{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/43631"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/43631","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Development Of Low Temperature Biological Small Angle X-Ray Scattering, Cryosaxs, And Study Of Ice Formation In Aqueous Solutions","abstract":"This dissertation is based on the study of biological systems and aqueous solutions at low temperatures. The focus of the dissertation is on the continued development of low temperature biological small angle X-ray scattering (SAXS), cryoSAXS. CryoSAXS is a new method for biological SAXS that involves cryocooling the sample to 100 K. At 100 K the sample is much more resistant to damage from X-rays, enabling use of volumes hundreds or thousands of times smaller than in conventional room temperature SAXS. This work was divided into three main pieces. First, we designed, microfabricated, and tested new small volume, fixed path length sample holder for use in cryoSAXS. Next, as a first step towards answering the question of how much the radiation tolerance of a sample increases upon cryocooling, we developed methods to quantify radiation damage to SAXS profiles and tested these using standard room temperature SAXS. Finally, we measured the radiation tolerance of cryocooled SAXS samples, and found that the cryocooling decreases the radiation sensitivity by three orders of magnitude. The last chapter of the dissertation describes ongoing work to develop time resolved cryoSAXS, and other outstanding questions in cryoSAXS. In addition to cryoSAXS, in a complementary research project we studied ice formation in aqueous solutions. In particular, we quantified the critical warming rate, the warming rate required to prevent ice formation upon warming a vitrified solution. This has particular relevance to biological cryopreservation, as ice formation can irreparably damage cryopreserved samples.","abstract_html":"This dissertation is based on the study of biological systems and aqueous solutions at low temperatures. The focus of the dissertation is on the continued development of low temperature biological small angle X-ray scattering (SAXS), cryoSAXS. CryoSAXS is a new method for biological SAXS that involves cryocooling the sample to 100 K. At 100 K the sample is much more resistant to damage from X-rays, enabling use of volumes hundreds or thousands of times smaller than in conventional room temperature SAXS. This work was divided into three main pieces. First, we designed, microfabricated, and tested new small volume, fixed path length sample holder for use in cryoSAXS. Next, as a first step towards answering the question of how much the radiation tolerance of a sample increases upon cryocooling, we developed methods to quantify radiation damage to SAXS profiles and tested these using standard room temperature SAXS. Finally, we measured the radiation tolerance of cryocooled SAXS samples, and found that the cryocooling decreases the radiation sensitivity by three orders of magnitude. The last chapter of the dissertation describes ongoing work to develop time resolved cryoSAXS, and other outstanding questions in cryoSAXS. In addition to cryoSAXS, in a complementary research project we studied ice formation in aqueous solutions. In particular, we quantified the critical warming rate, the warming rate required to prevent ice formation upon warming a vitrified solution. This has particular relevance to biological cryopreservation, as ice formation can irreparably damage cryopreserved samples.","abstract_has_math":false,"creators":["Hopkins, Jesse"],"institution":"Cornell University","degree_name":"Ph. D., Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Thorne,Robert Edward"],"committee_members":["Sethna,James Patarasp","Shen,Kyle M.","Pollack,Lois"],"year":2016,"date_issued":"2016-02-01","date_published":"2016-02-01","updated_at":"2026-11-19T03:19:03Z","subjects":["cryosaxs","small-angle x-ray scattering","ice formation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597082"],"render_values":[{"text":"9597082","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/43631","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/43631","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F43631","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Thorne,Robert Edward"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sethna,James Patarasp","Shen,Kyle M.","Pollack,Lois"]},{"key":"dc:creator","label":"Author","values":["Hopkins, Jesse"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-04-04T18:05:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-01T07:00:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-02-01"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cryosaxs","small-angle x-ray scattering","ice formation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597082"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/43631"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3ed28909-d0df-449d-8fdb-ec60b4c748cf\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development Of Low Temperature Biological Small Angle X-Ray Scattering, Cryosaxs, And Study Of Ice Formation In Aqueous Solutions</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Hopkins, Jesse</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>cryosaxs</Keyword> <Keyword>small-angle x-ray scattering</Keyword> <Keyword>ice formation</Keyword> <Abstract>This dissertation is based on the study of biological systems and aqueous solutions at low temperatures. The focus of the dissertation is on the continued development of low temperature biological small angle X-ray scattering (SAXS), cryoSAXS. CryoSAXS is a new method for biological SAXS that involves cryocooling the sample to 100 K. At 100 K the sample is much more resistant to damage from X-rays, enabling use of volumes hundreds or thousands of times smaller than in conventional room temperature SAXS. This work was divided into three main pieces. First, we designed, microfabricated, and tested new small volume, fixed path length sample holder for use in cryoSAXS. Next, as a first step towards answering the question of how much the radiation tolerance of a sample increases upon cryocooling, we developed methods to quantify radiation damage to SAXS profiles and tested these using standard room temperature SAXS. Finally, we measured the radiation tolerance of cryocooled SAXS samples, and found that the cryocooling decreases the radiation sensitivity by three orders of magnitude. The last chapter of the dissertation describes ongoing work to develop time resolved cryoSAXS, and other outstanding questions in cryoSAXS. In addition to cryoSAXS, in a complementary research project we studied ice formation in aqueous solutions. In particular, we quantified the critical warming rate, the warming rate required to prevent ice formation upon warming a vitrified solution. This has particular relevance to biological cryopreservation, as ice formation can irreparably damage cryopreserved samples.