{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/38764"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/38764","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Stability Of Growth Factors In Platelet Rich Plasma","abstract":"The use of platelet rich plasma (PRP) in sports medicine has increased dramatically recently but there are still doubts towards its efficacy that likely stem from the wide variety between PRP samples and products. To further define PRP, this study aimed to test whether its composition was altered if PRP or the blood used to produce PRP, remained out at room temperature before use. Another aim was to establish if a manual platelet count would adequately quantify platelet concentration compared to using automated methods. All types of PRP product tested remained stable, according to growth factor and cytokine measurements, for up to four hours when stored at room temperature. No significant differences were found in platelet concentrations obtained from automated or manual methods. The results found confirm the ease of verifying platelet concentration manually and that PRP can be used in orthopedic and surgical situations without worry of product degradation.","abstract_html":"The use of platelet rich plasma (PRP) in sports medicine has increased dramatically recently but there are still doubts towards its efficacy that likely stem from the wide variety between PRP samples and products. To further define PRP, this study aimed to test whether its composition was altered if PRP or the blood used to produce PRP, remained out at room temperature before use. Another aim was to establish if a manual platelet count would adequately quantify platelet concentration compared to using automated methods. All types of PRP product tested remained stable, according to growth factor and cytokine measurements, for up to four hours when stored at room temperature. No significant differences were found in platelet concentrations obtained from automated or manual methods. The results found confirm the ease of verifying platelet concentration manually and that PRP can be used in orthopedic and surgical situations without worry of product degradation.","abstract_has_math":false,"creators":["Wilson, Brooke"],"institution":"Cornell University","degree_name":"M.S., Veterinary Medicine","degree_level":"Master of Science","degree_discipline":"Veterinary Medicine","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Fortier, Lisa Ann"],"committee_members":["Mohammed, Hussni Omar"],"year":2014,"date_issued":"2014-08-18","date_published":"2014-08-18","updated_at":"2026-11-19T03:18:04Z","subjects":["platelet rich plasma (PRP)","regenerative medicine","growth factors"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793254"],"render_values":[{"text":"8793254","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/38764","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/38764","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F38764","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Fortier, Lisa Ann"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mohammed, Hussni Omar"]},{"key":"dc:creator","label":"Author","values":["Wilson, Brooke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-07T20:57:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-19T06:01:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-08-18"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Veterinary Medicine"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Veterinary Medicine"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["platelet rich plasma (PRP)","regenerative medicine","growth factors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793254"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/38764"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9d1c0e1f-76f8-4030-b5f0-e40f7664934a\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Stability Of Growth Factors In Platelet Rich Plasma</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Wilson, Brooke</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>platelet rich plasma (PRP)</Keyword> <Keyword>regenerative medicine</Keyword> <Keyword>growth factors</Keyword> <Abstract>The use of platelet rich plasma (PRP) in sports medicine has increased dramatically recently but there are still doubts towards its efficacy that likely stem from the wide variety between PRP samples and products. To further define PRP, this study aimed to test whether its composition was altered if PRP or the blood used to produce PRP, remained out at room temperature before use. Another aim was to establish if a manual platelet count would adequately quantify platelet concentration compared to using automated methods. All types of PRP product tested remained stable, according to growth factor and cytokine measurements, for up to four hours when stored at room temperature. No significant differences were found in platelet concentrations obtained from automated or manual methods. The results found confirm the ease of verifying platelet concentration manually and that PRP can be used in orthopedic and surgical situations without worry of product degradation.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Wilson, Brooke"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["The use of platelet rich plasma (PRP) in sports medicine has increased dramatically recently but there are still doubts towards its efficacy that likely stem from the wide variety between PRP samples and products. To further define PRP, this study aimed to test whether its composition was altered if PRP or the blood used to produce PRP, remained out at room temperature before use. Another aim was to establish if a manual platelet count would adequately quantify platelet concentration compared to using automated methods. All types of PRP product tested remained stable, according to growth factor and cytokine measurements, for up to four hours when stored at room temperature. No significant differences were found in platelet concentrations obtained from automated or manual methods. The results found confirm the ease of verifying platelet concentration manually and that PRP can be used in orthopedic and surgical situations without worry of product degradation."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Stability Of Growth Factors In Platelet Rich Plasma"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9d1c0e1f-76f8-4030-b5f0-e40f7664934a\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Stability Of Growth Factors In Platelet Rich Plasma</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Wilson, Brooke</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>platelet rich plasma (PRP)</Keyword> <Keyword>regenerative medicine</Keyword> <Keyword>growth factors</Keyword> <Abstract>The use of platelet rich plasma (PRP) in sports medicine has increased dramatically recently but there are still doubts towards its efficacy that likely stem from the wide variety between PRP samples and products. To further define PRP, this study aimed to test whether its composition was altered if PRP or the blood used to produce PRP, remained out at room temperature before use. Another aim was to establish if a manual platelet count would adequately quantify platelet concentration compared to using automated methods. All types of PRP product tested remained stable, according to growth factor and cytokine measurements, for up to four hours when stored at room temperature. No significant differences were found in platelet concentrations obtained from automated or manual methods. The results found confirm the ease of verifying platelet concentration manually and that PRP can be used in orthopedic and surgical situations without worry of product degradation.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Wilson, Brooke"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Fortier, Lisa Ann"],"dc:contributor.committeemember":["Mohammed, Hussni Omar"],"dc:creator":["Wilson, Brooke"],"dc:date.accessioned":["2015-01-07T20:57:00Z"],"dc:date.available":["2019-08-19T06:01:29Z"],"dc:date.issued":["2014-08-18"],"dc:description.abstract":["The use of platelet rich plasma (PRP) in sports medicine has increased dramatically recently but there are still doubts towards its efficacy that likely stem from the wide variety between PRP samples and products. To further define PRP, this study aimed to test whether its composition was altered if PRP or the blood used to produce PRP, remained out at room temperature before use. Another aim was to establish if a manual platelet count would adequately quantify platelet concentration compared to using automated methods. All types of PRP product tested remained stable, according to growth factor and cytokine measurements, for up to four hours when stored at room temperature. No significant differences were found in platelet concentrations obtained from automated or manual methods. The results found confirm the ease of verifying platelet concentration manually and that PRP can be used in orthopedic and surgical situations without worry of product degradation."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8793254"],"dc:identifier.uri":["https://hdl.handle.net/1813/38764"],"dc:language.iso":["en_US"],"dc:subject":["platelet rich plasma (PRP)","regenerative medicine","growth factors"],"dc:title":["Stability Of Growth Factors In Platelet Rich Plasma"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Veterinary Medicine"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Veterinary Medicine"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:04Z"}