{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/33804"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/33804","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Automated Methods For Pulmonary Nodule Growth Rate Measurement: Early Computer-Aided Diagnosis Of Lung Cancer From Computed Tomography Images","abstract":"Pulmonary nodules are visible as dense, opaque areas in the lung on computed tomography (CT) images and may be early indications of lung cancer. Pulmonary nodule growth rate is highly correlated with malignancy and therefore its evaluation is useful in clinical decision making. Automated methods have been developed for nodule growth rate measurements, but these methods exhibit large measurement error; reducing this error will enable radiologists to make better decisions regarding follow up and treatment, in turn improving patient outcomes. Four major aspects of pulmonary nodule measurement are addressed in this thesis. A formal procedure for the comparative evaluation of different computer algorithms for pulmonary nodule change measurement has been developed that involves a standardized set of 50 CT image pairs and an analysis method. This procedure for the first time addresses the need to be able to quantitatively compare the performance of different methods. A study has been conducted in which developers of 18 computer methods participated and the results form a baseline with which to compare current and future algorithms. Two different computer algorithm approaches were developed to reduce the uncertainty in growth rate measurements. The first approach, moment-based compensation (ZCOMP) was performed on segmented nodule images to address additional observed increased error in the z-direction compared to the xyplane. By applying ZCOMP, volumetric measurement variability was reduced from a 95% limits of agreement of (-24.0%, 18.2%) to (-12.4%, 12.7%) on zerochange nodules imaged on thin-slice scans of the same resolution. The second approach was developed to address difficult-to-segment nodules with complex shapes and attachments. Instead of explicitly segmenting the nodule from the lung parenchyma, the growth index from density method (GID ) uses the density change in a region of interest as a surrogate growth measure. The GID method had much lower variation, (-11.0%, 12.3%) compared to a volumetric segmentation method, (-25.2%, 18.6%). Finally, an automated method was developed for measuring murine pulmonary nodule growth from micro-CT scans, adapting work from methods developed for human patients. This provides improved accuracy for lesion growth measurements used in small animal pre-clinical studies. The method addresses the additional noise, lack of contrast, and poor calibration of micro-CT scans. The measured growth rate was compared to the exponential growth model, and on a dataset of six nodules with repeat scans, the method measured growth that was consistent with the model.","abstract_html":"Pulmonary nodules are visible as dense, opaque areas in the lung on computed tomography (CT) images and may be early indications of lung cancer. Pulmonary nodule growth rate is highly correlated with malignancy and therefore its evaluation is useful in clinical decision making. Automated methods have been developed for nodule growth rate measurements, but these methods exhibit large measurement error; reducing this error will enable radiologists to make better decisions regarding follow up and treatment, in turn improving patient outcomes. Four major aspects of pulmonary nodule measurement are addressed in this thesis. A formal procedure for the comparative evaluation of different computer algorithms for pulmonary nodule change measurement has been developed that involves a standardized set of 50 CT image pairs and an analysis method. This procedure for the first time addresses the need to be able to quantitatively compare the performance of different methods. A study has been conducted in which developers of 18 computer methods participated and the results form a baseline with which to compare current and future algorithms. Two different computer algorithm approaches were developed to reduce the uncertainty in growth rate measurements. The first approach, moment-based compensation (ZCOMP) was performed on segmented nodule images to address additional observed increased error in the z-direction compared to the xyplane. By applying ZCOMP, volumetric measurement variability was reduced from a 95% limits of agreement of (-24.0%, 18.2%) to (-12.4%, 12.7%) on zerochange nodules imaged on thin-slice scans of the same resolution. The second approach was developed to address difficult-to-segment nodules with complex shapes and attachments. Instead of explicitly segmenting the nodule from the lung parenchyma, the growth index from density method (GID ) uses the density change in a region of interest as a surrogate growth measure. The GID method had much lower variation, (-11.0%, 