{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/34293"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/34293","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Methods Of Measuring Microscopic Tissue Damage In Cancellous Bone: Sampling And Statistical Power","abstract":"Microscopic tissue damage can occur in bone as a result of an isolated overload leading to reduces bone strength under subsequent loads. In addition, microscopic tissue damage is believed to stimulate bone resorption and bone loss. Microscopic tissue damage in bone is most commonly measured in two-dimensional sections using stereology techniques. Stereology techniques are accurate but can have limited precision. Previous studies have presented guidelines for adequate sampling of naturally occurring microcracks in cortical bone, but such guidelines have not been presented for cancellous bone and have not addressed other forms of microscopic tissue damage (i.e. diffuse damage). Here a statistical model is presented that can be used to design studies in which microscopic tissue damage in cancellous bone is a key study outcome.","abstract_html":"Microscopic tissue damage can occur in bone as a result of an isolated overload leading to reduces bone strength under subsequent loads. In addition, microscopic tissue damage is believed to stimulate bone resorption and bone loss. Microscopic tissue damage in bone is most commonly measured in two-dimensional sections using stereology techniques. Stereology techniques are accurate but can have limited precision. Previous studies have presented guidelines for adequate sampling of naturally occurring microcracks in cortical bone, but such guidelines have not been presented for cancellous bone and have not addressed other forms of microscopic tissue damage (i.e. diffuse damage). Here a statistical model is presented that can be used to design studies in which microscopic tissue damage in cancellous bone is a key study outcome.","abstract_has_math":false,"creators":["Ehlert, Katherine"],"institution":"Cornell University","degree_name":"M.S., Mechanical Engineering","degree_level":"Master of Science","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Hernandez, Christopher J."],"committee_members":["Donnelly, Eve Lorraine"],"year":2013,"date_issued":"2013-08-19","date_published":"2013-08-19","updated_at":"2026-11-19T03:17:47Z","subjects":["Microdamage","Statistical simulation","Cancellous Bone"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8267313"],"render_values":[{"text":"8267313","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/34293","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/34293","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F34293","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Hernandez, Christopher J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Donnelly, Eve Lorraine"]},{"key":"dc:creator","label":"Author","values":["Ehlert, Katherine"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-16T16:42:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-20T06:01:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-08-19"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microdamage","Statistical simulation","Cancellous Bone"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8267313"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/34293"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"8e17e4bc-b9c2-438a-95af-4aefb87e0f8e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Methods Of Measuring Microscopic Tissue Damage In Cancellous Bone: Sampling And Statistical Power</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013-08-19</PublicationDate> <Authors> <Author> <DisplayName>Ehlert, Katherine</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Microdamage</Keyword> <Keyword>Statistical simulation</Keyword> <Keyword>Cancellous Bone</Keyword> <Abstract>Microscopic tissue damage can occur in bone as a result of an isolated overload leading to reduces bone strength under subsequent loads. In addition, microscopic tissue damage is believed to stimulate bone resorption and bone loss. Microscopic tissue damage in bone is most commonly measured in two-dimensional sections using stereology techniques. Stereology techniques are accurate but can have limited precision. Previous studies have presented guidelines for adequate sampling of naturally occurring microcracks in cortical bone, but such guidelines have not been presented for cancellous bone and have not addressed other forms of microscopic tissue damage (i.e. diffuse damage). Here a statistical model is presented that can be used to design studies in which microscopic tissue damage in cancellous bone is a key study outcome.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Ehlert, Katherine"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Microscopic tissue damage can occur in bone as a result of an isolated overload leading to reduces bone strength under subsequent loads. In addition, microscopic tissue damage is believed to stimulate bone resorption and bone loss. Microscopic tissue damage in bone is most commonly measured in two-dimensional sections using stereology techniques. Stereology techniques are accurate but can have limited precision. Previous studies have presented guidelines for adequate sampling of naturally occurring microcracks in cortical bone, but such guidelines have not been presented for cancellous bone and have not addressed other forms of microscopic tissue damage (i.e. diffuse damage). Here a statistical model is presented that can be used to design studies in which microscopic tissue damage in cancellous bone is a key study outcome."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Methods Of Measuring Microscopic Tissue Damage In Cancellous Bone: Sampling And Statistical Power"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"8e17e4bc-b9c2-438a-95af-4aefb87e0f8e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Methods Of Measuring Microscopic Tissue Damage In Cancellous Bone: Sampling And Statistical Power</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013-08-19</PublicationDate> <Authors> <Author> <DisplayName>Ehlert, Katherine</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Microdamage</Keyword> <Keyword>Statistical simulation</Keyword> <Keyword>Cancellous Bone</Keyword> <Abstract>Microscopic tissue damage can occur in bone as a result of an isolated overload leading to reduces bone strength under subsequent loads. In addition, microscopic tissue damage is believed to stimulate bone resorption and bone loss. Microscopic tissue damage in bone is most commonly measured in two-dimensional sections using stereology techniques. Stereology techniques are accurate but can have limited precision. Previous studies have presented guidelines for adequate sampling of naturally occurring microcracks in cortical bone, but such guidelines have not been presented for cancellous bone and have not addressed other forms of microscopic tissue damage (i.e. diffuse damage). Here a statistical model is presented that can be used to design studies in which microscopic tissue damage in cancellous bone is a key study outcome.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Ehlert, Katherine"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Hernandez, Christopher J."],"dc:contributor.committeemember":["Donnelly, Eve Lorraine"],"dc:creator":["Ehlert, Katherine"],"dc:date.accessioned":["2013-09-16T16:42:57Z"],"dc:date.available":["2018-08-20T06:01:19Z"],"dc:date.issued":["2013-08-19"],"dc:description.abstract":["Microscopic tissue damage can occur in bone as a result of an isolated overload leading to reduces bone strength under subsequent loads. In addition, microscopic tissue damage is believed to stimulate bone resorption and bone loss. Microscopic tissue damage in bone is most commonly measured in two-dimensional sections using stereology techniques. Stereology techniques are accurate but can have limited precision. Previous studies have presented guidelines for adequate sampling of naturally occurring microcracks in cortical bone, but such guidelines have not been presented for cancellous bone and have not addressed other forms of microscopic tissue damage (i.e. diffuse damage). Here a statistical model is presented that can be used to design studies in which microscopic tissue damage in cancellous bone is a key study outcome."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8267313"],"dc:identifier.uri":["https://hdl.handle.net/1813/34293"],"dc:language.iso":["en_US"],"dc:subject":["Microdamage","Statistical simulation","Cancellous Bone"],"dc:title":["Methods Of Measuring Microscopic Tissue Damage In Cancellous Bone: Sampling And Statistical Power"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:17:47Z"}