{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/38997"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/38997","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Reconstructing Images From Sparse Data","abstract":"In this dissertation, the process of recovering structure from sparse data is discussed. Specifically, studies are undertaken for the case of X-ray imaging with weak signal. The limit of interest is when each image (or data frame) is so sparsely populated with X-ray photons that the structure of the object is not discernable. These techniques will be required to perform single molecule imaging using X-ray free electron lasers and serial microcrystallography experiments at synchrotron sources. An overview of the problem and the reconstruction algorithm is given in Chapter 1. In Chapters 2, 3 and 4, three different experiments are discussed, each with a different imaging geometry. All three experiments have the same property in that there are many data frames all of whom are very sparsely occupied. In Chapter 2, a shadowgraphy experiment is performed with a randomly rotated mask whose projected shadow on the detector is reconstructed from a large number of images with a signal level as low as 2.5 photons per data frame. In Chapter 3, using a computed tomography (CT) setup with unrecorded orientations, the 3D structure of a plastic figure is reconstructed. And finally, in Chapter 4, a weak beam is used to illuminate a crystal and the sparse diffraction pattern is measured. The successful reconstruction of the 3D intensity distribution shows promise for the possibility of serial microcrystallography [5] at conventional syn- chrotron sources. Appendix A contains a more detailed discussion of the reconstruction process for the crystallography experiment in Chapter 4. This record is made to enable other parties to reproduce the results as well as to document the intuition used in choosing various reconstruction parameters.","abstract_html":"In this dissertation, the process of recovering structure from sparse data is discussed. Specifically, studies are undertaken for the case of X-ray imaging with weak signal. The limit of interest is when each image (or data frame) is so sparsely populated with X-ray photons that the structure of the object is not discernable. These techniques will be required to perform single molecule imaging using X-ray free electron lasers and serial microcrystallography experiments at synchrotron sources. An overview of the problem and the reconstruction algorithm is given in Chapter 1. In Chapters 2, 3 and 4, three different experiments are discussed, each with a different imaging geometry. All three experiments have the same property in that there are many data frames all of whom are very sparsely occupied. In Chapter 2, a shadowgraphy experiment is performed with a randomly rotated mask whose projected shadow on the detector is reconstructed from a large number of images with a signal level as low as 2.5 photons per data frame. In Chapter 3, using a computed tomography (CT) setup with unrecorded orientations, the 3D structure of a plastic figure is reconstructed. And finally, in Chapter 4, a weak beam is used to illuminate a crystal and the sparse diffraction pattern is measured. The successful reconstruction of the 3D intensity distribution shows promise for the possibility of serial microcrystallography [5] at conventional syn- chrotron sources. Appendix A contains a more detailed discussion of the reconstruction process for the crystallography experiment in Chapter 4. This record is made to enable other parties to reproduce the results as well as to document the intuition used in choosing various reconstruction parameters.","abstract_has_math":false,"creators":["Ayyer, Kartik"],"institution":"Cornell University","degree_name":"Ph. D., Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Elser, Veit"],"committee_members":["Myers, Christopher R","Gruner, Sol Michael"],"year":2014,"date_issued":"2014-08-18","date_published":"2014-08-18","updated_at":"2026-11-19T03:18:04Z","subjects":["X-ray imaging"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793379"],"render_values":[{"text":"8793379","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/38997","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/38997","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F38997","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Elser, Veit"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Myers, Christopher R","Gruner, Sol Michael"]},{"key":"dc:creator","label":"Author","values":["Ayyer, Kartik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-07T20:58:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-07T20:58:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-08-18"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["X-ray imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["8793379"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/38997"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a4a42fa3-a2c2-4e3d-a0ba-a6349aed3d69\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Reconstructing Images From Sparse Data</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Ayyer, Kartik</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>X-ray imaging</Keyword> <Abstract>In this dissertation, the process of recovering structure from sparse data is discussed. Specifically, studies are undertaken for the case of X-ray imaging with weak signal. The limit of interest is when each image (or data frame) is so sparsely populated with X-ray photons that the structure of the object is not discernable. These techniques will be required to perform single molecule imaging using X-ray free electron lasers and serial microcrystallography experiments at synchrotron sources. An overview of the problem and the reconstruction algorithm is given in Chapter 1. In Chapters 2, 3 and 4, three different experiments are discussed, each with a different imaging geometry. All three experiments have the same property in that there are many data frames all of whom are very sparsely occupied. In Chapter 2, a shadowgraphy experiment is performed with a randomly rotated mask whose projected shadow on the detector is reconstructed from a large number of images with a signal level as low as 2.5 photons per data frame. In Chapter 3, using a computed tomography (CT) setup with unrecorded orientations, the 3D structure of a plastic figure is reconstructed. And finally, in Chapter 4, a weak beam is used to illuminate a crystal and the sparse diffraction pattern is measured. The successful reconstruction of the 3D intensity distribution shows promise for the possibility of serial microcrystallography [5] at conventional syn- chrotron sources. Appendix A contains a more detailed discussion of the reconstruction process for the crystallography experiment in Chapter 4. This record is made to enable other parties to reproduce the results as well as to document the intuition used in choosing various reconstruction parameters.