{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/47906"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/47906","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"REMOVAL OF MICROPOLLUTANTS IN BIOFILTERS: HYDRODYNAMIC EFFECTS ON BIOTRANSFORMATION RATES","abstract":"Global water resources contain a variety of organic chemicals, including pharmaceuticals, personal care products, and pesticides at trace concentrations. This study investigated the application of biofiltration for the removal of these so-called micropollutants from drinking water resources. The objective of this work was to examine how hydrodynamics influence biotransformation rates in biofiltration processes. Measurements included biomass concentration, depths of the biological zone, and removal rates of 29 micropollutants at environmentally-relevant concentrations in bench-scale biofiltration columns operated under three distinct hydrodynamic regimes. Higher superficial velocities led to less concentrated surface biomass but a deeper biological zone and more total biomass. Eleven micropollutants underwent biotic removal and second-order rate constants were not significantly different between hydrodynamic regimes for each micropollutant. Of these micropollutants, five had significantly greater second-order rate constants at deeper biofilter depths. This work is an important step in improving our understanding of how hydrodynamics influence drinking water biofiltration performance.","abstract_html":"Global water resources contain a variety of organic chemicals, including pharmaceuticals, personal care products, and pesticides at trace concentrations. This study investigated the application of biofiltration for the removal of these so-called micropollutants from drinking water resources. The objective of this work was to examine how hydrodynamics influence biotransformation rates in biofiltration processes. Measurements included biomass concentration, depths of the biological zone, and removal rates of 29 micropollutants at environmentally-relevant concentrations in bench-scale biofiltration columns operated under three distinct hydrodynamic regimes. Higher superficial velocities led to less concentrated surface biomass but a deeper biological zone and more total biomass. Eleven micropollutants underwent biotic removal and second-order rate constants were not significantly different between hydrodynamic regimes for each micropollutant. Of these micropollutants, five had significantly greater second-order rate constants at deeper biofilter depths. This work is an important step in improving our understanding of how hydrodynamics influence drinking water biofiltration performance.","abstract_has_math":false,"creators":["Carpenter, Corey"],"institution":"Cornell University","degree_name":"M.S., Civil and Environmental Engineering","degree_level":"Master of Science","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Helbling, Damian E"],"committee_members":["Weber-Shirk, Monroe","Richardson, Ruth E."],"year":2017,"date_issued":"2017-01-30","date_published":"2017-01-30","updated_at":"2026-11-19T03:19:15Z","subjects":["Environmental engineering","Biofiltration","Micropollutants","Trace organic contaminants"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X45B00DN"],"render_values":[{"text":"https://doi.org/10.7298/X45B00DN","href":"https://doi.org/10.7298/X45B00DN","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9906153"],"render_values":[{"text":"9906153","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10018","ProQuest Publication ID: 10246696"],"render_values":[{"text":"ProQuest Submission ID: 10018","href":null,"code":true},{"text":"ProQuest Publication ID: 10246696","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/47906","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/47906","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F47906","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Helbling, Damian E"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Weber-Shirk, Monroe","Richardson, Ruth E."]},{"key":"dc:creator","label":"Author","values":["Carpenter, Corey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-04-04T20:28:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-12-08T07:00:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-01-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Civil and Environmental Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Environmental engineering","Biofiltration","Micropollutants","Trace organic contaminants"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["9906153"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X45B00DN"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10018","ProQuest Publication ID: 10246696"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/47906"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4e8a3f5b-f7b4-4d5c-9ad0-d23f6ce73705\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>REMOVAL OF MICROPOLLUTANTS IN BIOFILTERS: HYDRODYNAMIC EFFECTS ON BIOTRANSFORMATION RATES</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-01-30</PublicationDate> <DOI>https://doi.org/10.7298/X45B00DN</DOI> <Authors> <Author> <DisplayName>Carpenter, Corey</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Environmental engineering</Keyword> <Keyword>Biofiltration</Keyword> <Keyword>Micropollutants</Keyword> <Keyword>Trace organic contaminants</Keyword> <Abstract>Global water resources contain a variety of organic chemicals, including pharmaceuticals, personal care products, and pesticides at trace concentrations. This study investigated the application of biofiltration for the removal of these so-called micropollutants from drinking water resources. The objective of this work was to examine how hydrodynamics influence biotransformation rates in biofiltration processes. Measurements included biomass concentration, depths of the biological zone, and removal rates of 29 micropollutants at environmentally-relevant concentrations in bench-scale biofiltration columns operated under three distinct hydrodynamic regimes. Higher superficial velocities led to less concentrated surface biomass but a deeper biological zone and more total biomass. Eleven micropollutants underwent biotic removal and second-order rate constants were not significantly different between hydrodynamic regimes for each micropollutant. Of these micropollutants, five had significantly greater second-order rate constants at deeper biofilter depths. This work is an important step in improving our understanding of how hydrodynamics influence drinking water biofiltration performance.