12.3%) compared to a volumetric segmentation method, (-25.2%, 18.6%). Finally, an automated method was developed for measuring murine pulmonary nodule growth from micro-CT scans, adapting work from methods developed for human patients. This provides improved accuracy for lesion growth measurements used in small animal pre-clinical studies. The method addresses the additional noise, lack of contrast, and poor calibration of micro-CT scans. The measured growth rate was compared to the exponential growth model, and on a dataset of six nodules with repeat scans, the method measured growth that was consistent with the model.","abstract_has_math":false,"creators":["Jirapatnakul, Artit"],"institution":"Cornell University","degree_name":"Ph. D., Electrical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Reeves, Anthony P"],"committee_members":["Doerschuk, Peter","Snavely, Keith Noah"],"year":2013,"date_issued":"2013-01-28","date_published":"2013-01-28","updated_at":"2026-11-19T03:16:49Z","subjects":["pulmonary nodule","growth rate","computer-aided diagnosis"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8266963"],"render_values":[{"text":"8266963","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/33804","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/33804","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F33804","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Reeves, Anthony P"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Doerschuk, Peter","Snavely, Keith Noah"]},{"key":"dc:creator","label":"Author","values":["Jirapatnakul, Artit"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-05T15:25:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-29T07:00:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-01-28"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["pulmonary nodule","growth rate","computer-aided diagnosis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8266963"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/33804"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"823c78d7-133b-44c5-9c16-368816406b5f\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Automated Methods For Pulmonary Nodule Growth Rate Measurement: Early Computer-Aided Diagnosis Of Lung Cancer From Computed Tomography Images</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013-01-28</PublicationDate> <Authors> <Author> <DisplayName>Jirapatnakul, Artit</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>pulmonary nodule</Keyword> <Keyword>growth rate</Keyword> <Keyword>computer-aided diagnosis</Keyword> <Abstract>Pulmonary nodules are visible as dense, opaque areas in the lung on computed tomography (CT) images and may be early indications of lung cancer. Pulmonary nodule growth rate is highly correlated with malignancy and therefore its evaluation is useful in clinical decision making. Automated methods have been developed for nodule growth rate measurements, but these methods exhibit large measurement error; reducing this error will enable radiologists to make better decisions regarding follow up and treatment, in turn improving patient outcomes. Four major aspects of pulmonary nodule measurement are addressed in this thesis. A formal procedure for the comparative evaluation of different computer algorithms for pulmonary nodule change measurement has been developed that involves a standardized set of 50 CT image pairs and an analysis method. This procedure for the first time addresses the need to be able to quantitatively compare the performance of different methods. A study has been conducted in which developers of 18 computer methods participated and the results form a baseline with which to compare current and future algorithms. Two different computer algorithm approaches were developed to reduce the uncertainty in growth rate measurements. The first approach, moment-based compensation (ZCOMP) was performed on segmented nodule images to address additional observed increased error in the z-direction compared to the xyplane. By applying ZCOMP, volumetric measurement variability was reduced from a 95% limits of agreement of (-24.0%, 18.2%) to (-12.4%, 12.7%) on zerochange nodules imaged on thin-slice scans of the same resolution. The second approach was developed to address difficult-to-segment nodules with complex shapes and attachments. Instead of explicitly segmenting the nodule from the lung parenchyma, the growth index from density method (GID ) uses the density change in a region of interest as a surrogate growth measure. The GID method had much lower variation, (-11.0%, 12.3%) compared to a volumetric segmentation method, (-25.2%, 18.6%). Finally, an automated method was developed for measuring murine pulmonary nodule growth from micro-CT scans, adapting work from methods developed for human patients. This provides improved accuracy for lesion growth measurements used in small animal pre-clinical studies. The method addresses the additional noise, lack of contrast, and poor calibration of micro-CT scans. The measured growth rate was compared to the exponential growth model, and on a dataset of six nodules with repeat scans, the method measured growth that was consistent with the model.