{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/36038"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/36038","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Transport Of Passive And Active Scalars In Microfluidics: Device Design For Solute Delivery To Rat Hippocampal Neurons, Improved Analytical Expressions For Electrokinetic Transport In Porous And Charged Layers, And Electrokinetic Interrogation Of Perfluorinated Ionomeric (Nafion) Thin Films","abstract":"First, we outline the design, modeling, and fabrication of a glass-polymer microdevice for the spatio-temporal delivery of neutral solutes to coherently grown rat hippocamapal neurons. In the design and modeling of this device, we incorporate biological constraints of the neurons and relate them to engineering parameters like solute delivery/clearing time and the fluid shear incumbent on the neurons. Next, we describe the effects of porous and charged interfaces on transport in microdevices. Porous and charged interfaces exhibit a fixed charge in a region of increased mechanical resistance. I will present approximate analytical relations to describe forces (gradients of pressure and electrical potential) and fluxes (mass and current) in a microfluidic device coated with porous and charged layers. These relations improve upon existing expressions in the literature. We demonstrate the efficacy of our results by comparison with numerical values. Finally, we execute streaming potential, conductivity, and other measurements on Nafion polymer films in a parallel-plate cell. I show that the charging of Nafion is relatively independent of pH, but that electrokinetic outputs are strongly dependent on the ionic strength of solution. These results are interpreted using our approximate analytical expressions predicting forces and fluxes.","abstract_html":"First, we outline the design, modeling, and fabrication of a glass-polymer microdevice for the spatio-temporal delivery of neutral solutes to coherently grown rat hippocamapal neurons. In the design and modeling of this device, we incorporate biological constraints of the neurons and relate them to engineering parameters like solute delivery/clearing time and the fluid shear incumbent on the neurons. Next, we describe the effects of porous and charged interfaces on transport in microdevices. Porous and charged interfaces exhibit a fixed charge in a region of increased mechanical resistance. I will present approximate analytical relations to describe forces (gradients of pressure and electrical potential) and fluxes (mass and current) in a microfluidic device coated with porous and charged layers. These relations improve upon existing expressions in the literature. We demonstrate the efficacy of our results by comparison with numerical values. Finally, we execute streaming potential, conductivity, and other measurements on Nafion polymer films in a parallel-plate cell. I show that the charging of Nafion is relatively independent of pH, but that electrokinetic outputs are strongly dependent on the ionic strength of solution. These results are interpreted using our approximate analytical expressions predicting forces and fluxes.","abstract_has_math":false,"creators":["Barbati, Alexander"],"institution":"Cornell University","degree_name":"Ph. D., Mechanical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kirby, Brian"],"committee_members":["Abruna, Hector D","Koch, Donald L"],"year":2014,"date_issued":"2014-01-27","date_published":"2014-01-27","updated_at":"2026-11-19T03:17:47Z","subjects":["microfluidics","electrokinetics","fluid mechanics"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8442195"],"render_values":[{"text":"8442195","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/36038","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/36038","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F36038","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Kirby, Brian"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Abruna, Hector D","Koch, Donald L"]},{"key":"dc:creator","label":"Author","values":["Barbati, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-02-25T18:39:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-28T07:01:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-01-27"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microfluidics","electrokinetics","fluid mechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8442195"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/36038"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"aa408422-11d4-4536-8cd0-83ae97011285\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Transport Of Passive And Active Scalars In Microfluidics: Device Design For Solute Delivery To Rat Hippocampal Neurons, Improved Analytical Expressions For Electrokinetic Transport In Porous And Charged Layers, And Electrokinetic Interrogation Of Perfluorinated Ionomeric (Nafion) Thin Films</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-01-27</PublicationDate> <Authors> <Author> <DisplayName>Barbati, Alexander</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfluidics</Keyword> <Keyword>electrokinetics</Keyword> <Keyword>fluid mechanics</Keyword> <Abstract>First, we outline the design, modeling, and fabrication of a glass-polymer microdevice for the spatio-temporal delivery of neutral solutes to coherently grown rat hippocamapal neurons. In the design and modeling of this device, we incorporate biological constraints of the neurons and relate them to engineering parameters like solute delivery/clearing time and the fluid shear incumbent on the neurons. Next, we describe the effects of porous and charged interfaces on transport in microdevices. Porous and charged interfaces exhibit a fixed charge in a region of increased mechanical resistance. I will present approximate analytical relations to describe forces (gradients of pressure and electrical potential) and fluxes (mass and current) in a microfluidic device coated with porous and charged layers. These relations improve upon existing expressions in the literature. We demonstrate the efficacy of our results by comparison with numerical values. Finally, we execute streaming potential, conductivity, and other measurements on Nafion polymer films in a parallel-plate cell. I show that the charging of Nafion is relatively independent of pH, but that electrokinetic outputs are strongly dependent on the ionic strength of solution. These results are interpreted using our approximate analytical expressions predicting forces and fluxes.