{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/29486"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/29486","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Development Of Microfluidic Devices For Biopharmaceutical Production And Biotoxin Detection","abstract":"In this work, we present two different applications of microfluidic control. In the first application, we have developed a microfluidic device that has the potential to automate combinatorial protocols like protein refolding, impacting the biopharmaceutical industry. This device uses microfluidic valves and pumps that can be operated in an automated fashion for fluidic control. We performed refolding experiments on the protein [beta]-galactosidase and showed on-chip quantification of refolding yield using a fluorometric assay. In the second application, we have developed a microfluidic immunobiosensor with an integrated preconcentration system to improve the detection sensitivity. A nanoporous membrane fabricated in-situ using photopolymerization technique inside glass microchannels acts as the preconcentration system. Analytes were electrophoretically concentrated at the membrane and the concentrated bolus was eluted towards a detection region downstream. We performed proof-of-principle experiments using biotin-streptavidin binding to show the improvement in detection sensitivity of this device as opposed to a device that does not include a preconcentration system. Using this device, we also showed a detection limit of 1.6 X 105 PFU/ml for Feline Calicivirus (FCV), which is a model system for human enteric virus. This device has potential to serve as an early detection system for such enteric viruses in environmental water samples.","abstract_html":"In this work, we present two different applications of microfluidic control. In the first application, we have developed a microfluidic device that has the potential to automate combinatorial protocols like protein refolding, impacting the biopharmaceutical industry. This device uses microfluidic valves and pumps that can be operated in an automated fashion for fluidic control. We performed refolding experiments on the protein [beta]-galactosidase and showed on-chip quantification of refolding yield using a fluorometric assay. In the second application, we have developed a microfluidic immunobiosensor with an integrated preconcentration system to improve the detection sensitivity. A nanoporous membrane fabricated in-situ using photopolymerization technique inside glass microchannels acts as the preconcentration system. Analytes were electrophoretically concentrated at the membrane and the concentrated bolus was eluted towards a detection region downstream. We performed proof-of-principle experiments using biotin-streptavidin binding to show the improvement in detection sensitivity of this device as opposed to a device that does not include a preconcentration system. Using this device, we also showed a detection limit of 1.6 X 105 PFU/ml for Feline Calicivirus (FCV), which is a model system for human enteric virus. This device has potential to serve as an early detection system for such enteric viruses in environmental water samples.","abstract_has_math":false,"creators":["Kondapalli, Sowmya"],"institution":"Cornell University","degree_name":"Ph. D., Mechanical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kirby, Brian"],"committee_members":["Baeumner, Antje J","Collins, Lance"],"year":2011,"date_issued":"2011-05-31","date_published":"2011-05-31","updated_at":"2026-11-19T03:15:03Z","subjects":["Microfluidic devices","Combinatorial protein refolding","Biosensors for virus detection"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["7745404"],"render_values":[{"text":"7745404","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/29486","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/29486","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F29486","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Kirby, Brian"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Baeumner, Antje J","Collins, Lance"]},{"key":"dc:creator","label":"Author","values":["Kondapalli, Sowmya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-06-28T20:57:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-29T05:36:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-05-31"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidic devices","Combinatorial protein refolding","Biosensors for virus detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["7745404"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/29486"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a0906398-cd0c-4dd5-ab53-c86edb270abe\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development Of Microfluidic Devices For Biopharmaceutical Production And Biotoxin Detection</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011-05-31</PublicationDate> <Authors> <Author> <DisplayName>Kondapalli, Sowmya</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Microfluidic devices</Keyword> <Keyword>Combinatorial protein refolding</Keyword> <Keyword>Biosensors for virus detection</Keyword> <Abstract>In this work, we present two different applications of microfluidic control. In the first application, we have developed a microfluidic device that has the potential to automate combinatorial protocols like protein refolding, impacting the biopharmaceutical industry. This device uses microfluidic valves and pumps that can be operated in an automated fashion for fluidic control. We performed refolding experiments on the protein [beta]-galactosidase and showed on-chip quantification of refolding yield using a fluorometric assay. In the second application, we have developed a microfluidic immunobiosensor with an integrated preconcentration system to improve the detection sensitivity. A nanoporous membrane fabricated in-situ using photopolymerization technique inside glass microchannels acts as the preconcentration system. Analytes were electrophoretically concentrated at the membrane and the concentrated bolus was eluted towards a detection region downstream. We performed proof-of-principle experiments using biotin-streptavidin binding to show the improvement in detection sensitivity of this device as opposed to a device that does not include a preconcentration system. Using this device, we also showed a detection limit of 1.6 X 105 PFU/ml for Feline Calicivirus (FCV), which is a model system for human enteric virus. This device has potential to serve as an early detection system for such enteric viruses in environmental water samples.