{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/33643"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/33643","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Transient Electrokinetic Phenomena In Hydrophobic Microfluidic Substrates","abstract":"In this work we characterize electrokinetics in hydrophobic microfluidic substrates with aqueous working solutions as a function of the history of the fluid-solid interface. We utilize time-resolved streaming potential and current monitoring experiments to show that the electrokinetic potential in Zeonor and TOPAS substrates is a function of time after (i) initial formation of the fluid-solid interface, and (ii) after ethanol-water solvent exchanges. In these systems, the electrokinetic potential is initially large in magnitude, and decays exponentially with a time constant that is on the order of hours. We further show that the kinetics of the decay are affected by exposure to electric fields, and the ambient pressure of air surrounding the system. These data suggest that the state of dissolved gases in solution must be considered among the parameters that affect the electrokinetic potential of hydrophobic surfaces with aqueous solutions.","abstract_html":"In this work we characterize electrokinetics in hydrophobic microfluidic substrates with aqueous working solutions as a function of the history of the fluid-solid interface. We utilize time-resolved streaming potential and current monitoring experiments to show that the electrokinetic potential in Zeonor and TOPAS substrates is a function of time after (i) initial formation of the fluid-solid interface, and (ii) after ethanol-water solvent exchanges. In these systems, the electrokinetic potential is initially large in magnitude, and decays exponentially with a time constant that is on the order of hours. We further show that the kinetics of the decay are affected by exposure to electric fields, and the ambient pressure of air surrounding the system. These data suggest that the state of dissolved gases in solution must be considered among the parameters that affect the electrokinetic potential of hydrophobic surfaces with aqueous solutions.","abstract_has_math":false,"creators":["Tandon, Vishal"],"institution":"Cornell University","degree_name":"Ph. D., Biomedical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kirby, Brian"],"committee_members":["Feigenson, Gerald W","Stroock, Abraham Duncan"],"year":2011,"date_issued":"2011-05-29","date_published":"2011-05-29","updated_at":"2026-11-19T03:15:57Z","subjects":["microfluidics","zeta potential","electrokinetic"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8213953"],"render_values":[{"text":"8213953","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/33643","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/33643","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F33643","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Kirby, Brian"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Feigenson, Gerald W","Stroock, Abraham Duncan"]},{"key":"dc:creator","label":"Author","values":["Tandon, Vishal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-07-23T18:24:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-27T05:39:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-05-29"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microfluidics","zeta potential","electrokinetic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8213953"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/33643"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b497eee7-898d-4740-a2fa-6869d7b3f10a\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Transient Electrokinetic Phenomena In Hydrophobic Microfluidic Substrates</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011-05-29</PublicationDate> <Authors> <Author> <DisplayName>Tandon, Vishal</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfluidics</Keyword> <Keyword>zeta potential</Keyword> <Keyword>electrokinetic</Keyword> <Abstract>In this work we characterize electrokinetics in hydrophobic microfluidic substrates with aqueous working solutions as a function of the history of the fluid-solid interface. We utilize time-resolved streaming potential and current monitoring experiments to show that the electrokinetic potential in Zeonor and TOPAS substrates is a function of time after (i) initial formation of the fluid-solid interface, and (ii) after ethanol-water solvent exchanges. In these systems, the electrokinetic potential is initially large in magnitude, and decays exponentially with a time constant that is on the order of hours. We further show that the kinetics of the decay are affected by exposure to electric fields, and the ambient pressure of air surrounding the system. These data suggest that the state of dissolved gases in solution must be considered among the parameters that affect the electrokinetic potential of hydrophobic surfaces with aqueous solutions.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Tandon, Vishal"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["In this work we characterize electrokinetics in hydrophobic microfluidic substrates with aqueous working solutions as a function of the history of the fluid-solid interface. We utilize time-resolved streaming potential and current monitoring experiments to show that the electrokinetic potential in Zeonor and TOPAS substrates is a function of time after (i) initial formation of the fluid-solid interface, and (ii) after ethanol-water solvent exchanges. In these systems, the electrokinetic potential is initially large in magnitude, and decays exponentially with a time constant that is on the order of hours. We further show that the kinetics of the decay are affected by exposure to electric fields, and the ambient pressure of air surrounding the system. These data suggest that the state of dissolved gases in solution must be considered among the parameters that affect the electrokinetic potential of hydrophobic surfaces with aqueous solutions."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Transient Electrokinetic Phenomena In Hydrophobic Microfluidic Substrates"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b497eee7-898d-4740-a2fa-6869d7b3f10a\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Transient Electrokinetic Phenomena In Hydrophobic Microfluidic Substrates</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011-05-29</PublicationDate> <Authors> <Author> <DisplayName>Tandon, Vishal</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfluidics</Keyword> <Keyword>zeta potential</Keyword> <Keyword>electrokinetic</Keyword> <Abstract>In this work we characterize electrokinetics in hydrophobic microfluidic substrates with aqueous working solutions as a function of the history of the fluid-solid interface. We utilize time-resolved streaming potential and current monitoring experiments to show that the electrokinetic potential in Zeonor and TOPAS substrates is a function of time after (i) initial formation of the fluid-solid interface, and (ii) after ethanol-water solvent exchanges. In these systems, the electrokinetic potential is initially large in magnitude, and decays exponentially with a time constant that is on the order of hours. We further show that the kinetics of the decay are affected by exposure to electric fields, and the ambient pressure of air surrounding the system. These data suggest that the state of dissolved gases in solution must be considered among the parameters that affect the electrokinetic potential of hydrophobic surfaces with aqueous solutions.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Tandon, Vishal"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Kirby, Brian"],"dc:contributor.committeemember":["Feigenson, Gerald W","Stroock, Abraham Duncan"],"dc:creator":["Tandon, Vishal"],"dc:date.accessioned":["2013-07-23T18:24:10Z"],"dc:date.available":["2016-09-27T05:39:50Z"],"dc:date.issued":["2011-05-29"],"dc:description.abstract":["In this work we characterize electrokinetics in hydrophobic microfluidic substrates with aqueous working solutions as a function of the history of the fluid-solid interface. We utilize time-resolved streaming potential and current monitoring experiments to show that the electrokinetic potential in Zeonor and TOPAS substrates is a function of time after (i) initial formation of the fluid-solid interface, and (ii) after ethanol-water solvent exchanges. In these systems, the electrokinetic potential is initially large in magnitude, and decays exponentially with a time constant that is on the order of hours. We further show that the kinetics of the decay are affected by exposure to electric fields, and the ambient pressure of air surrounding the system. These data suggest that the state of dissolved gases in solution must be considered among the parameters that affect the electrokinetic potential of hydrophobic surfaces with aqueous solutions."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8213953"],"dc:identifier.uri":["https://hdl.handle.net/1813/33643"],"dc:language.iso":["en_US"],"dc:subject":["microfluidics","zeta potential","electrokinetic"],"dc:title":["Transient Electrokinetic Phenomena In Hydrophobic Microfluidic Substrates"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Biomedical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:15:57Z"}