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Barbati, Alexander"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["First, we outline the design, modeling, and fabrication of a glass-polymer microdevice for the spatio-temporal delivery of neutral solutes to coherently grown rat hippocamapal neurons. In the design and modeling of this device, we incorporate biological constraints of the neurons and relate them to engineering parameters like solute delivery/clearing time and the fluid shear incumbent on the neurons. Next, we describe the effects of porous and charged interfaces on transport in microdevices. Porous and charged interfaces exhibit a fixed charge in a region of increased mechanical resistance. I will present approximate analytical relations to describe forces (gradients of pressure and electrical potential) and fluxes (mass and current) in a microfluidic device coated with porous and charged layers. These relations improve upon existing expressions in the literature. We demonstrate the efficacy of our results by comparison with numerical values. Finally, we execute streaming potential, conductivity, and other measurements on Nafion polymer films in a parallel-plate cell. I show that the charging of Nafion is relatively independent of pH, but that electrokinetic outputs are strongly dependent on the ionic strength of solution. These results are interpreted using our approximate analytical expressions predicting forces and fluxes."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Transport Of Passive And Active Scalars In Microfluidics: Device Design For Solute Delivery To Rat Hippocampal Neurons, Improved Analytical Expressions For Electrokinetic Transport In Porous And Charged Layers, And Electrokinetic Interrogation Of Perfluorinated Ionomeric (Nafion) Thin Films"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"aa408422-11d4-4536-8cd0-83ae97011285\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Transport Of Passive And Active Scalars In Microfluidics: Device Design For Solute Delivery To Rat Hippocampal Neurons, Improved Analytical Expressions For Electrokinetic Transport In Porous And Charged Layers, And Electrokinetic Interrogation Of Perfluorinated Ionomeric (Nafion) Thin Films</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-01-27</PublicationDate> <Authors> <Author> <DisplayName>Barbati, Alexander</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfluidics</Keyword> <Keyword>electrokinetics</Keyword> <Keyword>fluid mechanics</Keyword> <Abstract>First, we outline the design, modeling, and fabrication of a glass-polymer microdevice for the spatio-temporal delivery of neutral solutes to coherently grown rat hippocamapal neurons. In the design and modeling of this device, we incorporate biological constraints of the neurons and relate them to engineering parameters like solute delivery/clearing time and the fluid shear incumbent on the neurons. Next, we describe the effects of porous and charged interfaces on transport in microdevices. Porous and charged interfaces exhibit a fixed charge in a region of increased mechanical resistance. I will present approximate analytical relations to describe forces (gradients of pressure and electrical potential) and fluxes (mass and current) in a microfluidic device coated with porous and charged layers. These relations improve upon existing expressions in the literature. We demonstrate the efficacy of our results by comparison with numerical values. Finally, we execute streaming potential, conductivity, and other measurements on Nafion polymer films in a parallel-plate cell. I show that the charging of Nafion is relatively independent of pH, but that electrokinetic outputs are strongly dependent on the ionic strength of solution. These results are interpreted using our approximate analytical expressions predicting forces and fluxes.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Barbati, Alexander"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Kirby, Brian"],"dc:contributor.committeemember":["Abruna, Hector D","Koch, Donald L"],"dc:creator":["Barbati, Alexander"],"dc:date.accessioned":["2014-02-25T18:39:56Z"],"dc:date.available":["2019-01-28T07:01:52Z"],"dc:date.issued":["2014-01-27"],"dc:description.abstract":["First, we outline the design, modeling, and fabrication of a glass-polymer microdevice for the spatio-temporal delivery of neutral solutes to coherently grown rat hippocamapal neurons. In the design and modeling of this device, we incorporate biological constraints of the neurons and relate them to engineering parameters like solute delivery/clearing time and the fluid shear incumbent on the neurons. Next, we describe the effects of porous and charged interfaces on transport in microdevices. Porous and charged interfaces exhibit a fixed charge in a region of increased mechanical resistance. I will present approximate analytical relations to describe forces (gradients of pressure and electrical potential) and fluxes (mass and current) in a microfluidic device coated with porous and charged layers. These relations improve upon existing expressions in the literature. We demonstrate the efficacy of our results by comparison with numerical values. Finally, we execute streaming potential, conductivity, and other measurements on Nafion polymer films in a parallel-plate cell. I show that the charging of Nafion is relatively independent of pH, but that electrokinetic outputs are strongly dependent on the ionic strength of solution. These results are interpreted using our approximate analytical expressions predicting forces and fluxes."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8442195"],"dc:identifier.uri":["https://hdl.handle.net/1813/36038"],"dc:language.iso":["en_US"],"dc:subject":["microfluidics","electrokinetics","fluid mechanics"],"dc:title":["Transport Of Passive And Active Scalars In Microfluidics: Device Design For Solute Delivery To Rat Hippocampal Neurons, Improved Analytical Expressions For Electrokinetic Transport In Porous And Charged Layers, And Electrokinetic Interrogation Of Perfluorinated Ionomeric (Nafion) Thin Films"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:17:47Z"}