{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/38778"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/38778","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry","abstract":"Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan- dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization.","abstract_html":"Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan- dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization.","abstract_has_math":false,"creators":["Dorta Quinones, Carlos"],"institution":"Cornell University","degree_name":"Ph. D., Electrical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Apsel, Alyssa B."],"committee_members":["Molnar, Alyosha Christopher","Lindau, Manfred"],"year":2014,"date_issued":"2014-08-18","date_published":"2014-08-18","updated_at":"2026-11-19T03:18:04Z","subjects":["neurochemical monitoring","fast-scan cyclic voltammetry","dopamine detection"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793274"],"render_values":[{"text":"8793274","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/38778","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/38778","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F38778","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Apsel, Alyssa B."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Molnar, Alyosha Christopher","Lindau, Manfred"]},{"key":"dc:creator","label":"Author","values":["Dorta Quinones, Carlos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-07T20:57:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-19T06:01:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-08-18"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["neurochemical monitoring","fast-scan cyclic voltammetry","dopamine detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793274"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/38778"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"54ff920c-b180-456e-bd95-48f3fda35269\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Dorta Quinones, Carlos</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>neurochemical monitoring</Keyword> <Keyword>fast-scan cyclic voltammetry</Keyword> <Keyword>dopamine detection</Keyword> <Abstract>Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan- dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Dorta Quinones, Carlos"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan- dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"54ff920c-b180-456e-bd95-48f3fda35269\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Dorta Quinones, Carlos</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>neurochemical monitoring</Keyword> <Keyword>fast-scan cyclic voltammetry</Keyword> <Keyword>dopamine detection</Keyword> <Abstract>Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan- dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Dorta Quinones, Carlos"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Apsel, Alyssa B."],"dc:contributor.committeemember":["Molnar, Alyosha Christopher","Lindau, Manfred"],"dc:creator":["Dorta Quinones, Carlos"],"dc:date.accessioned":["2015-01-07T20:57:07Z"],"dc:date.available":["2019-08-19T06:01:03Z"],"dc:date.issued":["2014-08-18"],"dc:description.abstract":["Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan- dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8793274"],"dc:identifier.uri":["https://hdl.handle.net/1813/38778"],"dc:language.iso":["en_US"],"dc:subject":["neurochemical monitoring","fast-scan cyclic voltammetry","dopamine detection"],"dc:title":["Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Electrical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:04Z"}