{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/39453"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/39453","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Production Of Micellar Casein Concentrates Using Ceramic Microfiltration Membranes: Optimal Process Design And System Operation","abstract":"Microfiltration of skim milk using 0.1 [MICRO SIGN]m ceramic membranes can separate micellar casein from serum protein. Both the micellar casein and serum proteins may be valuable food ingredients. To improve the commercial viability of the microfiltration process, the system should be designed and operated to minimize fixed (e.g., membrane area) and variable (i.e., energy) costs. As a first step, to determine what factors were important in process design, a theoretical model for the production of a micellar casein concentrate was developed. From the theoretical model it was determined that the use of ultrafiltration of skim milk prior to microfiltration could reduce the membrane area required. Additionally, it was found that the increasing following factors: number of stages, flux, and recirculation loop protein concentration further decreased the required membrane area. Finally, if the microfiltration feed was ultrafiltered skim milk, it was found that the optimal microfiltration feed protein concentration was 5.4% protein for a 5-stage process. The next step was to evaluate the performance of ceramic graded permeability membranes with 3 mm and 4 mm channel diameters, by determining the limiting flux and serum protein removal at 8, 9 and 10% protein in the recirculation loop. The microfiltration feed was an ultrafiltered skim milk. The limiting flux decreased by approximately 24% as the recirculation loop protein concentration was increased from 8% to 10% for both the 3 mm and 4 mm channel diameter membranes. At each protein concentration the limiting flux was about 20% higher with the 4 mm compared to 3 mm channel diameter membranes. Additionally, the serum protein removal factor was higher on the 4 mm than 3 mm channel diameter membranes. Finally, the impact of increasing the temperature of microfiltration above 50 oC on membrane fouling and serum protein removal was determined. Increasing the temperature up to 65oC did not cause any detectable membrane fouling. Increasing the temperature of microfiltration decreased serum protein removal. However, higher temperature also decreased casein concentration in the permeate. Based on this work, it may be feasible to increase the temperature of microfiltration and possibly the microfiltration flux.","abstract_html":"Microfiltration of skim milk using 0.1 [MICRO SIGN]m ceramic membranes can separate micellar casein from serum protein. Both the micellar casein and serum proteins may be valuable food ingredients. To improve the commercial viability of the microfiltration process, the system should be designed and operated to minimize fixed (e.g., membrane area) and variable (i.e., energy) costs. As a first step, to determine what factors were important in process design, a theoretical model for the production of a micellar casein concentrate was developed. From the theoretical model it was determined that the use of ultrafiltration of skim milk prior to microfiltration could reduce the membrane area required. Additionally, it was found that the increasing following factors: number of stages, flux, and recirculation loop protein concentration further decreased the required membrane area. Finally, if the microfiltration feed was ultrafiltered skim milk, it was found that the optimal microfiltration feed protein concentration was 5.4% protein for a 5-stage process. The next step was to evaluate the performance of ceramic graded permeability membranes with 3 mm and 4 mm channel diameters, by determining the limiting flux and serum protein removal at 8, 9 and 10% protein in the recirculation loop. The microfiltration feed was an ultrafiltered skim milk. The limiting flux decreased by approximately 24% as the recirculation loop protein concentration was increased from 8% to 10% for both the 3 mm and 4 mm channel diameter membranes. At each protein concentration the limiting flux was about 20% higher with the 4 mm compared to 3 mm channel diameter membranes. Additionally, the serum protein removal factor was higher on the 4 mm than 3 mm channel diameter membranes. Finally, the impact of increasing the temperature of microfiltration above 50 oC on membrane fouling and serum protein removal was determined. Increasing the temperature up to 65oC did not cause any detectable membrane fouling. Increasing the temperature of microfiltration decreased serum protein removal. However, higher temperature also decreased casein concentration in the permeate. Based on this work, it may be feasible to increase the temperature of microfiltration and possibly the microfiltration flux.","abstract_has_math":false,"creators":["Hurt, Emily"],"institution":"Cornell University","degree_name":"Ph. D., Food Science and Technology","degree_level":"Doctor of Philosophy","degree_discipline":"Food Science and Technology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Barbano, David Mark"],"committee_members":["Datta, Ashim K","Miller, Dennis D.","Novakovic, Andrew Milovan"],"year":2015,"date_issued":"2015-01-26","date_published":"2015-01-26","updated_at":"2026-11-19T03:18:46Z","subjects":["Microfiltration","Micellar casein concentrate","Serum protein"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9154415"],"render_values":[{"text":"9154415","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/39453","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/39453","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F39453","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Barbano, David Mark"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Datta, Ashim K","Miller, Dennis D.","Novakovic, Andrew