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Carpenter, Corey"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Global water resources contain a variety of organic chemicals, including pharmaceuticals, personal care products, and pesticides at trace concentrations. This study investigated the application of biofiltration for the removal of these so-called micropollutants from drinking water resources. The objective of this work was to examine how hydrodynamics influence biotransformation rates in biofiltration processes. Measurements included biomass concentration, depths of the biological zone, and removal rates of 29 micropollutants at environmentally-relevant concentrations in bench-scale biofiltration columns operated under three distinct hydrodynamic regimes. Higher superficial velocities led to less concentrated surface biomass but a deeper biological zone and more total biomass. Eleven micropollutants underwent biotic removal and second-order rate constants were not significantly different between hydrodynamic regimes for each micropollutant. Of these micropollutants, five had significantly greater second-order rate constants at deeper biofilter depths. This work is an important step in improving our understanding of how hydrodynamics influence drinking water biofiltration performance."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["REMOVAL OF MICROPOLLUTANTS IN BIOFILTERS: HYDRODYNAMIC EFFECTS ON BIOTRANSFORMATION RATES"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4e8a3f5b-f7b4-4d5c-9ad0-d23f6ce73705\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>REMOVAL OF MICROPOLLUTANTS IN BIOFILTERS: HYDRODYNAMIC EFFECTS ON BIOTRANSFORMATION RATES</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-01-30</PublicationDate> <DOI>https://doi.org/10.7298/X45B00DN</DOI> <Authors> <Author> <DisplayName>Carpenter, Corey</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Environmental engineering</Keyword> <Keyword>Biofiltration</Keyword> <Keyword>Micropollutants</Keyword> <Keyword>Trace organic contaminants</Keyword> <Abstract>Global water resources contain a variety of organic chemicals, including pharmaceuticals, personal care products, and pesticides at trace concentrations. This study investigated the application of biofiltration for the removal of these so-called micropollutants from drinking water resources. The objective of this work was to examine how hydrodynamics influence biotransformation rates in biofiltration processes. Measurements included biomass concentration, depths of the biological zone, and removal rates of 29 micropollutants at environmentally-relevant concentrations in bench-scale biofiltration columns operated under three distinct hydrodynamic regimes. Higher superficial velocities led to less concentrated surface biomass but a deeper biological zone and more total biomass. Eleven micropollutants underwent biotic removal and second-order rate constants were not significantly different between hydrodynamic regimes for each micropollutant. Of these micropollutants, five had significantly greater second-order rate constants at deeper biofilter depths. This work is an important step in improving our understanding of how hydrodynamics influence drinking water biofiltration performance.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Carpenter, Corey"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Helbling, Damian E"],"dc:contributor.committeemember":["Weber-Shirk, Monroe","Richardson, Ruth E."],"dc:creator":["Carpenter, Corey"],"dc:date.accessioned":["2017-04-04T20:28:40Z"],"dc:date.available":["2017-12-08T07:00:33Z"],"dc:date.issued":["2017-01-30"],"dc:description.abstract":["Global water resources contain a variety of organic chemicals, including pharmaceuticals, personal care products, and pesticides at trace concentrations. This study investigated the application of biofiltration for the removal of these so-called micropollutants from drinking water resources. The objective of this work was to examine how hydrodynamics influence biotransformation rates in biofiltration processes. Measurements included biomass concentration, depths of the biological zone, and removal rates of 29 micropollutants at environmentally-relevant concentrations in bench-scale biofiltration columns operated under three distinct hydrodynamic regimes. Higher superficial velocities led to less concentrated surface biomass but a deeper biological zone and more total biomass. Eleven micropollutants underwent biotic removal and second-order rate constants were not significantly different between hydrodynamic regimes for each micropollutant. Of these micropollutants, five had significantly greater second-order rate constants at deeper biofilter depths. This work is an important step in improving our understanding of how hydrodynamics influence drinking water biofiltration performance."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["9906153"],"dc:identifier.doi":["https://doi.org/10.7298/X45B00DN"],"dc:identifier.other":["ProQuest Submission ID: 10018","ProQuest Publication ID: 10246696"],"dc:identifier.uri":["https://hdl.handle.net/1813/47906"],"dc:language.iso":["en_US"],"dc:subject":["Environmental engineering","Biofiltration","Micropollutants","Trace organic contaminants"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["REMOVAL OF MICROPOLLUTANTS IN BIOFILTERS: HYDRODYNAMIC EFFECTS ON BIOTRANSFORMATION RATES"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Civil and Environmental Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:15Z"}