{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/29334"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/29334","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Microfabrication Of Hydrogel Substrates Of Tunable Young'S Modulus","abstract":"Much is known about the effects of matrix stiffness and matrix topography on cell behavior, however they are seldom investigated in tandem. Presented and validated here is a micromolding method to introduce topographical features onto polyacrylamide (PA) substrates of tunable Young's modulus (E ). Feature fidelity is largely influenced by hydrogel swelling and most efficient on gels with a crosslinker concentration above 4.5%. However, this swelling does not affect the spacing of surface patterned ligands on two-dimensional PA gels. Bovine aortic endothelial cells (BAECs) cultured on linear micromolded features exhibit greater degrees of contact guidance with greater substrate E . Also described are applications of micromolding for future studies in cell mechanics.","abstract_html":"Much is known about the effects of matrix stiffness and matrix topography on cell behavior, however they are seldom investigated in tandem. Presented and validated here is a micromolding method to introduce topographical features onto polyacrylamide (PA) substrates of tunable Young&#x27;s modulus (E ). Feature fidelity is largely influenced by hydrogel swelling and most efficient on gels with a crosslinker concentration above 4.5%. However, this swelling does not affect the spacing of surface patterned ligands on two-dimensional PA gels. Bovine aortic endothelial cells (BAECs) cultured on linear micromolded features exhibit greater degrees of contact guidance with greater substrate E . Also described are applications of micromolding for future studies in cell mechanics.","abstract_has_math":false,"creators":["Charest, Jonathan"],"institution":"Cornell University","degree_name":"M.S., Biomedical Engineering","degree_level":"Master of Science","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["King, Cynthia A."],"committee_members":["Bonassar, Lawrence","Chu, Chih-Chang"],"year":2012,"date_issued":"2012-01-31","date_published":"2012-01-31","updated_at":"2026-11-19T03:14:48Z","subjects":["microfabrication","hydrogel","Youngs modulus"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["7745195"],"render_values":[{"text":"7745195","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/29334","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/29334","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F29334","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["King, Cynthia A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bonassar, Lawrence","Chu, Chih-Chang"]},{"key":"dc:creator","label":"Author","values":["Charest, Jonathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-06-28T20:57:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-06-01T06:00:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-01-31"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microfabrication","hydrogel","Youngs modulus"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["7745195"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/29334"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9cebaf64-0b9c-4591-9965-219f613f74ec\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Microfabrication Of Hydrogel Substrates Of Tunable Young'S Modulus</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2012-01-31</PublicationDate> <Authors> <Author> <DisplayName>Charest, Jonathan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfabrication</Keyword> <Keyword>hydrogel</Keyword> <Keyword>Youngs modulus</Keyword> <Abstract>Much is known about the effects of matrix stiffness and matrix topography on cell behavior, however they are seldom investigated in tandem. Presented and validated here is a micromolding method to introduce topographical features onto polyacrylamide (PA) substrates of tunable Young's modulus (E ). Feature fidelity is largely influenced by hydrogel swelling and most efficient on gels with a crosslinker concentration above 4.5%. However, this swelling does not affect the spacing of surface patterned ligands on two-dimensional PA gels. Bovine aortic endothelial cells (BAECs) cultured on linear micromolded features exhibit greater degrees of contact guidance with greater substrate E . Also described are applications of micromolding for future studies in cell mechanics.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Charest, Jonathan"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Much is known about the effects of matrix stiffness and matrix topography on cell behavior, however they are seldom investigated in tandem. Presented and validated here is a micromolding method to introduce topographical features onto polyacrylamide (PA) substrates of tunable Young's modulus (E ). Feature fidelity is largely influenced by hydrogel swelling and most efficient on gels with a crosslinker concentration above 4.5%. However, this swelling does not affect the spacing of surface patterned ligands on two-dimensional PA gels. Bovine aortic endothelial cells (BAECs) cultured on linear micromolded features exhibit greater degrees of contact guidance with greater substrate E . Also described are applications of micromolding for future studies in cell mechanics."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Microfabrication Of Hydrogel Substrates Of Tunable Young'S Modulus"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9cebaf64-0b9c-4591-9965-219f613f74ec\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Microfabrication Of Hydrogel Substrates Of Tunable Young'S Modulus</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2012-01-31</PublicationDate> <Authors> <Author> <DisplayName>Charest, Jonathan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfabrication</Keyword> <Keyword>hydrogel</Keyword> <Keyword>Youngs modulus</Keyword> <Abstract>Much is known about the effects of matrix stiffness and matrix topography on cell behavior, however they are seldom investigated in tandem. Presented and validated here is a micromolding method to introduce topographical features onto polyacrylamide (PA) substrates of tunable Young's modulus (E ). Feature fidelity is largely influenced by hydrogel swelling and most efficient on gels with a crosslinker concentration above 4.5%. However, this swelling does not affect the spacing of surface patterned ligands on two-dimensional PA gels. Bovine aortic endothelial cells (BAECs) cultured on linear micromolded features exhibit greater degrees of contact guidance with greater substrate E . Also described are applications of micromolding for future studies in cell mechanics.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Charest, Jonathan"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["King, Cynthia A."],"dc:contributor.committeemember":["Bonassar, Lawrence","Chu, Chih-Chang"],"dc:creator":["Charest, Jonathan"],"dc:date.accessioned":["2012-06-28T20:57:05Z"],"dc:date.available":["2017-06-01T06:00:26Z"],"dc:date.issued":["2012-01-31"],"dc:description.abstract":["Much is known about the effects of matrix stiffness and matrix topography on cell behavior, however they are seldom investigated in tandem. Presented and validated here is a micromolding method to introduce topographical features onto polyacrylamide (PA) substrates of tunable Young's modulus (E ). Feature fidelity is largely influenced by hydrogel swelling and most efficient on gels with a crosslinker concentration above 4.5%. However, this swelling does not affect the spacing of surface patterned ligands on two-dimensional PA gels. Bovine aortic endothelial cells (BAECs) cultured on linear micromolded features exhibit greater degrees of contact guidance with greater substrate E . Also described are applications of micromolding for future studies in cell mechanics."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["7745195"],"dc:identifier.uri":["https://hdl.handle.net/1813/29334"],"dc:language.iso":["en_US"],"dc:subject":["microfabrication","hydrogel","Youngs modulus"],"dc:title":["Microfabrication Of Hydrogel Substrates Of Tunable Young'S Modulus"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Biomedical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:14:48Z"}