{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/43589"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/43589","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Using Picosecond Heat Pulses To Measure Magnetization","abstract":"Recent advances in nanoscale magnetism have demonstrated the potential for spin-based technology. Future engineering advances and new scientific discoveries will require research tools capable of examining local magnetization dynamics at length and time scales fundamental to magnetic systems, which is typically 10-200 nm and 5-50 ps. A key problem is that current table-top magnetic microscopy cannot access both of these scales simultaneously. In this thesis, we introduce a spatiotemporal magnetic microscopy technique which uses magneto-thermoelectric interactions to measure local magnetization via the time-resolved anomalous Nernst effect (TRANE). By generating a shortlived, local temperature gradient, the magnetic moment is transduced into an electrical signal. Experimentally, we show that TRANE microscopy has time resolution below 30 ps and spatial resolution limited by the thermal excitation area. Furthermore, we present numerical simulations to show that the thermal spot size sets the limits of the spatial resolution down to 50 nm. The thermal effects used for TRANE microscopy have no fundamental limit on their spatial resolution, therefore a future TRANE microscope employing a scanning plasmon antenna could enable measurements of nanoscale magnetic dynamics.","abstract_html":"Recent advances in nanoscale magnetism have demonstrated the potential for spin-based technology. Future engineering advances and new scientific discoveries will require research tools capable of examining local magnetization dynamics at length and time scales fundamental to magnetic systems, which is typically 10-200 nm and 5-50 ps. A key problem is that current table-top magnetic microscopy cannot access both of these scales simultaneously. In this thesis, we introduce a spatiotemporal magnetic microscopy technique which uses magneto-thermoelectric interactions to measure local magnetization via the time-resolved anomalous Nernst effect (TRANE). By generating a shortlived, local temperature gradient, the magnetic moment is transduced into an electrical signal. Experimentally, we show that TRANE microscopy has time resolution below 30 ps and spatial resolution limited by the thermal excitation area. Furthermore, we present numerical simulations to show that the thermal spot size sets the limits of the spatial resolution down to 50 nm. The thermal effects used for TRANE microscopy have no fundamental limit on their spatial resolution, therefore a future TRANE microscope employing a scanning plasmon antenna could enable measurements of nanoscale magnetic dynamics.","abstract_has_math":false,"creators":["Ngai, Darryl"],"institution":"Cornell University","degree_name":"Ph. D., Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Ralph,Daniel C"],"committee_members":["Fuchs,Gregory David","Kim,Eun-Ah"],"year":2016,"date_issued":"2016-02-01","date_published":"2016-02-01","updated_at":"2026-11-19T03:19:03Z","subjects":["Magnetism","Microscopy","Anomlaous Nernst Effect"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9596997"],"render_values":[{"text":"9596997","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/43589","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/43589","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F43589","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Ralph,Daniel C"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Fuchs,Gregory David","Kim,Eun-Ah"]},{"key":"dc:creator","label":"Author","values":["Ngai, Darryl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-04-04T18:05:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-04-04T18:05:08Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-02-01"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Magnetism","Microscopy","Anomlaous Nernst Effect"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9596997"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/43589"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b807dac7-8d2b-44f5-a770-d96989879cca\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Using Picosecond Heat Pulses To Measure Magnetization</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Ngai, Darryl</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Magnetism</Keyword> <Keyword>Microscopy</Keyword> <Keyword>Anomlaous Nernst Effect</Keyword> <Abstract>Recent advances in nanoscale magnetism have demonstrated the potential for spin-based technology. Future engineering advances and new scientific discoveries will require research tools capable of examining local magnetization dynamics at length and time scales fundamental to magnetic systems, which is typically 10-200 nm and 5-50 ps. A key problem is that current table-top magnetic microscopy cannot access both of these scales simultaneously. In this thesis, we introduce a spatiotemporal magnetic microscopy technique which uses magneto-thermoelectric interactions to measure local magnetization via the time-resolved anomalous Nernst effect (TRANE). By generating a shortlived, local temperature gradient, the magnetic moment is transduced into an electrical signal. Experimentally, we show that TRANE microscopy has time resolution below 30 ps and spatial resolution limited by the thermal excitation area. Furthermore, we present numerical simulations to show that the thermal spot size sets the limits of the spatial resolution down to 50 nm. The thermal effects used for TRANE microscopy have no fundamental limit on their spatial resolution, therefore a future TRANE microscope employing a scanning plasmon antenna could enable measurements of nanoscale magnetic dynamics.