{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/44320"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/44320","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Development Of A Compact Optical Rapid Diagnostic Test Reader And A Point-Of-Care Fluorescence Lateral Flow Assay For Dengue Detection","abstract":"As the prevalence of febrile illnesses continues to increase, there is a growing need for reliable, low-cost means of diagnosing these diseases. To address this, a highly sensitive point-of-care fluorescence lateral flow immunoassay is being developed to diagnose dengue in its earliest stages. Through use of different fluorescent labels, multiplexed test strips will eventually be created to test for several diseases simultaneously. To quantify the resulting signals produced by the assay, a corresponding optical reader was designed, built, and tested in accordance with design thinking principles. The effectiveness of the design was verified through usability testing. The reader works in conjunction with software run on any internet-enabled device to take an image of a test strip and analyze the signal levels by comparing them to predetermined calibration curves. Through use of the fluorescence lateral flow immunoassay and corresponding optical reader, users in resource-limited settings can diagnose dengue rapidly and accurately.","abstract_html":"As the prevalence of febrile illnesses continues to increase, there is a growing need for reliable, low-cost means of diagnosing these diseases. To address this, a highly sensitive point-of-care fluorescence lateral flow immunoassay is being developed to diagnose dengue in its earliest stages. Through use of different fluorescent labels, multiplexed test strips will eventually be created to test for several diseases simultaneously. To quantify the resulting signals produced by the assay, a corresponding optical reader was designed, built, and tested in accordance with design thinking principles. The effectiveness of the design was verified through usability testing. The reader works in conjunction with software run on any internet-enabled device to take an image of a test strip and analyze the signal levels by comparing them to predetermined calibration curves. Through use of the fluorescence lateral flow immunoassay and corresponding optical reader, users in resource-limited settings can diagnose dengue rapidly and accurately.","abstract_has_math":false,"creators":["Hohenstein, Jessica"],"institution":"Cornell University","degree_name":"M.S., Mechanical Engineering","degree_level":"Master of Science","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Erickson,David"],"committee_members":["Gay,Geraldine K"],"year":2016,"date_issued":"2016-05-29","date_published":"2016-05-29","updated_at":"2026-11-19T03:19:03Z","subjects":["Design","Lateral Flow Assay","Rapid Diagnostic Test"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X4TB14TZ"],"render_values":[{"text":"https://doi.org/10.7298/X4TB14TZ","href":"https://doi.org/10.7298/X4TB14TZ","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597114"],"render_values":[{"text":"9597114","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/44320","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/44320","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F44320","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Erickson,David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gay,Geraldine K"]},{"key":"dc:creator","label":"Author","values":["Hohenstein, Jessica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-07-05T15:30:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-05-30T06:00:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-05-29"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Design","Lateral Flow Assay","Rapid Diagnostic Test"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9597114"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X4TB14TZ"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/44320"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"25252d9e-c1cf-472f-9871-904c8184d834\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development Of A Compact Optical Rapid Diagnostic Test Reader And A Point-Of-Care Fluorescence Lateral Flow Assay For Dengue Detection</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-05-29</PublicationDate> <DOI>https://doi.org/10.7298/X4TB14TZ</DOI> <Authors> <Author> <DisplayName>Hohenstein, Jessica</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Design</Keyword> <Keyword>Lateral Flow Assay</Keyword> <Keyword>Rapid Diagnostic Test</Keyword> <Abstract>As the prevalence of febrile illnesses continues to increase, there is a growing need for reliable, low-cost means of diagnosing these diseases. To address this, a highly sensitive point-of-care fluorescence lateral flow immunoassay is being developed to diagnose dengue in its earliest stages. Through use of different fluorescent labels, multiplexed test strips will eventually be created to test for several diseases simultaneously. To quantify the resulting signals produced by the assay, a corresponding optical reader was designed, built, and tested in accordance with design thinking principles. The effectiveness of the design was verified through usability testing. The reader works in conjunction with software run on any internet-enabled device to take an image of a test strip and analyze the signal levels by comparing them to predetermined calibration curves. Through use of the fluorescence lateral flow immunoassay and corresponding optical reader, users in resource-limited settings can diagnose dengue rapidly and accurately.