{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/56734"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/56734","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"For brighter electron sources: a cryogenically cooled photocathode and DC photogun","abstract":"Electron beams produced by photoinjectors have a wide range of applications including colliders for high energy and nuclear physics experiments, Free Electron Lasers (FEL), Energy Recovery Linacs (ERL), and Ultrafast Electron Diffraction (UED) with a variety of uses. These applications have been made possible by recent advancement in photocathode and photoinjector research. The key factor is building a compact high-brightness electron source with high voltage and electric field at the photocathode to maximize the electron emission and minimize emittance growth due to space-charge effect. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. This thesis presents three important results; (i) cryogenically cooled photocathode. From 300K to 90 K, the MTE reduction has been measured from 38±meV to 22 ±1meV. (ii) transmission photocathode. MTEs generated from the photocathode operated in transmission mode is smaller by 20% in comparison with the reflection mode operation, which is accompanied by a corresponding QE decrease of about a factor of 2. (iii) a new design of a DC photoemission gun and beamline constructed at Cornell University, along with demonstration of a cryogenically cooled photocathode and transmission photocathode. This photoemission gun can operate at ~200kV at both room temperature (RT) and cryogenic temperature (low T) with a corresponding electric field of 10MV/m.","abstract_html":"Electron beams produced by photoinjectors have a wide range of applications including colliders for high energy and nuclear physics experiments, Free Electron Lasers (FEL), Energy Recovery Linacs (ERL), and Ultrafast Electron Diffraction (UED) with a variety of uses. These applications have been made possible by recent advancement in photocathode and photoinjector research. The key factor is building a compact high-brightness electron source with high voltage and electric field at the photocathode to maximize the electron emission and minimize emittance growth due to space-charge effect. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. This thesis presents three important results; (i) cryogenically cooled photocathode. From 300K to 90 K, the MTE reduction has been measured from 38±meV to 22 ±1meV. (ii) transmission photocathode. MTEs generated from the photocathode operated in transmission mode is smaller by 20% in comparison with the reflection mode operation, which is accompanied by a corresponding QE decrease of about a factor of 2. (iii) a new design of a DC photoemission gun and beamline constructed at Cornell University, along with demonstration of a cryogenically cooled photocathode and transmission photocathode. This photoemission gun can operate at ~200kV at both room temperature (RT) and cryogenic temperature (low T) with a corresponding electric field of 10MV/m.","abstract_has_math":false,"creators":["Lee, Hyeri"],"institution":"Cornell University","degree_name":"Ph. D., Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Bazarov, Ivan"],"committee_members":["Kourkoutis, Lena Fitting","Dunham, Bruce Matthew","Sethna, James Patarasp"],"year":2017,"date_issued":"2017-08-30","date_published":"2017-08-30","updated_at":"2026-11-19T03:19:41Z","subjects":["Physics","bright electron beam","cryogenic cathode","photoemission","photoemission gun","transmission cathode","ultrafast electron diffraction"],"languages":["en_US"],"rights":["Attribution-NoDerivatives 2.0 Generic"],"rights_urls":["https://creativecommons.org/licenses/by-nd/2.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X41R6NP8"],"render_values":[{"text":"https://doi.org/10.7298/X41R6NP8","href":"https://doi.org/10.7298/X41R6NP8","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361411"],"render_values":[{"text":"10361411","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10333","ProQuest Publication ID: 10598859"],"render_values":[{"text":"ProQuest Submission ID: 10333","href":null,"code":true},{"text":"ProQuest Publication ID: 10598859","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/56734","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/56734","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F56734","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Bazarov, Ivan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kourkoutis, Lena Fitting","Dunham, Bruce Matthew","Sethna, James Patarasp"]},{"key":"dc:creator","label":"Author","values":["Lee, Hyeri"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-04-26T14:15:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-04-26T14:15:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","bright electron beam","cryogenic cathode","photoemission","photoemission gun","transmission cathode","ultrafast electron diffraction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivatives 2.0 Generic"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nd/2.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361411"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X41R6NP8"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10333","ProQuest Publication ID: 10598859"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/56734"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"5467e628-b138-41eb-99e9-6521f061038b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>For brighter electron sources: a cryogenically cooled photocathode and DC photogun</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X41R6NP8</DOI> <Authors> <Author> <DisplayName>Lee, Hyeri</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nd/2.0/</License> <Keyword>Physics</Keyword> <Keyword>bright electron beam</Keyword> <Keyword>cryogenic cathode</Keyword> <Keyword>photoemission</Keyword> <Keyword>photoemission gun</Keyword> <Keyword>transmission cathode</Keyword> <Keyword>ultrafast electron diffraction</Keyword> <Abstract>Electron beams produced by photoinjectors have a wide range of applications including colliders for high energy and nuclear physics experiments, Free Electron Lasers (FEL), Energy Recovery Linacs (ERL), and Ultrafast Electron Diffraction (UED) with a variety of uses. These applications have been made possible by recent advancement in photocathode and photoinjector research. The key factor is building a compact high-brightness electron source with high voltage and electric field at the photocathode to maximize the electron emission and minimize emittance growth due to space-charge effect. