electron spin resonance experiment, the cantilevers were shown to have extremely low surface-induced force noise. The work covered in this dissertation signiﬁcantly advances the feasibility of scanned-probe nanoscale magnetic resonance imaging of as-fabricated thin-ﬁlm samples and devices."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["6890958"],"dc:identifier.uri":["https://hdl.handle.net/1813/14824"],"dc:language.iso":["en_US"],"dc:title":["Batch Fabrication Of Cantilevered Magnetic Nanorods On Attonewton-Sensitivity Silicon Oscillators For Magnetic Resonance Force Microscopy"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T03:14:35Z"}