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Ayyer, Kartik"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["In this dissertation, the process of recovering structure from sparse data is discussed. Specifically, studies are undertaken for the case of X-ray imaging with weak signal. The limit of interest is when each image (or data frame) is so sparsely populated with X-ray photons that the structure of the object is not discernable. These techniques will be required to perform single molecule imaging using X-ray free electron lasers and serial microcrystallography experiments at synchrotron sources. An overview of the problem and the reconstruction algorithm is given in Chapter 1. In Chapters 2, 3 and 4, three different experiments are discussed, each with a different imaging geometry. All three experiments have the same property in that there are many data frames all of whom are very sparsely occupied. In Chapter 2, a shadowgraphy experiment is performed with a randomly rotated mask whose projected shadow on the detector is reconstructed from a large number of images with a signal level as low as 2.5 photons per data frame. In Chapter 3, using a computed tomography (CT) setup with unrecorded orientations, the 3D structure of a plastic figure is reconstructed. And finally, in Chapter 4, a weak beam is used to illuminate a crystal and the sparse diffraction pattern is measured. The successful reconstruction of the 3D intensity distribution shows promise for the possibility of serial microcrystallography [5] at conventional syn- chrotron sources. Appendix A contains a more detailed discussion of the reconstruction process for the crystallography experiment in Chapter 4. This record is made to enable other parties to reproduce the results as well as to document the intuition used in choosing various reconstruction parameters."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Reconstructing Images From Sparse Data"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a4a42fa3-a2c2-4e3d-a0ba-a6349aed3d69\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Reconstructing Images From Sparse Data</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014-08-18</PublicationDate> <Authors> <Author> <DisplayName>Ayyer, Kartik</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>X-ray imaging</Keyword> <Abstract>In this dissertation, the process of recovering structure from sparse data is discussed. Specifically, studies are undertaken for the case of X-ray imaging with weak signal. The limit of interest is when each image (or data frame) is so sparsely populated with X-ray photons that the structure of the object is not discernable. These techniques will be required to perform single molecule imaging using X-ray free electron lasers and serial microcrystallography experiments at synchrotron sources. An overview of the problem and the reconstruction algorithm is given in Chapter 1. In Chapters 2, 3 and 4, three different experiments are discussed, each with a different imaging geometry. All three experiments have the same property in that there are many data frames all of whom are very sparsely occupied. In Chapter 2, a shadowgraphy experiment is performed with a randomly rotated mask whose projected shadow on the detector is reconstructed from a large number of images with a signal level as low as 2.5 photons per data frame. In Chapter 3, using a computed tomography (CT) setup with unrecorded orientations, the 3D structure of a plastic figure is reconstructed. And finally, in Chapter 4, a weak beam is used to illuminate a crystal and the sparse diffraction pattern is measured. The successful reconstruction of the 3D intensity distribution shows promise for the possibility of serial microcrystallography [5] at conventional syn- chrotron sources. Appendix A contains a more detailed discussion of the reconstruction process for the crystallography experiment in Chapter 4. This record is made to enable other parties to reproduce the results as well as to document the intuition used in choosing various reconstruction parameters.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Ayyer, Kartik"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Elser, Veit"],"dc:contributor.committeemember":["Myers, Christopher R","Gruner, Sol Michael"],"dc:creator":["Ayyer, Kartik"],"dc:date.accessioned":["2015-01-07T20:58:57Z"],"dc:date.available":["2015-01-07T20:58:57Z"],"dc:date.issued":["2014-08-18"],"dc:description.abstract":["In this dissertation, the process of recovering structure from sparse data is discussed. Specifically, studies are undertaken for the case of X-ray imaging with weak signal. The limit of interest is when each image (or data frame) is so sparsely populated with X-ray photons that the structure of the object is not discernable. These techniques will be required to perform single molecule imaging using X-ray free electron lasers and serial microcrystallography experiments at synchrotron sources. An overview of the problem and the reconstruction algorithm is given in Chapter 1. In Chapters 2, 3 and 4, three different experiments are discussed, each with a different imaging geometry. All three experiments have the same property in that there are many data frames all of whom are very sparsely occupied. In Chapter 2, a shadowgraphy experiment is performed with a randomly rotated mask whose projected shadow on the detector is reconstructed from a large number of images with a signal level as low as 2.5 photons per data frame. In Chapter 3, using a computed tomography (CT) setup with unrecorded orientations, the 3D structure of a plastic figure is reconstructed. And finally, in Chapter 4, a weak beam is used to illuminate a crystal and the sparse diffraction pattern is measured. The successful reconstruction of the 3D intensity distribution shows promise for the possibility of serial microcrystallography [5] at conventional syn- chrotron sources. Appendix A contains a more detailed discussion of the reconstruction process for the crystallography experiment in Chapter 4. This record is made to enable other parties to reproduce the results as well as to document the intuition used in choosing various reconstruction parameters."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["8793379"],"dc:identifier.uri":["https://hdl.handle.net/1813/38997"],"dc:language.iso":["en_US"],"dc:subject":["X-ray imaging"],"dc:title":["Reconstructing Images From Sparse Data"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:04Z"}