{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/41128"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/41128","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"The Effects Of Ceramic Membrane Design And Feed Composition On Serum Protein Removal During Microfiltration Of Skim Milk","abstract":"Ceramic microfiltration (MF) membranes were used to separate serum proteins (SP) from casein (CN) micelles in skim milk. The impact of skim milk soluble calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein concentration (LRPC)) were determined. Skim milk LF (91 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) was lower than milk protein concentrate with added lactose (MPC+L) LF (124 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to a reduction in calcium. MPC+L LF was lower than milk protein concentrate (MPC) LF (137 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to the higher viscosity contributed by lactose. No differences in SP removal were detected among the 3 feeds below the LF. Feeding a MF system with MPC instead of skim milk will reduce the membrane surface area required to process a given volume of milk. Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP increased LF by 5%, but SP removal was not affected. Using round instead of diamond channel membranes increased LF by 24%. The 47% increase in membrane area per unit volume of the diamond channel system resulted in its higher (19%) modular permeate removal rate. Using membranes with diamond channels could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used. Retentate flow channel diameter did not affect the LRPC at constant cross-flow velocity. At a given longitudinal pressure drop, 6 mm membranes could achieve a higher cross-flow velocity and, thus, a higher LRPC than 4 mm membranes. The higher LRPC of 6 mm membranes might facilitate 95% SP removal in 2 MF stages. 4 mm membranes require 21% more energy than 6 mm membranes to remove a given amount of permeate. Using 6 mm membranes would be advantageous for processors wishing to reduce energy costs or maximize protein concentrations in MF retentates.","abstract_html":"Ceramic microfiltration (MF) membranes were used to separate serum proteins (SP) from casein (CN) micelles in skim milk. The impact of skim milk soluble calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein concentration (LRPC)) were determined. Skim milk LF (91 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) was lower than milk protein concentrate with added lactose (MPC+L) LF (124 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to a reduction in calcium. MPC+L LF was lower than milk protein concentrate (MPC) LF (137 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to the higher viscosity contributed by lactose. No differences in SP removal were detected among the 3 feeds below the LF. Feeding a MF system with MPC instead of skim milk will reduce the membrane surface area required to process a given volume of milk. Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP increased LF by 5%, but SP removal was not affected. Using round instead of diamond channel membranes increased LF by 24%. The 47% increase in membrane area per unit volume of the diamond channel system resulted in its higher (19%) modular permeate removal rate. Using membranes with diamond channels could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used. Retentate flow channel diameter did not affect the LRPC at constant cross-flow velocity. At a given longitudinal pressure drop, 6 mm membranes could achieve a higher cross-flow velocity and, thus, a higher LRPC than 4 mm membranes. The higher LRPC of 6 mm membranes might facilitate 95% SP removal in 2 MF stages. 4 mm membranes require 21% more energy than 6 mm membranes to remove a given amount of permeate. Using 6 mm membranes would be advantageous for processors wishing to reduce energy costs or maximize protein concentrations in MF retentates.","abstract_has_math":false,"creators":["Adams, Michael"],"institution":"Cornell University","degree_name":"Ph. D., Food Science and Technology","degree_level":"Doctor of Philosophy","degree_discipline":"Food Science and Technology","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Barbano,David Mark"],"committee_members":["Liaukonyte,Jurate","Datta,Ashim K"],"year":2015,"date_issued":"2015-08-17","date_published":"2015-08-17","updated_at":"2026-11-19T03:18:46Z","subjects":["microfiltration","ceramic membranes","dairy"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9333177"],"render_values":[{"text":"9333177","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/41128","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/41128","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F41128","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Barbano,David Mark"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Liaukonyte,Jurate","Datta,Ashim K"]},{"key":"dc:creator","label":"Author","values":["Adams, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-10-15T18:11:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-08-17T06:00:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-08-17"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Food Science and Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Food Science and Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microfiltration","ceramic membranes","dairy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9333177"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/41128"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9103e945-e8b8-4358-91f0-f6014386479c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>The Effects Of Ceramic Membrane Design And Feed Composition On Serum Protein Removal During Microfiltration Of Skim Milk</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015-08-17</PublicationDate> <Authors> <Author> <DisplayName>Adams, Michael</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfiltration</Keyword> <Keyword>ceramic membranes</Keyword> <Keyword>dairy</Keyword> <Abstract>Ceramic microfiltration (MF) membranes were used to separate serum proteins (SP) from casein (CN) micelles in skim milk. The impact of skim milk soluble calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein concentration (LRPC)) were determined. Skim milk LF (91 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) was lower than milk protein concentrate with added lactose (MPC+L) LF (124 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to a reduction in calcium. MPC+L LF was lower than milk protein concentrate (MPC) LF (137 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to the higher viscosity contributed by lactose. No differences in SP removal were detected among the 3 feeds below the LF. Feeding a MF system with MPC instead of skim milk will reduce the membrane surface area required to process a given volume of milk. Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP increased LF by 5%, but SP removal was not affected. Using round instead of diamond channel membranes increased LF by 24%. The 47% increase in membrane area per unit volume of the diamond channel system resulted in its higher (19%) modular permeate removal rate. Using membranes with diamond channels could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used. Retentate flow channel diameter did not affect the LRPC at constant cross-flow velocity. At a given longitudinal pressure drop, 6 mm membranes could achieve a higher cross-flow velocity and, thus, a higher LRPC than 4 mm membranes. The higher LRPC of 6 mm membranes might facilitate 95% SP removal in 2 MF stages. 