{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/39303"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/39303","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Parallel Acquisition In Multiphoton Microscopy: Temporal Focusing And Frequency Multiplexing","abstract":"Multiphoton microscopy is a powerful platform for both biological study and medical imaging. Techniques developed on this platform have achieved unparalleled resolution and chemical specificity, imaging at depths unreachable by traditional forms of optical microscopy. This thesis details several techniques meant to improve multiphoton depth penetration, imaging speed, and medical applicability. One such technique uses a modified form of simultaneous spatial and temporal focusing (SSTF) to achieve enhanced axial confinement. In SSTF a diffraction grating is imaged onto the sample, and the separation and recombination of the excitation spectral components form a temporal focus. By blocking the central portion of the excitation spectrum, an effective two-color two-photon imaging system is formed. By detecting only the resulting sum frequency generation signal the axial confinement becomes significantly tighter than that achieved by conventional two-photon microscopy. The temporal focus of SSTF may be axially scanned by modulating the group delay dispersion (GDD) of the excitation pulse. In a proof-of-concept experiment, a piezo-bimorph mirror is used to rapidly modulate GDD in a temporal focusing setup. Axial scans over 60 [mu]m of mouse skin are performed at speeds up to 200Hz. This is done through an optical fiber and with no moving parts or electrical components at the distal end, paving the way for the development of a minimally invasive, axial scanning endoscope. Another technique uses frequency multiplexing to perform parallel acquisition of image data using a single-element detector. Five hundred pixels in a line are individually intensity modulated at different radio frequencies. A Fourier transform of the signal unscrambles the image data after detection. In scattering regimes where conventional parallel acquisition (i.e. charge coupled device array, or CCD) methods are impossible, this multifocal multiphoton modulation microscopy (M4) technique allows for higher signal-to-noise ratios and faster imaging. Fluorescent/phosphorescent lifetime can be calculated from the phase component of the Fourier transform in the M4 technique. In combination with the inherent speed advantages of M4, this is used to take full-frame phosphorescent lifetime images of oxygen-sensing dye in vivo in mouse brain vasculature at record speed. ii","abstract_html":"Multiphoton microscopy is a powerful platform for both biological study and medical imaging. Techniques developed on this platform have achieved unparalleled resolution and chemical specificity, imaging at depths unreachable by traditional forms of optical microscopy. This thesis details several techniques meant to improve multiphoton depth penetration, imaging speed, and medical applicability. One such technique uses a modified form of simultaneous spatial and temporal focusing (SSTF) to achieve enhanced axial confinement. In SSTF a diffraction grating is imaged onto the sample, and the separation and recombination of the excitation spectral components form a temporal focus. By blocking the central portion of the excitation spectrum, an effective two-color two-photon imaging system is formed. By detecting only the resulting sum frequency generation signal the axial confinement becomes significantly tighter than that achieved by conventional two-photon microscopy. The temporal focus of SSTF may be axially scanned by modulating the group delay dispersion (GDD) of the excitation pulse. In a proof-of-concept experiment, a piezo-bimorph mirror is used to rapidly modulate GDD in a temporal focusing setup. Axial scans over 60 [mu]m of mouse skin are performed at speeds up to 200Hz. This is done through an optical fiber and with no moving parts or electrical components at the distal end, paving the way for the development of a minimally invasive, axial scanning endoscope. Another technique uses frequency multiplexing to perform parallel acquisition of image data using a single-element detector. Five hundred pixels in a line are individually intensity modulated at different radio frequencies. A Fourier transform of the signal unscrambles the image data after detection. In scattering regimes where conventional parallel acquisition (i.e. charge coupled device array, or CCD) methods are impossible, this multifocal multiphoton modulation microscopy (M4) technique allows for higher signal-to-noise ratios and faster imaging. Fluorescent/phosphorescent lifetime can be calculated from the phase component of the Fourier transform in the M4 technique. In combination with the inherent speed advantages of M4, this is used to take full-frame phosphorescent lifetime images of oxygen-sensing dye in vivo in mouse brain vasculature at record speed. ii","abstract_has_math":false,"creators":["Straub, Adam"],"institution":"Cornell University","degree_name":"Ph. D., Applied Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Xu, Chunhui"],"committee_members":["Zipfel, Warren R.","Lipson, Michal"],"year":2015,"date_issued":"2015-01-26","date_published":"2015-01-26","updated_at":"2026-11-19T03:18:04Z","subjects":["Two-photon","Microscopy","Temporal Focusing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9154380"],"render_values":[{"text":"9154380","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/39303","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/39303","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F39303","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Xu, Chunhui"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zipfel, Warren