{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/38976"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/38976","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Characterization Of Microfluidic Shear-Dependent Immunocapture And Enrichment Of Cancer Cells From Blood Cells With Dielectrophoresis","abstract":"In this work, we investigate the effects of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells' DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with interdigitated electrodes. At the same applied electric field frequency, we demonstrate enhanced capture of cancer cells by attracting them to immunocapture surfaces with positive DEP and reduced nonspecific adhesion of peripheral blood mononuclear cells (PBMCs) by repelling them from immunocapture surfaces with negative DEP. Using an exponential capture model, we show that immunocapture performance is dependent on the applied DEP force sign and magnitude, cell and immunocapture surface chemistry, and shear stress experienced by cells flowing in the capture device. These data inform the simulation of cancer cell and blood cell capture probabilities to design future hybrid DEP and immunocapture device geometries with improved rare cell capture performance.","abstract_html":"In this work, we investigate the effects of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells&#x27; DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with interdigitated electrodes. At the same applied electric field frequency, we demonstrate enhanced capture of cancer cells by attracting them to immunocapture surfaces with positive DEP and reduced nonspecific adhesion of peripheral blood mononuclear cells (PBMCs) by repelling them from immunocapture surfaces with negative DEP. Using an exponential capture model, we show that immunocapture performance is dependent on the applied DEP force sign and magnitude, cell and immunocapture surface chemistry, and shear stress experienced by cells flowing in the capture device. These data inform the simulation of cancer cell and blood cell capture probabilities to design future hybrid DEP and immunocapture device geometries with improved rare cell capture performance.","abstract_has_math":false,"creators":["Huang, Chao"],"institution":"Cornell University","degree_name":"Ph. D., Biomedical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kirby, Brian"],"committee_members":["Weiss, Robert S.","Daniel, Susan"],"year":2014,"date_issued":"2014-08-18","date_published":"2014-08-18","updated_at":"2026-11-19T03:18:04Z","subjects":["Dielectrophoresis","Microfluidics","Cancer"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793272"],"render_values":[{"text":"8793272","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/38976","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/38976","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F38976","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Kirby, Brian"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Weiss, Robert S.","Daniel, Susan"]},{"key":"dc:creator","label":"Author","values":["Huang, Chao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-07T20:58:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-07T20:58:47Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-08-18"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Biomedical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dielectrophoresis","Microfluidics","Cancer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793272"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/38976"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9156b5c6-766c-42c9-9d56-679af6a7f596\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Characterization Of Microfluidic Shear-Dependent Immunocapture And Enrichment Of Cancer Cells From Blood Cells With Dielectrophoresis</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Huang, Chao</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Dielectrophoresis</Keyword> <Keyword>Microfluidics</Keyword> <Keyword>Cancer</Keyword> <Abstract>In this work, we investigate the effects of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells' DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with interdigitated electrodes. At the same applied electric field frequency, we demonstrate enhanced capture of cancer cells by attracting them to immunocapture surfaces with positive DEP and reduced nonspecific adhesion of peripheral blood mononuclear cells (PBMCs) by repelling them from immunocapture surfaces with negative DEP. Using an exponential capture model, we show that immunocapture performance is dependent on the applied DEP force sign and magnitude, cell and immunocapture surface chemistry, and shear stress experienced by cells flowing in the capture device. These data inform the simulation of cancer cell and blood cell capture probabilities to design future hybrid DEP and immunocapture device geometries with improved rare cell capture performance.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Huang, Chao"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["In this work, we investigate the effects of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells' DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with interdigitated electrodes. At the same applied electric field frequency, we demonstrate enhanced capture of cancer cells by attracting them to immunocapture surfaces with positive DEP and reduced nonspecific adhesion of peripheral blood mononuclear cells (PBMCs) by repelling them from immunocapture surfaces with negative DEP. Using an exponential capture model, we show that immunocapture performance is dependent on the applied DEP force sign and magnitude, cell and immunocapture surface chemistry, and shear stress experienced by cells flowing in the capture device. These data inform the simulation of cancer cell and blood cell capture probabilities to design future hybrid DEP and immunocapture device geometries with improved rare cell capture performance."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization Of Microfluidic Shear-Dependent Immunocapture And Enrichment Of Cancer Cells From Blood Cells With Dielectrophoresis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9156b5c6-766c-42c9-9d56-679af6a7f596\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Characterization Of Microfluidic Shear-Dependent Immunocapture And Enrichment Of Cancer Cells From Blood Cells With Dielectrophoresis</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Huang, Chao</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Dielectrophoresis</Keyword> <Keyword>Microfluidics</Keyword> <Keyword>Cancer</Keyword> <Abstract>In this work, we investigate the effects of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells' DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with interdigitated electrodes. At the same applied electric field frequency, we demonstrate enhanced capture of cancer cells by attracting them to immunocapture surfaces with positive DEP and reduced nonspecific adhesion of peripheral blood mononuclear cells (PBMCs) by repelling them from immunocapture surfaces with negative DEP. Using an exponential capture model, we show that immunocapture performance is dependent on the applied DEP force sign and magnitude, cell and immunocapture surface chemistry, and shear stress experienced by cells flowing in the capture device. These data inform the simulation of cancer cell and blood cell capture probabilities to design future hybrid DEP and immunocapture device geometries with improved rare cell capture performance.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Huang, Chao"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Kirby, Brian"],"dc:contributor.committeemember":["Weiss, Robert S.","Daniel, Susan"],"dc:creator":["Huang, Chao"],"dc:date.accessioned":["2015-01-07T20:58:47Z"],"dc:date.available":["2015-01-07T20:58:47Z"],"dc:date.issued":["2014-08-18"],"dc:description.abstract":["In this work, we investigate the effects of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells' DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with interdigitated electrodes. At the same applied electric field frequency, we demonstrate enhanced capture of cancer cells by attracting them to immunocapture surfaces with positive DEP and reduced nonspecific adhesion of peripheral blood mononuclear cells (PBMCs) by repelling them from immunocapture surfaces with negative DEP. Using an exponential capture model, we show that immunocapture performance is dependent on the applied DEP force sign and magnitude, cell and immunocapture surface chemistry, and shear stress experienced by cells flowing in the capture device. These data inform the simulation of cancer cell and blood cell capture probabilities to design future hybrid DEP and immunocapture device geometries with improved rare cell capture performance."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8793272"],"dc:identifier.uri":["https://hdl.handle.net/1813/38976"],"dc:language.iso":["en_US"],"dc:subject":["Dielectrophoresis","Microfluidics","Cancer"],"dc:title":["Characterization Of Microfluidic Shear-Dependent Immunocapture And Enrichment Of Cancer Cells From Blood Cells With Dielectrophoresis"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Biomedical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:04Z"}