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Kondapalli, Sowmya"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["In this work, we present two different applications of microfluidic control. In the first application, we have developed a microfluidic device that has the potential to automate combinatorial protocols like protein refolding, impacting the biopharmaceutical industry. This device uses microfluidic valves and pumps that can be operated in an automated fashion for fluidic control. We performed refolding experiments on the protein [beta]-galactosidase and showed on-chip quantification of refolding yield using a fluorometric assay. In the second application, we have developed a microfluidic immunobiosensor with an integrated preconcentration system to improve the detection sensitivity. A nanoporous membrane fabricated in-situ using photopolymerization technique inside glass microchannels acts as the preconcentration system. Analytes were electrophoretically concentrated at the membrane and the concentrated bolus was eluted towards a detection region downstream. We performed proof-of-principle experiments using biotin-streptavidin binding to show the improvement in detection sensitivity of this device as opposed to a device that does not include a preconcentration system. Using this device, we also showed a detection limit of 1.6 X 105 PFU/ml for Feline Calicivirus (FCV), which is a model system for human enteric virus. This device has potential to serve as an early detection system for such enteric viruses in environmental water samples."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development Of Microfluidic Devices For Biopharmaceutical Production And Biotoxin Detection"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a0906398-cd0c-4dd5-ab53-c86edb270abe\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development Of Microfluidic Devices For Biopharmaceutical Production And Biotoxin Detection</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011-05-31</PublicationDate> <Authors> <Author> <DisplayName>Kondapalli, Sowmya</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Microfluidic devices</Keyword> <Keyword>Combinatorial protein refolding</Keyword> <Keyword>Biosensors for virus detection</Keyword> <Abstract>In this work, we present two different applications of microfluidic control. In the first application, we have developed a microfluidic device that has the potential to automate combinatorial protocols like protein refolding, impacting the biopharmaceutical industry. This device uses microfluidic valves and pumps that can be operated in an automated fashion for fluidic control. We performed refolding experiments on the protein [beta]-galactosidase and showed on-chip quantification of refolding yield using a fluorometric assay. In the second application, we have developed a microfluidic immunobiosensor with an integrated preconcentration system to improve the detection sensitivity. A nanoporous membrane fabricated in-situ using photopolymerization technique inside glass microchannels acts as the preconcentration system. Analytes were electrophoretically concentrated at the membrane and the concentrated bolus was eluted towards a detection region downstream. We performed proof-of-principle experiments using biotin-streptavidin binding to show the improvement in detection sensitivity of this device as opposed to a device that does not include a preconcentration system. Using this device, we also showed a detection limit of 1.6 X 105 PFU/ml for Feline Calicivirus (FCV), which is a model system for human enteric virus. This device has potential to serve as an early detection system for such enteric viruses in environmental water samples.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Kondapalli, Sowmya"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Kirby, Brian"],"dc:contributor.committeemember":["Baeumner, Antje J","Collins, Lance"],"dc:creator":["Kondapalli, Sowmya"],"dc:date.accessioned":["2012-06-28T20:57:36Z"],"dc:date.available":["2016-09-29T05:36:49Z"],"dc:date.issued":["2011-05-31"],"dc:description.abstract":["In this work, we present two different applications of microfluidic control. In the first application, we have developed a microfluidic device that has the potential to automate combinatorial protocols like protein refolding, impacting the biopharmaceutical industry. This device uses microfluidic valves and pumps that can be operated in an automated fashion for fluidic control. We performed refolding experiments on the protein [beta]-galactosidase and showed on-chip quantification of refolding yield using a fluorometric assay. In the second application, we have developed a microfluidic immunobiosensor with an integrated preconcentration system to improve the detection sensitivity. A nanoporous membrane fabricated in-situ using photopolymerization technique inside glass microchannels acts as the preconcentration system. Analytes were electrophoretically concentrated at the membrane and the concentrated bolus was eluted towards a detection region downstream. We performed proof-of-principle experiments using biotin-streptavidin binding to show the improvement in detection sensitivity of this device as opposed to a device that does not include a preconcentration system. Using this device, we also showed a detection limit of 1.6 X 105 PFU/ml for Feline Calicivirus (FCV), which is a model system for human enteric virus. This device has potential to serve as an early detection system for such enteric viruses in environmental water samples."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["7745404"],"dc:identifier.uri":["https://hdl.handle.net/1813/29486"],"dc:language.iso":["en_US"],"dc:subject":["Microfluidic devices","Combinatorial protein refolding","Biosensors for virus detection"],"dc:title":["Development Of Microfluidic Devices For Biopharmaceutical Production And Biotoxin Detection"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:15:03Z"}