{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/43642"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/43642","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Interfacing A Nanonis Controller With A Scanning Tunneling Microscope","abstract":"Scanning Tunneling Microscopy is an important tool in the study of condensed matter physics and has been aided by advances in computers. We obtained four Nanonis scanning tunneling microscope controllers to upgrade our current and new microscopes. The Nanonis hardware and software was designed to work with most scanning tunneling and atomic force microscopes. It has the ability to record multiple analog signals, transform and output similar signals, control piezoelectric motors, and monitor tip movement with a real-time operating system to provide necessary tip movements. The upgrade will afford us with more detailed scanning tools without sacrificing speed, as well as bring the benefits of newer hardware and support. We designed and built a software interface to complement the Nanonis hardware by providing a set workflow with new safety checks and to expose the additional functionality with a useful interface that fits our system. The scalable nature of our software will let us add new kinds of spectroscopic mapping that were unavailable to us in our older control system. Our current upgrade allows for more segmented energy ranges for bias spectrography scans to allow us to target areas of interest for more relevant data in less time. We discuss the structure of the underlying software and the hardware functionality and limits.","abstract_html":"Scanning Tunneling Microscopy is an important tool in the study of condensed matter physics and has been aided by advances in computers. We obtained four Nanonis scanning tunneling microscope controllers to upgrade our current and new microscopes. The Nanonis hardware and software was designed to work with most scanning tunneling and atomic force microscopes. It has the ability to record multiple analog signals, transform and output similar signals, control piezoelectric motors, and monitor tip movement with a real-time operating system to provide necessary tip movements. The upgrade will afford us with more detailed scanning tools without sacrificing speed, as well as bring the benefits of newer hardware and support. We designed and built a software interface to complement the Nanonis hardware by providing a set workflow with new safety checks and to expose the additional functionality with a useful interface that fits our system. The scalable nature of our software will let us add new kinds of spectroscopic mapping that were unavailable to us in our older control system. Our current upgrade allows for more segmented energy ranges for bias spectrography scans to allow us to target areas of interest for more relevant data in less time. We discuss the structure of the underlying software and the hardware functionality and limits.","abstract_has_math":false,"creators":["Rodriguez, Justin"],"institution":"Cornell University","degree_name":"M.S., Applied Physics","degree_level":"Master of Science","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kourkoutis,Lena Fitting"],"committee_members":["Davis,James C."],"year":2016,"date_issued":"2016-02-01","date_published":"2016-02-01","updated_at":"2026-11-19T03:19:03Z","subjects":["Scanning Tunneling Microscopy","Nanonis"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597104"],"render_values":[{"text":"9597104","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/43642","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/43642","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F43642","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Kourkoutis,Lena Fitting"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Davis,James C."]},{"key":"dc:creator","label":"Author","values":["Rodriguez, Justin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-04-04T18:05:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-04-04T18:05:35Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-02-01"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Scanning Tunneling Microscopy","Nanonis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597104"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/43642"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3b972fe0-9222-4d3c-bf07-7055f7f1d3e7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Interfacing A Nanonis Controller With A Scanning Tunneling Microscope</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Rodriguez, Justin</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Scanning Tunneling Microscopy</Keyword> <Keyword>Nanonis</Keyword> <Abstract>Scanning Tunneling Microscopy is an important tool in the study of condensed matter physics and has been aided by advances in computers. We obtained four Nanonis scanning tunneling microscope controllers to upgrade our current and new microscopes. The Nanonis hardware and software was designed to work with most scanning tunneling and atomic force microscopes. It has the ability to record multiple analog signals, transform and output similar signals, control piezoelectric motors, and monitor tip movement with a real-time operating system to provide necessary tip movements. The upgrade will afford us with more detailed scanning tools without sacrificing speed, as well as bring the benefits of newer hardware and support. We designed and built a software interface to complement the Nanonis hardware by providing a set workflow with new safety checks and to expose the additional functionality with a useful interface that fits our system. The scalable nature of our software will let us add new kinds of spectroscopic mapping that were unavailable to us in our older control system. Our current upgrade allows for more segmented energy ranges for bias spectrography scans to allow us to target areas of interest for more relevant data in less time. We discuss the structure of the underlying software and the hardware functionality and limits.