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Ngai, Darryl"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Recent advances in nanoscale magnetism have demonstrated the potential for spin-based technology. Future engineering advances and new scientific discoveries will require research tools capable of examining local magnetization dynamics at length and time scales fundamental to magnetic systems, which is typically 10-200 nm and 5-50 ps. A key problem is that current table-top magnetic microscopy cannot access both of these scales simultaneously. In this thesis, we introduce a spatiotemporal magnetic microscopy technique which uses magneto-thermoelectric interactions to measure local magnetization via the time-resolved anomalous Nernst effect (TRANE). By generating a shortlived, local temperature gradient, the magnetic moment is transduced into an electrical signal. Experimentally, we show that TRANE microscopy has time resolution below 30 ps and spatial resolution limited by the thermal excitation area. Furthermore, we present numerical simulations to show that the thermal spot size sets the limits of the spatial resolution down to 50 nm. The thermal effects used for TRANE microscopy have no fundamental limit on their spatial resolution, therefore a future TRANE microscope employing a scanning plasmon antenna could enable measurements of nanoscale magnetic dynamics."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Using Picosecond Heat Pulses To Measure Magnetization"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"b807dac7-8d2b-44f5-a770-d96989879cca\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Using Picosecond Heat Pulses To Measure Magnetization</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Ngai, Darryl</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Magnetism</Keyword> <Keyword>Microscopy</Keyword> <Keyword>Anomlaous Nernst Effect</Keyword> <Abstract>Recent advances in nanoscale magnetism have demonstrated the potential for spin-based technology. Future engineering advances and new scientific discoveries will require research tools capable of examining local magnetization dynamics at length and time scales fundamental to magnetic systems, which is typically 10-200 nm and 5-50 ps. A key problem is that current table-top magnetic microscopy cannot access both of these scales simultaneously. In this thesis, we introduce a spatiotemporal magnetic microscopy technique which uses magneto-thermoelectric interactions to measure local magnetization via the time-resolved anomalous Nernst effect (TRANE). By generating a shortlived, local temperature gradient, the magnetic moment is transduced into an electrical signal. Experimentally, we show that TRANE microscopy has time resolution below 30 ps and spatial resolution limited by the thermal excitation area. Furthermore, we present numerical simulations to show that the thermal spot size sets the limits of the spatial resolution down to 50 nm. The thermal effects used for TRANE microscopy have no fundamental limit on their spatial resolution, therefore a future TRANE microscope employing a scanning plasmon antenna could enable measurements of nanoscale magnetic dynamics.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Ngai, Darryl"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Ralph,Daniel C"],"dc:contributor.committeemember":["Fuchs,Gregory David","Kim,Eun-Ah"],"dc:creator":["Ngai, Darryl"],"dc:date.accessioned":["2016-04-04T18:05:08Z"],"dc:date.available":["2016-04-04T18:05:08Z"],"dc:date.issued":["2016-02-01"],"dc:description.abstract":["Recent advances in nanoscale magnetism have demonstrated the potential for spin-based technology. Future engineering advances and new scientific discoveries will require research tools capable of examining local magnetization dynamics at length and time scales fundamental to magnetic systems, which is typically 10-200 nm and 5-50 ps. A key problem is that current table-top magnetic microscopy cannot access both of these scales simultaneously. In this thesis, we introduce a spatiotemporal magnetic microscopy technique which uses magneto-thermoelectric interactions to measure local magnetization via the time-resolved anomalous Nernst effect (TRANE). By generating a shortlived, local temperature gradient, the magnetic moment is transduced into an electrical signal. Experimentally, we show that TRANE microscopy has time resolution below 30 ps and spatial resolution limited by the thermal excitation area. Furthermore, we present numerical simulations to show that the thermal spot size sets the limits of the spatial resolution down to 50 nm. The thermal effects used for TRANE microscopy have no fundamental limit on their spatial resolution, therefore a future TRANE microscope employing a scanning plasmon antenna could enable measurements of nanoscale magnetic dynamics."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9596997"],"dc:identifier.uri":["https://hdl.handle.net/1813/43589"],"dc:language.iso":["en_US"],"dc:subject":["Magnetism","Microscopy","Anomlaous Nernst Effect"],"dc:title":["Using Picosecond Heat Pulses To Measure Magnetization"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:03Z"}