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Hopkins, Jesse"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation is based on the study of biological systems and aqueous solutions at low temperatures. The focus of the dissertation is on the continued development of low temperature biological small angle X-ray scattering (SAXS), cryoSAXS. CryoSAXS is a new method for biological SAXS that involves cryocooling the sample to 100 K. At 100 K the sample is much more resistant to damage from X-rays, enabling use of volumes hundreds or thousands of times smaller than in conventional room temperature SAXS. This work was divided into three main pieces. First, we designed, microfabricated, and tested new small volume, fixed path length sample holder for use in cryoSAXS. Next, as a first step towards answering the question of how much the radiation tolerance of a sample increases upon cryocooling, we developed methods to quantify radiation damage to SAXS profiles and tested these using standard room temperature SAXS. Finally, we measured the radiation tolerance of cryocooled SAXS samples, and found that the cryocooling decreases the radiation sensitivity by three orders of magnitude. The last chapter of the dissertation describes ongoing work to develop time resolved cryoSAXS, and other outstanding questions in cryoSAXS. In addition to cryoSAXS, in a complementary research project we studied ice formation in aqueous solutions. In particular, we quantified the critical warming rate, the warming rate required to prevent ice formation upon warming a vitrified solution. This has particular relevance to biological cryopreservation, as ice formation can irreparably damage cryopreserved samples."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development Of Low Temperature Biological Small Angle X-Ray Scattering, Cryosaxs, And Study Of Ice Formation In Aqueous Solutions"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3ed28909-d0df-449d-8fdb-ec60b4c748cf\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development Of Low Temperature Biological Small Angle X-Ray Scattering, Cryosaxs, And Study Of Ice Formation In Aqueous Solutions</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Hopkins, Jesse</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>cryosaxs</Keyword> <Keyword>small-angle x-ray scattering</Keyword> <Keyword>ice formation</Keyword> <Abstract>This dissertation is based on the study of biological systems and aqueous solutions at low temperatures. The focus of the dissertation is on the continued development of low temperature biological small angle X-ray scattering (SAXS), cryoSAXS. CryoSAXS is a new method for biological SAXS that involves cryocooling the sample to 100 K. At 100 K the sample is much more resistant to damage from X-rays, enabling use of volumes hundreds or thousands of times smaller than in conventional room temperature SAXS. This work was divided into three main pieces. First, we designed, microfabricated, and tested new small volume, fixed path length sample holder for use in cryoSAXS. Next, as a first step towards answering the question of how much the radiation tolerance of a sample increases upon cryocooling, we developed methods to quantify radiation damage to SAXS profiles and tested these using standard room temperature SAXS. Finally, we measured the radiation tolerance of cryocooled SAXS samples, and found that the cryocooling decreases the radiation sensitivity by three orders of magnitude. The last chapter of the dissertation describes ongoing work to develop time resolved cryoSAXS, and other outstanding questions in cryoSAXS. In addition to cryoSAXS, in a complementary research project we studied ice formation in aqueous solutions. In particular, we quantified the critical warming rate, the warming rate required to prevent ice formation upon warming a vitrified solution. This has particular relevance to biological cryopreservation, as ice formation can irreparably damage cryopreserved samples.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Hopkins, Jesse"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Thorne,Robert Edward"],"dc:contributor.committeemember":["Sethna,James Patarasp","Shen,Kyle M.","Pollack,Lois"],"dc:creator":["Hopkins, Jesse"],"dc:date.accessioned":["2016-04-04T18:05:30Z"],"dc:date.available":["2021-02-01T07:00:54Z"],"dc:date.issued":["2016-02-01"],"dc:description.abstract":["This dissertation is based on the study of biological systems and aqueous solutions at low temperatures. The focus of the dissertation is on the continued development of low temperature biological small angle X-ray scattering (SAXS), cryoSAXS. CryoSAXS is a new method for biological SAXS that involves cryocooling the sample to 100 K. At 100 K the sample is much more resistant to damage from X-rays, enabling use of volumes hundreds or thousands of times smaller than in conventional room temperature SAXS. This work was divided into three main pieces. First, we designed, microfabricated, and tested new small volume, fixed path length sample holder for use in cryoSAXS. Next, as a first step towards answering the question of how much the radiation tolerance of a sample increases upon cryocooling, we developed methods to quantify radiation damage to SAXS profiles and tested these using standard room temperature SAXS. Finally, we measured the radiation tolerance of cryocooled SAXS samples, and found that the cryocooling decreases the radiation sensitivity by three orders of magnitude. The last chapter of the dissertation describes ongoing work to develop time resolved cryoSAXS, and other outstanding questions in cryoSAXS. In addition to cryoSAXS, in a complementary research project we studied ice formation in aqueous solutions. In particular, we quantified the critical warming rate, the warming rate required to prevent ice formation upon warming a vitrified solution. This has particular relevance to biological cryopreservation, as ice formation can irreparably damage cryopreserved samples."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9597082"],"dc:identifier.uri":["https://hdl.handle.net/1813/43631"],"dc:language.iso":["en_US"],"dc:subject":["cryosaxs","small-angle x-ray scattering","ice formation"],"dc:title":["Development Of Low Temperature Biological Small Angle X-Ray Scattering, Cryosaxs, And Study Of Ice Formation In Aqueous Solutions"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:03Z"}