R.","Lipson, Michal"]},{"key":"dc:creator","label":"Author","values":["Straub, Adam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-04-06T20:13:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-01-27T07:01:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-01-26"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Two-photon","Microscopy","Temporal Focusing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9154380"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/39303"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"97b0266a-088a-4386-8e87-fbf7d2477307\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Parallel Acquisition In Multiphoton Microscopy: Temporal Focusing And Frequency Multiplexing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015-01-26</PublicationDate> <Authors> <Author> <DisplayName>Straub, Adam</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Two-photon</Keyword> <Keyword>Microscopy</Keyword> <Keyword>Temporal Focusing</Keyword> <Abstract>Multiphoton microscopy is a powerful platform for both biological study and medical imaging. Techniques developed on this platform have achieved unparalleled resolution and chemical specificity, imaging at depths unreachable by traditional forms of optical microscopy. This thesis details several techniques meant to improve multiphoton depth penetration, imaging speed, and medical applicability. One such technique uses a modified form of simultaneous spatial and temporal focusing (SSTF) to achieve enhanced axial confinement. In SSTF a diffraction grating is imaged onto the sample, and the separation and recombination of the excitation spectral components form a temporal focus. By blocking the central portion of the excitation spectrum, an effective two-color two-photon imaging system is formed. By detecting only the resulting sum frequency generation signal the axial confinement becomes significantly tighter than that achieved by conventional two-photon microscopy. The temporal focus of SSTF may be axially scanned by modulating the group delay dispersion (GDD) of the excitation pulse. In a proof-of-concept experiment, a piezo-bimorph mirror is used to rapidly modulate GDD in a temporal focusing setup. Axial scans over 60 [mu]m of mouse skin are performed at speeds up to 200Hz. This is done through an optical fiber and with no moving parts or electrical components at the distal end, paving the way for the development of a minimally invasive, axial scanning endoscope. Another technique uses frequency multiplexing to perform parallel acquisition of image data using a single-element detector. Five hundred pixels in a line are individually intensity modulated at different radio frequencies. A Fourier transform of the signal unscrambles the image data after detection. In scattering regimes where conventional parallel acquisition (i.e. charge coupled device array, or CCD) methods are impossible, this multifocal multiphoton modulation microscopy (M4) technique allows for higher signal-to-noise ratios and faster imaging. Fluorescent/phosphorescent lifetime can be calculated from the phase component of the Fourier transform in the M4 technique. In combination with the inherent speed advantages of M4, this is used to take full-frame phosphorescent lifetime images of oxygen-sensing dye in vivo in mouse brain vasculature at record speed. ii</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Straub, Adam"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Multiphoton microscopy is a powerful platform for both biological study and medical imaging. Techniques developed on this platform have achieved unparalleled resolution and chemical specificity, imaging at depths unreachable by traditional forms of optical microscopy. This thesis details several techniques meant to improve multiphoton depth penetration, imaging speed, and medical applicability. One such technique uses a modified form of simultaneous spatial and temporal focusing (SSTF) to achieve enhanced axial confinement. In SSTF a diffraction grating is imaged onto the sample, and the separation and recombination of the excitation spectral components form a temporal focus. By blocking the central portion of the excitation spectrum, an effective two-color two-photon imaging system is formed. By detecting only the resulting sum frequency generation signal the axial confinement becomes significantly tighter than that achieved by conventional two-photon microscopy. The temporal focus of SSTF may be axially scanned by modulating the group delay dispersion (GDD) of the excitation pulse. In a proof-of-concept experiment, a piezo-bimorph mirror is used to rapidly modulate GDD in a temporal focusing setup. Axial scans over 60 [mu]m of mouse skin are performed at speeds up to 200Hz. This is done through an optical fiber and with no moving parts or electrical components at the distal end, paving the way for the development of a minimally invasive, axial scanning endoscope. Another technique uses frequency multiplexing to perform parallel acquisition of image data using a single-element detector. Five hundred pixels in a line are individually intensity modulated at different radio frequencies. A Fourier transform of the signal unscrambles the image data after detection. In scattering regimes where conventional parallel acquisition (i.e. charge coupled device array, or CCD) methods are impossible, this multifocal multiphoton modulation microscopy (M4) technique allows for higher signal-to-noise ratios and faster imaging. Fluorescent/phosphorescent lifetime can be calculated from the phase component of the Fourier transform in the M4 technique. In combination with the inherent speed advantages of M4, this is used to take full-frame phosphorescent lifetime images of oxygen-sensing dye in vivo in mouse brain vasculature at record speed. ii"]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Parallel Acquisition In Multiphoton Microscopy: Temporal Focusing And Frequency Multiplexing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"97b0266a-088a-4386-8e87-fbf7d2477307\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Parallel