Milovan"]},{"key":"dc:creator","label":"Author","values":["Hurt, Emily"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-04-06T20:15:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-04-06T20:15:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-01-26"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Food Science and Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Food Science and Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfiltration","Micellar casein concentrate","Serum protein"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9154415"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/39453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a13e30ce-e4b3-4977-ad92-4c60cd3aae3b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Production Of Micellar Casein Concentrates Using Ceramic Microfiltration Membranes: Optimal Process Design And System Operation</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015-01-26</PublicationDate> <Authors> <Author> <DisplayName>Hurt, Emily</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Microfiltration</Keyword> <Keyword>Micellar casein concentrate</Keyword> <Keyword>Serum protein</Keyword> <Abstract>Microfiltration of skim milk using 0.1 [MICRO SIGN]m ceramic membranes can separate micellar casein from serum protein. Both the micellar casein and serum proteins may be valuable food ingredients. To improve the commercial viability of the microfiltration process, the system should be designed and operated to minimize fixed (e.g., membrane area) and variable (i.e., energy) costs. As a first step, to determine what factors were important in process design, a theoretical model for the production of a micellar casein concentrate was developed. From the theoretical model it was determined that the use of ultrafiltration of skim milk prior to microfiltration could reduce the membrane area required. Additionally, it was found that the increasing following factors: number of stages, flux, and recirculation loop protein concentration further decreased the required membrane area. Finally, if the microfiltration feed was ultrafiltered skim milk, it was found that the optimal microfiltration feed protein concentration was 5.4% protein for a 5-stage process. The next step was to evaluate the performance of ceramic graded permeability membranes with 3 mm and 4 mm channel diameters, by determining the limiting flux and serum protein removal at 8, 9 and 10% protein in the recirculation loop. The microfiltration feed was an ultrafiltered skim milk. The limiting flux decreased by approximately 24% as the recirculation loop protein concentration was increased from 8% to 10% for both the 3 mm and 4 mm channel diameter membranes. At each protein concentration the limiting flux was about 20% higher with the 4 mm compared to 3 mm channel diameter membranes. Additionally, the serum protein removal factor was higher on the 4 mm than 3 mm channel diameter membranes. Finally, the impact of increasing the temperature of microfiltration above 50 oC on membrane fouling and serum protein removal was determined. Increasing the temperature up to 65oC did not cause any detectable membrane fouling. Increasing the temperature of microfiltration decreased serum protein removal. However, higher temperature also decreased casein concentration in the permeate. Based on this work, it may be feasible to increase the temperature of microfiltration and possibly the microfiltration flux.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Hurt, Emily"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Microfiltration of skim milk using 0.1 [MICRO SIGN]m ceramic membranes can separate micellar casein from serum protein. Both the micellar casein and serum proteins may be valuable food ingredients. To improve the commercial viability of the microfiltration process, the system should be designed and operated to minimize fixed (e.g., membrane area) and variable (i.e., energy) costs. As a first step, to determine what factors were important in process design, a theoretical model for the production of a micellar casein concentrate was developed. From the theoretical model it was determined that the use of ultrafiltration of skim milk prior to microfiltration could reduce the membrane area required. Additionally, it was found that the increasing following factors: number of stages, flux, and recirculation loop protein concentration further decreased the required membrane area. Finally, if the microfiltration feed was ultrafiltered skim milk, it was found that the optimal microfiltration feed protein concentration was 5.4% protein for a 5-stage process. The next step was to evaluate the performance of ceramic graded permeability membranes with 3 mm and 4 mm channel diameters, by determining the limiting flux and serum protein removal at 8, 9 and 10% protein in the recirculation loop. The microfiltration feed was an ultrafiltered skim milk. The limiting flux decreased by approximately 24% as the recirculation loop protein concentration was increased from 8% to 10% for both the 3 mm and 4 mm channel diameter membranes. At each protein concentration the limiting flux was about 20% higher with the 4 mm compared to 3 mm channel diameter membranes. Additionally, the serum protein removal factor was higher on the 4 mm than 3 mm channel diameter membranes. Finally, the impact of increasing the temperature of microfiltration above 50 oC on membrane fouling and serum protein removal was determined. Increasing the temperature up to 65oC did not cause any detectable membrane fouling. Increasing the temperature of microfiltration decreased serum protein removal. However, higher temperature also decreased casein concentration in the permeate. Based on this work, it may be feasible to increase the temperature of microfiltration and possibly the microfiltration flux."