{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/33630"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/33630","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Computer-Aided Detection Of Pulmonary Nodules From Ct Scans","abstract":"Lung cancer is the leading cause of cancer related death in the world. Computed tomography (CT), which can provide detailed images of lung structure, makes it possible to detect lung cancer in its early stage. Regular clinical practice involves visual inspection of hundreds cross-sectional slices of a patient's CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection performance can be improved significantly by employing a computer algorithm for pulmonary nodule identification. This dissertation is devoted to the topic of computer-aided detection (CAD) of pulmonary nodules from chest CT scans. The thesis includes several subtopics: system architecture, optimization and validation of the detection system. Among the major contributions to the topic are: design and development of a multiscale Laplacian of Gaussian-based candidate generation system, high specificity standard moments-based pulmonary vessel bifurcation filter, nonsolid nodule detection system, and a new detection system validation procedure that compensates for size measurement error and provides a more meaningful performance assessment for CAD systems. In addition, a large size-enriched dataset for CAD system evaluation was created to become a valuable resource for future research.","abstract_html":"Lung cancer is the leading cause of cancer related death in the world. Computed tomography (CT), which can provide detailed images of lung structure, makes it possible to detect lung cancer in its early stage. Regular clinical practice involves visual inspection of hundreds cross-sectional slices of a patient&#x27;s CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection performance can be improved significantly by employing a computer algorithm for pulmonary nodule identification. This dissertation is devoted to the topic of computer-aided detection (CAD) of pulmonary nodules from chest CT scans. The thesis includes several subtopics: system architecture, optimization and validation of the detection system. Among the major contributions to the topic are: design and development of a multiscale Laplacian of Gaussian-based candidate generation system, high specificity standard moments-based pulmonary vessel bifurcation filter, nonsolid nodule detection system, and a new detection system validation procedure that compensates for size measurement error and provides a more meaningful performance assessment for CAD systems. In addition, a large size-enriched dataset for CAD system evaluation was created to become a valuable resource for future research.","abstract_has_math":false,"creators":["Fotin, Sergey"],"institution":"Cornell University","degree_name":"Ph. D., Electrical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Reeves, Anthony P"],"committee_members":["Snavely, Keith Noah","Doerschuk, Peter"],"year":2011,"date_issued":"2011-05-29","date_published":"2011-05-29","updated_at":"2026-11-19T03:15:57Z","subjects":["Computer-aided detection","Pulmonary nodules","Computed tomography"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8213934"],"render_values":[{"text":"8213934","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/33630","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/33630","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F33630","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Reeves, Anthony P"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Snavely, Keith Noah","Doerschuk, Peter"]},{"key":"dc:creator","label":"Author","values":["Fotin, Sergey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-07-23T18:24:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-27T05:39:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-05-29"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer-aided detection","Pulmonary nodules","Computed tomography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8213934"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/33630"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"bf3c097e-f351-4d01-a076-ae23489b5856\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Computer-Aided Detection Of Pulmonary Nodules From Ct Scans</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011-05-29</PublicationDate> <Authors> <Author> <DisplayName>Fotin, Sergey</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Computer-aided detection</Keyword> <Keyword>Pulmonary nodules</Keyword> <Keyword>Computed tomography</Keyword> <Abstract>Lung cancer is the leading cause of cancer related death in the world. Computed tomography (CT), which can provide detailed images of lung structure, makes it possible to detect lung cancer in its early stage. Regular clinical practice involves visual inspection of hundreds cross-sectional slices of a patient's CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection performance can be improved significantly by employing a computer algorithm for pulmonary nodule identification. This dissertation is devoted to the topic of computer-aided detection (CAD) of pulmonary nodules from chest CT scans. The thesis includes several subtopics: system architecture, optimization and validation of the detection system. Among the major contributions to the topic are: design and development of a multiscale Laplacian of Gaussian-based candidate generation system, high specificity standard moments-based pulmonary vessel bifurcation filter, nonsolid nodule detection system, and a new detection system validation procedure that compensates for size measurement error and provides a more meaningful performance assessment for CAD systems. In addition, a large size-enriched dataset for CAD system evaluation was created to become a valuable resource for future research.