Acquisition In Multiphoton Microscopy: Temporal Focusing And Frequency Multiplexing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015-01-26</PublicationDate> <Authors> <Author> <DisplayName>Straub, Adam</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Two-photon</Keyword> <Keyword>Microscopy</Keyword> <Keyword>Temporal Focusing</Keyword> <Abstract>Multiphoton microscopy is a powerful platform for both biological study and medical imaging. Techniques developed on this platform have achieved unparalleled resolution and chemical specificity, imaging at depths unreachable by traditional forms of optical microscopy. This thesis details several techniques meant to improve multiphoton depth penetration, imaging speed, and medical applicability. One such technique uses a modified form of simultaneous spatial and temporal focusing (SSTF) to achieve enhanced axial confinement. In SSTF a diffraction grating is imaged onto the sample, and the separation and recombination of the excitation spectral components form a temporal focus. By blocking the central portion of the excitation spectrum, an effective two-color two-photon imaging system is formed. By detecting only the resulting sum frequency generation signal the axial confinement becomes significantly tighter than that achieved by conventional two-photon microscopy. The temporal focus of SSTF may be axially scanned by modulating the group delay dispersion (GDD) of the excitation pulse. In a proof-of-concept experiment, a piezo-bimorph mirror is used to rapidly modulate GDD in a temporal focusing setup. Axial scans over 60 [mu]m of mouse skin are performed at speeds up to 200Hz. This is done through an optical fiber and with no moving parts or electrical components at the distal end, paving the way for the development of a minimally invasive, axial scanning endoscope. Another technique uses frequency multiplexing to perform parallel acquisition of image data using a single-element detector. Five hundred pixels in a line are individually intensity modulated at different radio frequencies. A Fourier transform of the signal unscrambles the image data after detection. In scattering regimes where conventional parallel acquisition (i.e. charge coupled device array, or CCD) methods are impossible, this multifocal multiphoton modulation microscopy (M4) technique allows for higher signal-to-noise ratios and faster imaging. Fluorescent/phosphorescent lifetime can be calculated from the phase component of the Fourier transform in the M4 technique. In combination with the inherent speed advantages of M4, this is used to take full-frame phosphorescent lifetime images of oxygen-sensing dye in vivo in mouse brain vasculature at record speed. ii</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Straub, Adam"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Xu, Chunhui"],"dc:contributor.committeemember":["Zipfel, Warren R.","Lipson, Michal"],"dc:creator":["Straub, Adam"],"dc:date.accessioned":["2015-04-06T20:13:34Z"],"dc:date.available":["2020-01-27T07:01:03Z"],"dc:date.issued":["2015-01-26"],"dc:description.abstract":["Multiphoton microscopy is a powerful platform for both biological study and medical imaging. Techniques developed on this platform have achieved unparalleled resolution and chemical specificity, imaging at depths unreachable by traditional forms of optical microscopy. This thesis details several techniques meant to improve multiphoton depth penetration, imaging speed, and medical applicability. One such technique uses a modified form of simultaneous spatial and temporal focusing (SSTF) to achieve enhanced axial confinement. In SSTF a diffraction grating is imaged onto the sample, and the separation and recombination of the excitation spectral components form a temporal focus. By blocking the central portion of the excitation spectrum, an effective two-color two-photon imaging system is formed. By detecting only the resulting sum frequency generation signal the axial confinement becomes significantly tighter than that achieved by conventional two-photon microscopy. The temporal focus of SSTF may be axially scanned by modulating the group delay dispersion (GDD) of the excitation pulse. In a proof-of-concept experiment, a piezo-bimorph mirror is used to rapidly modulate GDD in a temporal focusing setup. Axial scans over 60 [mu]m of mouse skin are performed at speeds up to 200Hz. This is done through an optical fiber and with no moving parts or electrical components at the distal end, paving the way for the development of a minimally invasive, axial scanning endoscope. Another technique uses frequency multiplexing to perform parallel acquisition of image data using a single-element detector. Five hundred pixels in a line are individually intensity modulated at different radio frequencies. A Fourier transform of the signal unscrambles the image data after detection. In scattering regimes where conventional parallel acquisition (i.e. charge coupled device array, or CCD) methods are impossible, this multifocal multiphoton modulation microscopy (M4) technique allows for higher signal-to-noise ratios and faster imaging. Fluorescent/phosphorescent lifetime can be calculated from the phase component of the Fourier transform in the M4 technique. In combination with the inherent speed advantages of M4, this is used to take full-frame phosphorescent lifetime images of oxygen-sensing dye in vivo in mouse brain vasculature at record speed. ii"],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9154380"],"dc:identifier.uri":["https://hdl.handle.net/1813/39303"],"dc:language.iso":["en_US"],"dc:subject":["Two-photon","Microscopy","Temporal Focusing"],"dc:title":["Parallel Acquisition In Multiphoton Microscopy: Temporal Focusing And Frequency Multiplexing"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Applied Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:04Z"}