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Production Of Micellar Casein Concentrates Using Ceramic Microfiltration Membranes: Optimal Process Design And System Operation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"a13e30ce-e4b3-4977-ad92-4c60cd3aae3b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Production Of Micellar Casein Concentrates Using Ceramic Microfiltration Membranes: Optimal Process Design And System Operation</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015-01-26</PublicationDate> <Authors> <Author> <DisplayName>Hurt, Emily</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Microfiltration</Keyword> <Keyword>Micellar casein concentrate</Keyword> <Keyword>Serum protein</Keyword> <Abstract>Microfiltration of skim milk using 0.1 [MICRO SIGN]m ceramic membranes can separate micellar casein from serum protein. Both the micellar casein and serum proteins may be valuable food ingredients. To improve the commercial viability of the microfiltration process, the system should be designed and operated to minimize fixed (e.g., membrane area) and variable (i.e., energy) costs. As a first step, to determine what factors were important in process design, a theoretical model for the production of a micellar casein concentrate was developed. From the theoretical model it was determined that the use of ultrafiltration of skim milk prior to microfiltration could reduce the membrane area required. Additionally, it was found that the increasing following factors: number of stages, flux, and recirculation loop protein concentration further decreased the required membrane area. Finally, if the microfiltration feed was ultrafiltered skim milk, it was found that the optimal microfiltration feed protein concentration was 5.4% protein for a 5-stage process. The next step was to evaluate the performance of ceramic graded permeability membranes with 3 mm and 4 mm channel diameters, by determining the limiting flux and serum protein removal at 8, 9 and 10% protein in the recirculation loop. The microfiltration feed was an ultrafiltered skim milk. The limiting flux decreased by approximately 24% as the recirculation loop protein concentration was increased from 8% to 10% for both the 3 mm and 4 mm channel diameter membranes. At each protein concentration the limiting flux was about 20% higher with the 4 mm compared to 3 mm channel diameter membranes. Additionally, the serum protein removal factor was higher on the 4 mm than 3 mm channel diameter membranes. Finally, the impact of increasing the temperature of microfiltration above 50 oC on membrane fouling and serum protein removal was determined. Increasing the temperature up to 65oC did not cause any detectable membrane fouling. Increasing the temperature of microfiltration decreased serum protein removal. However, higher temperature also decreased casein concentration in the permeate. Based on this work, it may be feasible to increase the temperature of microfiltration and possibly the microfiltration flux.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Hurt, Emily"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Barbano, David Mark"],"dc:contributor.committeemember":["Datta, Ashim K","Miller, Dennis D.","Novakovic, Andrew Milovan"],"dc:creator":["Hurt, Emily"],"dc:date.accessioned":["2015-04-06T20:15:52Z"],"dc:date.available":["2015-04-06T20:15:52Z"],"dc:date.issued":["2015-01-26"],"dc:description.abstract":["Microfiltration of skim milk using 0.1 [MICRO SIGN]m ceramic membranes can separate micellar casein from serum protein. Both the micellar casein and serum proteins may be valuable food ingredients. To improve the commercial viability of the microfiltration process, the system should be designed and operated to minimize fixed (e.g., membrane area) and variable (i.e., energy) costs. As a first step, to determine what factors were important in process design, a theoretical model for the production of a micellar casein concentrate was developed. From the theoretical model it was determined that the use of ultrafiltration of skim milk prior to microfiltration could reduce the membrane area required. Additionally, it was found that the increasing following factors: number of stages, flux, and recirculation loop protein concentration further decreased the required membrane area. Finally, if the microfiltration feed was ultrafiltered skim milk, it was found that the optimal microfiltration feed protein concentration was 5.4% protein for a 5-stage process. The next step was to evaluate the performance of ceramic graded permeability membranes with 3 mm and 4 mm channel diameters, by determining the limiting flux and serum protein removal at 8, 9 and 10% protein in the recirculation loop. The microfiltration feed was an ultrafiltered skim milk. The limiting flux decreased by approximately 24% as the recirculation loop protein concentration was increased from 8% to 10% for both the 3 mm and 4 mm channel diameter membranes. At each protein concentration the limiting flux was about 20% higher with the 4 mm compared to 3 mm channel diameter membranes. Additionally, the serum protein removal factor was higher on the 4 mm than 3 mm channel diameter membranes. Finally, the impact of increasing the temperature of microfiltration above 50 oC on membrane fouling and serum protein removal was determined. Increasing the temperature up to 65oC did not cause any detectable membrane fouling. Increasing the temperature of microfiltration decreased serum protein removal. However, higher temperature also decreased casein concentration in the permeate. Based on this work, it may be feasible to increase the temperature of microfiltration and possibly the microfiltration flux."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9154415"],"dc:identifier.uri":["https://hdl.handle.net/1813/39453"],"dc:language.iso":["en_US"],"dc:subject":["Microfiltration","Micellar casein concentrate","Serum protein"],"dc:title":["Production Of Micellar Casein Concentrates Using Ceramic Microfiltration Membranes: Optimal Process Design And System Operation"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Food Science and Technology"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Food Science and Technology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:46Z"}