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Fotin, Sergey"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Lung cancer is the leading cause of cancer related death in the world. Computed tomography (CT), which can provide detailed images of lung structure, makes it possible to detect lung cancer in its early stage. Regular clinical practice involves visual inspection of hundreds cross-sectional slices of a patient's CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection performance can be improved significantly by employing a computer algorithm for pulmonary nodule identification. This dissertation is devoted to the topic of computer-aided detection (CAD) of pulmonary nodules from chest CT scans. The thesis includes several subtopics: system architecture, optimization and validation of the detection system. Among the major contributions to the topic are: design and development of a multiscale Laplacian of Gaussian-based candidate generation system, high specificity standard moments-based pulmonary vessel bifurcation filter, nonsolid nodule detection system, and a new detection system validation procedure that compensates for size measurement error and provides a more meaningful performance assessment for CAD systems. In addition, a large size-enriched dataset for CAD system evaluation was created to become a valuable resource for future research."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Computer-Aided Detection Of Pulmonary Nodules From Ct Scans"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"bf3c097e-f351-4d01-a076-ae23489b5856\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Computer-Aided Detection Of Pulmonary Nodules From Ct Scans</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011-05-29</PublicationDate> <Authors> <Author> <DisplayName>Fotin, Sergey</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Computer-aided detection</Keyword> <Keyword>Pulmonary nodules</Keyword> <Keyword>Computed tomography</Keyword> <Abstract>Lung cancer is the leading cause of cancer related death in the world. Computed tomography (CT), which can provide detailed images of lung structure, makes it possible to detect lung cancer in its early stage. Regular clinical practice involves visual inspection of hundreds cross-sectional slices of a patient's CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection performance can be improved significantly by employing a computer algorithm for pulmonary nodule identification. This dissertation is devoted to the topic of computer-aided detection (CAD) of pulmonary nodules from chest CT scans. The thesis includes several subtopics: system architecture, optimization and validation of the detection system. Among the major contributions to the topic are: design and development of a multiscale Laplacian of Gaussian-based candidate generation system, high specificity standard moments-based pulmonary vessel bifurcation filter, nonsolid nodule detection system, and a new detection system validation procedure that compensates for size measurement error and provides a more meaningful performance assessment for CAD systems. In addition, a large size-enriched dataset for CAD system evaluation was created to become a valuable resource for future research.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Fotin, Sergey"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Reeves, Anthony P"],"dc:contributor.committeemember":["Snavely, Keith Noah","Doerschuk, Peter"],"dc:creator":["Fotin, Sergey"],"dc:date.accessioned":["2013-07-23T18:24:06Z"],"dc:date.available":["2016-09-27T05:39:46Z"],"dc:date.issued":["2011-05-29"],"dc:description.abstract":["Lung cancer is the leading cause of cancer related death in the world. Computed tomography (CT), which can provide detailed images of lung structure, makes it possible to detect lung cancer in its early stage. Regular clinical practice involves visual inspection of hundreds cross-sectional slices of a patient's CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection performance can be improved significantly by employing a computer algorithm for pulmonary nodule identification. This dissertation is devoted to the topic of computer-aided detection (CAD) of pulmonary nodules from chest CT scans. The thesis includes several subtopics: system architecture, optimization and validation of the detection system. Among the major contributions to the topic are: design and development of a multiscale Laplacian of Gaussian-based candidate generation system, high specificity standard moments-based pulmonary vessel bifurcation filter, nonsolid nodule detection system, and a new detection system validation procedure that compensates for size measurement error and provides a more meaningful performance assessment for CAD systems. In addition, a large size-enriched dataset for CAD system evaluation was created to become a valuable resource for future research."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8213934"],"dc:identifier.uri":["https://hdl.handle.net/1813/33630"],"dc:language.iso":["en_US"],"dc:subject":["Computer-aided detection","Pulmonary nodules","Computed tomography"],"dc:title":["Computer-Aided Detection Of Pulmonary Nodules From Ct Scans"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Electrical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:15:57Z"}