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. This thesis presents three important results; (i) cryogenically cooled photocathode. From 300K to 90 K, the MTE reduction has been measured from 38±meV to 22 ±1meV. (ii) transmission photocathode. MTEs generated from the photocathode operated in transmission mode is smaller by 20% in comparison with the reflection mode operation, which is accompanied by a corresponding QE decrease of about a factor of 2. (iii) a new design of a DC photoemission gun and beamline constructed at Cornell University, along with demonstration of a cryogenically cooled photocathode and transmission photocathode. This photoemission gun can operate at ~200kV at both room temperature (RT) and cryogenic temperature (low T) with a corresponding electric field of 10MV/m.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Lee, Hyeri"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Electron beams produced by photoinjectors have a wide range of applications including colliders for high energy and nuclear physics experiments, Free Electron Lasers (FEL), Energy Recovery Linacs (ERL), and Ultrafast Electron Diffraction (UED) with a variety of uses. These applications have been made possible by recent advancement in photocathode and photoinjector research. The key factor is building a compact high-brightness electron source with high voltage and electric field at the photocathode to maximize the electron emission and minimize emittance growth due to space-charge effect. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. This thesis presents three important results; (i) cryogenically cooled photocathode. From 300K to 90 K, the MTE reduction has been measured from 38±meV to 22 ±1meV. (ii) transmission photocathode. MTEs generated from the photocathode operated in transmission mode is smaller by 20% in comparison with the reflection mode operation, which is accompanied by a corresponding QE decrease of about a factor of 2. (iii) a new design of a DC photoemission gun and beamline constructed at Cornell University, along with demonstration of a cryogenically cooled photocathode and transmission photocathode. This photoemission gun can operate at ~200kV at both room temperature (RT) and cryogenic temperature (low T) with a corresponding electric field of 10MV/m."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["For brighter electron sources: a cryogenically cooled photocathode and DC photogun"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"5467e628-b138-41eb-99e9-6521f061038b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>For brighter electron sources: a cryogenically cooled photocathode and DC photogun</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X41R6NP8</DOI> <Authors> <Author> <DisplayName>Lee, Hyeri</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nd/2.0/</License> <Keyword>Physics</Keyword> <Keyword>bright electron beam</Keyword> <Keyword>cryogenic cathode</Keyword> <Keyword>photoemission</Keyword> <Keyword>photoemission gun</Keyword> <Keyword>transmission cathode</Keyword> <Keyword>ultrafast electron diffraction</Keyword> <Abstract>Electron beams produced by photoinjectors have a wide range of applications including colliders for high energy and nuclear physics experiments, Free Electron Lasers (FEL), Energy Recovery Linacs (ERL), and Ultrafast Electron Diffraction (UED) with a variety of uses. These applications have been made possible by recent advancement in photocathode and photoinjector research. The key factor is building a compact high-brightness electron source with high voltage and electric field at the photocathode to maximize the electron emission and minimize emittance growth due to space-charge effect. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. This thesis presents three important results; (i) cryogenically cooled photocathode. From 300K to 90 K, the MTE reduction has been measured from 38±meV to 22 ±1meV. (ii) transmission photocathode. MTEs generated from the photocathode operated in transmission mode is smaller by 20% in comparison with the reflection mode operation, which is accompanied by a corresponding QE decrease of about a factor of 2. (iii) a new design of a DC photoemission gun and beamline constructed at Cornell University, along with demonstration of a cryogenically cooled photocathode and transmission photocathode. This photoemission gun can operate at ~200kV at both room temperature (RT) and cryogenic temperature (low T) with a corresponding electric field of 10MV/m.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Lee, Hyeri"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Bazarov, Ivan"],"dc:contributor.committeemember":["Kourkoutis, Lena Fitting","Dunham, Bruce Matthew","Sethna, James Patarasp"],"dc:creator":["Lee, Hyeri"],"dc:date.accessioned":["2018-04-26T14:15:46Z"],"dc:date.available":["2018-04-26T14:15:46Z"],"dc:date.issued":["2017-08-30"],"dc:description.abstract":["Electron beams produced by photoinjectors have a wide range of applications including colliders for high energy and nuclear physics experiments, Free Electron Lasers (FEL), Energy Recovery Linacs (ERL), and Ultrafast Electron Diffraction (UED) with a variety of uses. These applications have been made possible by recent advancement in photocathode and photoinjector research. The key factor is building a compact high-brightness electron source with high voltage and electric field at the photocathode to maximize the electron emission and minimize emittance growth due to space-charge effect. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. This thesis presents three important results; (i) cryogenically cooled photocathode. From 300K to 90 K, the MTE reduction has been measured from 38±meV to 22 ±1meV. (ii) transmission photocathode. MTEs generated from the photocathode operated in transmission mode is smaller by 20% in comparison with the reflection mode operation, which is accompanied by a corresponding QE decrease of about a factor of 2. (iii) a new design of a DC photoemission gun and beamline constructed at Cornell University, along with demonstration of a cryogenically cooled photocathode and transmission photocathode. This photoemission gun can operate at ~200kV at both room temperature (RT) and cryogenic temperature (low T) with a corresponding electric field of 10MV/m."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["10361411"],"dc:identifier.doi":["https://doi.org/10.7298/X41R6NP8"],"dc:identifier.other":["ProQuest Submission ID: 10333","ProQuest Publication ID: 10598859"],"dc:identifier.uri":["https://hdl.handle.net/1813/56734"],"dc:language.iso":["en_US"],"dc:rights":["Attribution-NoDerivatives 2.0 Generic"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nd/2.0/"],"dc:subject":["Physics","bright electron beam","cryogenic cathode","photoemission","photoemission gun","transmission cathode","ultrafast electron diffraction"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["For brighter electron sources: a cryogenically cooled photocathode and DC photogun"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:41Z"}