{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/43699"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/43699","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Acoustic Radiation Force Optical Coherence Elastography : Localized Vs. Wide-Area Perturbation – A Comparison","abstract":"Elastography is a method to image the biomechanical properties of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged with a spectral domain optical coherence tomography (SD-OCT) with a center wavelength of 800 nm and a bandwidth of 180 nm at a transverse optical resolution of 8[mu]m. The existing hypothesis which states that localized harmonic excitation in audio frequency regime has potential advantages in terms of a better mechanical resolution over wide area harmonic excitation is tested. Contrary to the hypothesis, experimental results demonstrates that wide area harmonic excitation has better mechanical resolution. Further the characterization of the frequency dependence of mechanical contrast establishes that mechanical contrast improves with increasing excitation frequency.","abstract_html":"Elastography is a method to image the biomechanical properties of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged with a spectral domain optical coherence tomography (SD-OCT) with a center wavelength of 800 nm and a bandwidth of 180 nm at a transverse optical resolution of 8[mu]m. The existing hypothesis which states that localized harmonic excitation in audio frequency regime has potential advantages in terms of a better mechanical resolution over wide area harmonic excitation is tested. Contrary to the hypothesis, experimental results demonstrates that wide area harmonic excitation has better mechanical resolution. Further the characterization of the frequency dependence of mechanical contrast establishes that mechanical contrast improves with increasing excitation frequency.","abstract_has_math":false,"creators":["Chandrasekaran, Sri nivas"],"institution":"Cornell University","degree_name":"M.S., Applied Physics","degree_level":"Master of Science","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Zipfel,Warren R."],"committee_members":["Lindau,Manfred","Adie,Steven Graham"],"year":2016,"date_issued":"2016-02-01","date_published":"2016-02-01","updated_at":"2026-11-19T03:19:03Z","subjects":["Elastography","Acoustic Radiation Force","Optical Coherence Tomography"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597217"],"render_values":[{"text":"9597217","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/43699","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/43699","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F43699","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Zipfel,Warren R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lindau,Manfred","Adie,Steven Graham"]},{"key":"dc:creator","label":"Author","values":["Chandrasekaran, Sri nivas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-04-04T18:06:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-01T07:00:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-02-01"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Elastography","Acoustic Radiation Force","Optical Coherence Tomography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597217"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/43699"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"5264e4b3-fdc0-4677-b0ad-4ffbf32ff48d\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Acoustic Radiation Force Optical Coherence Elastography : Localized Vs. Wide-Area Perturbation – A Comparison</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Chandrasekaran, Sri nivas</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Elastography</Keyword> <Keyword>Acoustic Radiation Force</Keyword> <Keyword>Optical Coherence Tomography</Keyword> <Abstract>Elastography is a method to image the biomechanical properties of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged with a spectral domain optical coherence tomography (SD-OCT) with a center wavelength of 800 nm and a bandwidth of 180 nm at a transverse optical resolution of 8[mu]m. The existing hypothesis which states that localized harmonic excitation in audio frequency regime has potential advantages in terms of a better mechanical resolution over wide area harmonic excitation is tested. Contrary to the hypothesis, experimental results demonstrates that wide area harmonic excitation has better mechanical resolution. Further the characterization of the frequency dependence of mechanical contrast establishes that mechanical contrast improves with increasing excitation frequency.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Chandrasekaran, Sri nivas"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Elastography is a method to image the biomechanical properties of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged with a spectral domain optical coherence tomography (SD-OCT) with a center wavelength of 800 nm and a bandwidth of 180 nm at a transverse optical resolution of 8[mu]m. The existing hypothesis which states that localized harmonic excitation in audio frequency regime has potential advantages in terms of a better mechanical resolution over wide area harmonic excitation is tested. Contrary to the hypothesis, experimental results demonstrates that wide area harmonic excitation has better mechanical resolution. Further the characterization of the frequency dependence of mechanical contrast establishes that mechanical contrast improves with increasing excitation frequency."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Acoustic Radiation Force Optical Coherence Elastography : Localized Vs. Wide-Area Perturbation – A Comparison"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"5264e4b3-fdc0-4677-b0ad-4ffbf32ff48d\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Acoustic Radiation Force Optical Coherence Elastography : Localized Vs. Wide-Area Perturbation – A Comparison</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-02-01</PublicationDate> <Authors> <Author> <DisplayName>Chandrasekaran, Sri nivas</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Elastography</Keyword> <Keyword>Acoustic Radiation Force</Keyword> <Keyword>Optical Coherence Tomography</Keyword> <Abstract>Elastography is a method to image the biomechanical properties of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged with a spectral domain optical coherence tomography (SD-OCT) with a center wavelength of 800 nm and a bandwidth of 180 nm at a transverse optical resolution of 8[mu]m. The existing hypothesis which states that localized harmonic excitation in audio frequency regime has potential advantages in terms of a better mechanical resolution over wide area harmonic excitation is tested. Contrary to the hypothesis, experimental results demonstrates that wide area harmonic excitation has better mechanical resolution. Further the characterization of the frequency dependence of mechanical contrast establishes that mechanical contrast improves with increasing excitation frequency.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Chandrasekaran, Sri nivas"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Zipfel,Warren R."],"dc:contributor.committeemember":["Lindau,Manfred","Adie,Steven Graham"],"dc:creator":["Chandrasekaran, Sri nivas"],"dc:date.accessioned":["2016-04-04T18:06:06Z"],"dc:date.available":["2021-02-01T07:00:34Z"],"dc:date.issued":["2016-02-01"],"dc:description.abstract":["Elastography is a method to image the biomechanical properties of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged with a spectral domain optical coherence tomography (SD-OCT) with a center wavelength of 800 nm and a bandwidth of 180 nm at a transverse optical resolution of 8[mu]m. The existing hypothesis which states that localized harmonic excitation in audio frequency regime has potential advantages in terms of a better mechanical resolution over wide area harmonic excitation is tested. Contrary to the hypothesis, experimental results demonstrates that wide area harmonic excitation has better mechanical resolution. Further the characterization of the frequency dependence of mechanical contrast establishes that mechanical contrast improves with increasing excitation frequency."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9597217"],"dc:identifier.uri":["https://hdl.handle.net/1813/43699"],"dc:language.iso":["en_US"],"dc:subject":["Elastography","Acoustic Radiation Force","Optical Coherence Tomography"],"dc:title":["Acoustic Radiation Force Optical Coherence Elastography : Localized Vs. Wide-Area Perturbation – A Comparison"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Applied Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:03Z"}