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Jirapatnakul, Artit"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Pulmonary nodules are visible as dense, opaque areas in the lung on computed tomography (CT) images and may be early indications of lung cancer. Pulmonary nodule growth rate is highly correlated with malignancy and therefore its evaluation is useful in clinical decision making. Automated methods have been developed for nodule growth rate measurements, but these methods exhibit large measurement error; reducing this error will enable radiologists to make better decisions regarding follow up and treatment, in turn improving patient outcomes. Four major aspects of pulmonary nodule measurement are addressed in this thesis. A formal procedure for the comparative evaluation of different computer algorithms for pulmonary nodule change measurement has been developed that involves a standardized set of 50 CT image pairs and an analysis method. This procedure for the first time addresses the need to be able to quantitatively compare the performance of different methods. A study has been conducted in which developers of 18 computer methods participated and the results form a baseline with which to compare current and future algorithms. Two different computer algorithm approaches were developed to reduce the uncertainty in growth rate measurements. The first approach, moment-based compensation (ZCOMP) was performed on segmented nodule images to address additional observed increased error in the z-direction compared to the xyplane. By applying ZCOMP, volumetric measurement variability was reduced from a 95% limits of agreement of (-24.0%, 18.2%) to (-12.4%, 12.7%) on zerochange nodules imaged on thin-slice scans of the same resolution. The second approach was developed to address difficult-to-segment nodules with complex shapes and attachments. Instead of explicitly segmenting the nodule from the lung parenchyma, the growth index from density method (GID ) uses the density change in a region of interest as a surrogate growth measure. The GID method had much lower variation, (-11.0%, 12.3%) compared to a volumetric segmentation method, (-25.2%, 18.6%). Finally, an automated method was developed for measuring murine pulmonary nodule growth from micro-CT scans, adapting work from methods developed for human patients. This provides improved accuracy for lesion growth measurements used in small animal pre-clinical studies. The method addresses the additional noise, lack of contrast, and poor calibration of micro-CT scans. The measured growth rate was compared to the exponential growth model, and on a dataset of six nodules with repeat scans, the method measured growth that was consistent with the model."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Automated Methods For Pulmonary Nodule Growth Rate Measurement: Early Computer-Aided Diagnosis Of Lung Cancer From Computed Tomography Images"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"823c78d7-133b-44c5-9c16-368816406b5f\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Automated Methods For Pulmonary Nodule Growth Rate Measurement: Early Computer-Aided Diagnosis Of Lung Cancer From Computed Tomography Images</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013-01-28</PublicationDate> <Authors> <Author> <DisplayName>Jirapatnakul, Artit</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>pulmonary nodule</Keyword> <Keyword>growth rate</Keyword> <Keyword>computer-aided diagnosis</Keyword> <Abstract>Pulmonary nodules are visible as dense, opaque areas in the lung on computed tomography (CT) images and may be early indications of lung cancer. Pulmonary nodule growth rate is highly correlated with malignancy and therefore its evaluation is useful in clinical decision making. Automated methods have been developed for nodule growth rate measurements, but these methods exhibit large measurement error; reducing this error will enable radiologists to make better decisions regarding follow up and treatment, in turn improving patient outcomes. Four major aspects of pulmonary nodule measurement are addressed in this thesis. A formal procedure for the comparative evaluation of different computer algorithms for pulmonary nodule change measurement has been developed that involves a standardized set of 50 CT image pairs and an analysis method. This procedure for the first time addresses the need to be able to quantitatively compare the performance of different methods. A study has been conducted in which developers of 18 computer methods participated and the results form a baseline with which to compare current and future algorithms. Two different computer algorithm approaches were