4 mm membranes require 21% more energy than 6 mm membranes to remove a given amount of permeate. Using 6 mm membranes would be advantageous for processors wishing to reduce energy costs or maximize protein concentrations in MF retentates.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Adams, Michael"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Ceramic microfiltration (MF) membranes were used to separate serum proteins (SP) from casein (CN) micelles in skim milk. The impact of skim milk soluble calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein concentration (LRPC)) were determined. Skim milk LF (91 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) was lower than milk protein concentrate with added lactose (MPC+L) LF (124 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to a reduction in calcium. MPC+L LF was lower than milk protein concentrate (MPC) LF (137 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to the higher viscosity contributed by lactose. No differences in SP removal were detected among the 3 feeds below the LF. Feeding a MF system with MPC instead of skim milk will reduce the membrane surface area required to process a given volume of milk. Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP increased LF by 5%, but SP removal was not affected. Using round instead of diamond channel membranes increased LF by 24%. The 47% increase in membrane area per unit volume of the diamond channel system resulted in its higher (19%) modular permeate removal rate. Using membranes with diamond channels could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used. Retentate flow channel diameter did not affect the LRPC at constant cross-flow velocity. At a given longitudinal pressure drop, 6 mm membranes could achieve a higher cross-flow velocity and, thus, a higher LRPC than 4 mm membranes. The higher LRPC of 6 mm membranes might facilitate 95% SP removal in 2 MF stages. 4 mm membranes require 21% more energy than 6 mm membranes to remove a given amount of permeate. Using 6 mm membranes would be advantageous for processors wishing to reduce energy costs or maximize protein concentrations in MF retentates."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The Effects Of Ceramic Membrane Design And Feed Composition On Serum Protein Removal During Microfiltration Of Skim Milk"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"9103e945-e8b8-4358-91f0-f6014386479c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>The Effects Of Ceramic Membrane Design And Feed Composition On Serum Protein Removal During Microfiltration Of Skim Milk</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015-08-17</PublicationDate> <Authors> <Author> <DisplayName>Adams, Michael</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>microfiltration</Keyword> <Keyword>ceramic membranes</Keyword> <Keyword>dairy</Keyword> <Abstract>Ceramic microfiltration (MF) membranes were used to separate serum proteins (SP) from casein (CN) micelles in skim milk. The impact of skim milk soluble calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein concentration (LRPC)) were determined. Skim milk LF (91 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) was lower than milk protein concentrate with added lactose (MPC+L) LF (124 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to a reduction in calcium. MPC+L LF was lower than milk protein concentrate (MPC) LF (137 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to the higher viscosity contributed by lactose. No differences in SP removal were detected among the 3 feeds below the LF. Feeding a MF system with MPC instead of skim milk will reduce the membrane surface area required to process a given volume of milk. Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP increased LF by 5%, but SP removal was not affected. Using round instead of diamond channel membranes increased LF by 24%. The 47% increase in membrane area per unit volume of the diamond channel system resulted in its higher (19%) modular permeate removal rate. Using membranes with diamond channels could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used. Retentate flow channel diameter did not affect the LRPC at constant cross-flow velocity. At a given longitudinal pressure drop, 6 mm membranes could achieve a higher cross-flow velocity and, thus, a higher LRPC than 4 mm membranes. The higher LRPC of 6 mm membranes might facilitate 95% SP removal in 2 MF stages. 4 mm membranes require 21% more energy than 6 mm membranes to remove a given amount of permeate. Using 6 mm membranes would be advantageous for processors wishing to reduce energy costs or maximize protein concentrations in MF retentates.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Adams, Michael"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Barbano,David Mark"],"dc:contributor.committeemember":["Liaukonyte,Jurate","Datta,Ashim K"],"dc:creator":["Adams, Michael"],"dc:date.accessioned":["2015-10-15T18:11:25Z"],"dc:date.available":["2020-08-17T06:00:50Z"],"dc:date.issued":["2015-08-17"],"dc:description.abstract":["Ceramic microfiltration (MF) membranes were used to separate serum proteins (SP) from casein (CN) micelles in skim milk. The impact of skim milk soluble calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein concentration (LRPC)) were determined. Skim milk LF (91 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) was lower than milk protein concentrate with added lactose (MPC+L) LF (124 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to a reduction in calcium. MPC+L LF was lower than milk protein concentrate (MPC) LF (137 kg[MIDDLE DOT]m-2[MIDDLE DOT]h-1) due to the higher viscosity contributed by lactose. No differences in SP removal were detected among the 3 feeds below the LF. Feeding a MF system with MPC instead of skim milk will reduce the membrane surface area required to process a given volume of milk. Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP increased LF by 5%, but SP removal was not affected. Using round instead of diamond channel membranes increased LF by 24%. The 47% increase in membrane area per unit volume of the diamond channel system resulted in its higher (19%) modular permeate removal rate. Using membranes with diamond channels could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used. Retentate flow channel diameter did not affect the LRPC at constant cross-flow velocity. At a given longitudinal pressure drop, 6 mm membranes could achieve a higher cross-flow velocity and, thus, a higher LRPC than 4 mm membranes. The higher LRPC of 6 mm membranes might facilitate 95% SP removal in 2 MF stages. 4 mm membranes require 21% more energy than 6 mm membranes to remove a given amount of permeate. Using 6 mm membranes would be advantageous for processors wishing to reduce energy costs or maximize protein concentrations in MF retentates."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9333177"],"dc:identifier.uri":["https://hdl.handle.net/1813/41128"],"dc:language.iso":["en_US"],"dc:subject":["microfiltration","ceramic membranes","dairy"],"dc:title":["The Effects Of Ceramic Membrane Design And Feed Composition On Serum Protein Removal During Microfiltration Of Skim Milk"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Food Science and Technology"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Food Science and Technology"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:18:46Z"}