{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/56784"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/56784","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES","abstract":"Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process.","abstract_html":"Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process.","abstract_has_math":false,"creators":["Xie, Yiting"],"institution":"Cornell University","degree_name":"Ph. D., Electrical and Computer Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Reeves, Anthony P."],"committee_members":["Chen, Tsuhan","Snavely, Keith Noah"],"year":2017,"date_issued":"2017-08-30","date_published":"2017-08-30","updated_at":"2026-11-19T03:19:41Z","subjects":["Electrical engineering","Cardiac and lung biomarkers","Computer analysis of medical images","Fully-automated CAD","Low-dose CT images","Computer science","Biomedical engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X4GF0RP5"],"render_values":[{"text":"https://doi.org/10.7298/X4GF0RP5","href":"https://doi.org/10.7298/X4GF0RP5","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361461"],"render_values":[{"text":"10361461","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10366","ProQuest Publication ID: 10603875"],"render_values":[{"text":"ProQuest Submission ID: 10366","href":null,"code":true},{"text":"ProQuest Publication ID: 10603875","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/56784","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/56784","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F56784","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Reeves, Anthony P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Chen, Tsuhan","Snavely, Keith Noah"]},{"key":"dc:creator","label":"Author","values":["Xie, Yiting"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-04-26T14:16:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-09-11T06:01:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Electrical and Computer Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering","Cardiac and lung biomarkers","Computer analysis of medical images","Fully-automated CAD","Low-dose CT images","Computer science","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361461"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X4GF0RP5"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10366","ProQuest Publication ID: 10603875"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/56784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"95692f51-6e28-4b8f-91b6-c991f3b0ece7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X4GF0RP5</DOI> <Authors> <Author> <DisplayName>Xie, Yiting</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Electrical engineering</Keyword> <Keyword>Cardiac and lung biomarkers</Keyword> <Keyword>Computer analysis of medical images</Keyword> <Keyword>Fully-automated CAD</Keyword> <Keyword>Low-dose CT images</Keyword> <Keyword>Computer science</Keyword> <Keyword>Biomedical engineering</Keyword> <Abstract>Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Xie, Yiting"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"95692f51-6e28-4b8f-91b6-c991f3b0ece7\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X4GF0RP5</DOI> <Authors> <Author> <DisplayName>Xie, Yiting</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Electrical engineering</Keyword> <Keyword>Cardiac and lung biomarkers</Keyword> <Keyword>Computer analysis of medical images</Keyword> <Keyword>Fully-automated CAD</Keyword> <Keyword>Low-dose CT images</Keyword> <Keyword>Computer science</Keyword> <Keyword>Biomedical engineering</Keyword> <Abstract>Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Xie, Yiting"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Reeves, Anthony P."],"dc:contributor.committeemember":["Chen, Tsuhan","Snavely, Keith Noah"],"dc:creator":["Xie, Yiting"],"dc:date.accessioned":["2018-04-26T14:16:15Z"],"dc:date.available":["2018-09-11T06:01:06Z"],"dc:date.issued":["2017-08-30"],"dc:description.abstract":["Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["10361461"],"dc:identifier.doi":["https://doi.org/10.7298/X4GF0RP5"],"dc:identifier.other":["ProQuest Submission ID: 10366","ProQuest Publication ID: 10603875"],"dc:identifier.uri":["https://hdl.handle.net/1813/56784"],"dc:language.iso":["en_US"],"dc:subject":["Electrical engineering","Cardiac and lung biomarkers","Computer analysis of medical images","Fully-automated CAD","Low-dose CT images","Computer science","Biomedical engineering"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Electrical and Computer Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:41Z"}