developed to reduce the uncertainty in growth rate measurements. The first approach, moment-based compensation (ZCOMP) was performed on segmented nodule images to address additional observed increased error in the z-direction compared to the xyplane. By applying ZCOMP, volumetric measurement variability was reduced from a 95% limits of agreement of (-24.0%, 18.2%) to (-12.4%, 12.7%) on zerochange nodules imaged on thin-slice scans of the same resolution. The second approach was developed to address difficult-to-segment nodules with complex shapes and attachments. Instead of explicitly segmenting the nodule from the lung parenchyma, the growth index from density method (GID ) uses the density change in a region of interest as a surrogate growth measure. The GID method had much lower variation, (-11.0%, 12.3%) compared to a volumetric segmentation method, (-25.2%, 18.6%). Finally, an automated method was developed for measuring murine pulmonary nodule growth from micro-CT scans, adapting work from methods developed for human patients. This provides improved accuracy for lesion growth measurements used in small animal pre-clinical studies. The method addresses the additional noise, lack of contrast, and poor calibration of micro-CT scans. The measured growth rate was compared to the exponential growth model, and on a dataset of six nodules with repeat scans, the method measured growth that was consistent with the model.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Jirapatnakul, Artit"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Reeves, Anthony P"],"dc:contributor.committeemember":["Doerschuk, Peter","Snavely, Keith Noah"],"dc:creator":["Jirapatnakul, Artit"],"dc:date.accessioned":["2013-09-05T15:25:38Z"],"dc:date.available":["2018-01-29T07:00:36Z"],"dc:date.issued":["2013-01-28"],"dc:description.abstract":["Pulmonary nodules are visible as dense, opaque areas in the lung on computed tomography (CT) images and may be early indications of lung cancer. Pulmonary nodule growth rate is highly correlated with malignancy and therefore its evaluation is useful in clinical decision making. Automated methods have been developed for nodule growth rate measurements, but these methods exhibit large measurement error; reducing this error will enable radiologists to make better decisions regarding follow up and treatment, in turn improving patient outcomes. Four major aspects of pulmonary nodule measurement are addressed in this thesis. A formal procedure for the comparative evaluation of different computer algorithms for pulmonary nodule change measurement has been developed that involves a standardized set of 50 CT image pairs and an analysis method. This procedure for the first time addresses the need to be able to quantitatively compare the performance of different methods. A study has been conducted in which developers of 18 computer methods participated and the results form a baseline with which to compare current and future algorithms. Two different computer algorithm approaches were developed to reduce the uncertainty in growth rate measurements. The first approach, moment-based compensation (ZCOMP) was performed on segmented nodule images to address additional observed increased error in the z-direction compared to the xyplane. By applying ZCOMP, volumetric measurement variability was reduced from a 95% limits of agreement of (-24.0%, 18.2%) to (-12.4%, 12.7%) on zerochange nodules imaged on thin-slice scans of the same resolution. The second approach was developed to address difficult-to-segment nodules with complex shapes and attachments. Instead of explicitly segmenting the nodule from the lung parenchyma, the growth index from density method (GID ) uses the density change in a region of interest as a surrogate growth measure. The GID method had much lower variation, (-11.0%, 12.3%) compared to a volumetric segmentation method, (-25.2%, 18.6%). Finally, an automated method was developed for measuring murine pulmonary nodule growth from micro-CT scans, adapting work from methods developed for human patients. This provides improved accuracy for lesion growth measurements used in small animal pre-clinical studies. The method addresses the additional noise, lack of contrast, and poor calibration of micro-CT scans. The measured growth rate was compared to the exponential growth model, and on a dataset of six nodules with repeat scans, the method measured growth that was consistent with the model."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8266963"],"dc:identifier.uri":["https://hdl.handle.net/1813/33804"],"dc:language.iso":["en_US"],"dc:subject":["pulmonary nodule","growth rate","computer-aided diagnosis"],"dc:title":["Automated Methods For Pulmonary Nodule Growth Rate Measurement: Early Computer-Aided Diagnosis Of Lung Cancer From Computed Tomography Images"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Electrical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:16:49Z"}