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Rodriguez, Justin"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Scanning Tunneling Microscopy is an important tool in the study of condensed matter physics and has been aided by advances in computers. We obtained four Nanonis scanning tunneling microscope controllers to upgrade our current and new microscopes. The Nanonis hardware and software was designed to work with most scanning tunneling and atomic force microscopes. It has the ability to record multiple analog signals, transform and output similar signals, control piezoelectric motors, and monitor tip movement with a real-time operating system to provide necessary tip movements. The upgrade will afford us with more detailed scanning tools without sacrificing speed, as well as bring the benefits of newer hardware and support. We designed and built a software interface to complement the Nanonis hardware by providing a set workflow with new safety checks and to expose the additional functionality with a useful interface that fits our system. The scalable nature of our software will let us add new kinds of spectroscopic mapping that were unavailable to us in our older control system. Our current upgrade allows for more segmented energy ranges for bias spectrography scans to allow us to target areas of interest for more relevant data in less time. We discuss the structure of the underlying software and the hardware functionality and limits."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Interfacing A Nanonis Controller With A Scanning Tunneling Microscope"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3b972fe0-9222-4d3c-bf07-7055f7f1d3e7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Interfacing A Nanonis Controller With A Scanning Tunneling Microscope</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Rodriguez, Justin</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Scanning Tunneling Microscopy</Keyword> <Keyword>Nanonis</Keyword> <Abstract>Scanning Tunneling Microscopy is an important tool in the study of condensed matter physics and has been aided by advances in computers. We obtained four Nanonis scanning tunneling microscope controllers to upgrade our current and new microscopes. The Nanonis hardware and software was designed to work with most scanning tunneling and atomic force microscopes. It has the ability to record multiple analog signals, transform and output similar signals, control piezoelectric motors, and monitor tip movement with a real-time operating system to provide necessary tip movements. The upgrade will afford us with more detailed scanning tools without sacrificing speed, as well as bring the benefits of newer hardware and support. We designed and built a software interface to complement the Nanonis hardware by providing a set workflow with new safety checks and to expose the additional functionality with a useful interface that fits our system. The scalable nature of our software will let us add new kinds of spectroscopic mapping that were unavailable to us in our older control system. Our current upgrade allows for more segmented energy ranges for bias spectrography scans to allow us to target areas of interest for more relevant data in less time. We discuss the structure of the underlying software and the hardware functionality and limits.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Rodriguez, Justin"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Kourkoutis,Lena Fitting"],"dc:contributor.committeemember":["Davis,James C."],"dc:creator":["Rodriguez, Justin"],"dc:date.accessioned":["2016-04-04T18:05:35Z"],"dc:date.available":["2016-04-04T18:05:35Z"],"dc:date.issued":["2016-02-01"],"dc:description.abstract":["Scanning Tunneling Microscopy is an important tool in the study of condensed matter physics and has been aided by advances in computers. We obtained four Nanonis scanning tunneling microscope controllers to upgrade our current and new microscopes. The Nanonis hardware and software was designed to work with most scanning tunneling and atomic force microscopes. It has the ability to record multiple analog signals, transform and output similar signals, control piezoelectric motors, and monitor tip movement with a real-time operating system to provide necessary tip movements. The upgrade will afford us with more detailed scanning tools without sacrificing speed, as well as bring the benefits of newer hardware and support. We designed and built a software interface to complement the Nanonis hardware by providing a set workflow with new safety checks and to expose the additional functionality with a useful interface that fits our system. The scalable nature of our software will let us add new kinds of spectroscopic mapping that were unavailable to us in our older control system. Our current upgrade allows for more segmented energy ranges for bias spectrography scans to allow us to target areas of interest for more relevant data in less time. We discuss the structure of the underlying software and the hardware functionality and limits."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9597104"],"dc:identifier.uri":["https://hdl.handle.net/1813/43642"],"dc:language.iso":["en_US"],"dc:subject":["Scanning Tunneling Microscopy","Nanonis"],"dc:title":["Interfacing A Nanonis Controller With A Scanning Tunneling Microscope"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Applied Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:03Z"}