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Hohenstein, Jessica"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["As the prevalence of febrile illnesses continues to increase, there is a growing need for reliable, low-cost means of diagnosing these diseases. To address this, a highly sensitive point-of-care fluorescence lateral flow immunoassay is being developed to diagnose dengue in its earliest stages. Through use of different fluorescent labels, multiplexed test strips will eventually be created to test for several diseases simultaneously. To quantify the resulting signals produced by the assay, a corresponding optical reader was designed, built, and tested in accordance with design thinking principles. The effectiveness of the design was verified through usability testing. The reader works in conjunction with software run on any internet-enabled device to take an image of a test strip and analyze the signal levels by comparing them to predetermined calibration curves. Through use of the fluorescence lateral flow immunoassay and corresponding optical reader, users in resource-limited settings can diagnose dengue rapidly and accurately."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development Of A Compact Optical Rapid Diagnostic Test Reader And A Point-Of-Care Fluorescence Lateral Flow Assay For Dengue Detection"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"25252d9e-c1cf-472f-9871-904c8184d834\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development Of A Compact Optical Rapid Diagnostic Test Reader And A Point-Of-Care Fluorescence Lateral Flow Assay For Dengue Detection</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2016-05-29</PublicationDate> <DOI>https://doi.org/10.7298/X4TB14TZ</DOI> <Authors> <Author> <DisplayName>Hohenstein, Jessica</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Design</Keyword> <Keyword>Lateral Flow Assay</Keyword> <Keyword>Rapid Diagnostic Test</Keyword> <Abstract>As the prevalence of febrile illnesses continues to increase, there is a growing need for reliable, low-cost means of diagnosing these diseases. To address this, a highly sensitive point-of-care fluorescence lateral flow immunoassay is being developed to diagnose dengue in its earliest stages. Through use of different fluorescent labels, multiplexed test strips will eventually be created to test for several diseases simultaneously. To quantify the resulting signals produced by the assay, a corresponding optical reader was designed, built, and tested in accordance with design thinking principles. The effectiveness of the design was verified through usability testing. The reader works in conjunction with software run on any internet-enabled device to take an image of a test strip and analyze the signal levels by comparing them to predetermined calibration curves. Through use of the fluorescence lateral flow immunoassay and corresponding optical reader, users in resource-limited settings can diagnose dengue rapidly and accurately.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Hohenstein, Jessica"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Erickson,David"],"dc:contributor.committeemember":["Gay,Geraldine K"],"dc:creator":["Hohenstein, Jessica"],"dc:date.accessioned":["2016-07-05T15:30:06Z"],"dc:date.available":["2021-05-30T06:00:29Z"],"dc:date.issued":["2016-05-29"],"dc:description.abstract":["As the prevalence of febrile illnesses continues to increase, there is a growing need for reliable, low-cost means of diagnosing these diseases. To address this, a highly sensitive point-of-care fluorescence lateral flow immunoassay is being developed to diagnose dengue in its earliest stages. Through use of different fluorescent labels, multiplexed test strips will eventually be created to test for several diseases simultaneously. To quantify the resulting signals produced by the assay, a corresponding optical reader was designed, built, and tested in accordance with design thinking principles. The effectiveness of the design was verified through usability testing. The reader works in conjunction with software run on any internet-enabled device to take an image of a test strip and analyze the signal levels by comparing them to predetermined calibration curves. Through use of the fluorescence lateral flow immunoassay and corresponding optical reader, users in resource-limited settings can diagnose dengue rapidly and accurately."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9597114"],"dc:identifier.doi":["https://doi.org/10.7298/X4TB14TZ"],"dc:identifier.uri":["https://hdl.handle.net/1813/44320"],"dc:language.iso":["en_US"],"dc:subject":["Design","Lateral Flow Assay","Rapid Diagnostic Test"],"dc:title":["Development Of A Compact Optical Rapid Diagnostic Test Reader And A Point-Of-Care Fluorescence Lateral Flow Assay For Dengue Detection"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:03Z"}