{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/56814"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/56814","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"STUDY OF EFFECT OF PERSONAL FLOTATION DEVICE ON PERFORMANCE OF ROWERS","abstract":"This study investigated the factors affecting the wearing of PFDs on rowing athletes’ motion and performance. Pre-experiment tests were conducted with 7 elite collegiate rowers. Both quantitative and qualitative data from the pre-test indicated that conventional Type II PFDs have significant restrictions especially in the shoulder and hip joints and were considered along with the prevailing culture of PFD nonuse by rowers. Accompanied with multi-disciplinary knowledge, a new prototype was successfully developed to minimize these restrictions, to improve mobility, comfort, and effectiveness, which was proved by post-development testing with 6 out of 7 rowers from the initial test. Possibilities for further improvements on the prototype have been proposed and preliminary flotation test was conducted to confirm the adequate buoyancy. This study implied the importance of understanding body motion when designing for specific activity. Future studies with larger sample size, field test, and metabolism measurements are expected to provide more in-depth understanding.","abstract_html":"This study investigated the factors affecting the wearing of PFDs on rowing athletes’ motion and performance. Pre-experiment tests were conducted with 7 elite collegiate rowers. Both quantitative and qualitative data from the pre-test indicated that conventional Type II PFDs have significant restrictions especially in the shoulder and hip joints and were considered along with the prevailing culture of PFD nonuse by rowers. Accompanied with multi-disciplinary knowledge, a new prototype was successfully developed to minimize these restrictions, to improve mobility, comfort, and effectiveness, which was proved by post-development testing with 6 out of 7 rowers from the initial test. Possibilities for further improvements on the prototype have been proposed and preliminary flotation test was conducted to confirm the adequate buoyancy. This study implied the importance of understanding body motion when designing for specific activity. Future studies with larger sample size, field test, and metabolism measurements are expected to provide more in-depth understanding.","abstract_has_math":false,"creators":["Li, Manwen"],"institution":"Cornell University","degree_name":"M.A., Fiber Science and Apparel Design","degree_level":"Master of Arts","degree_discipline":"Fiber Science and Apparel Design","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Park, Huiju"],"committee_members":["Ruina, Andy Lee"],"year":2017,"date_issued":"2017-08-30","date_published":"2017-08-30","updated_at":"2026-11-19T03:19:41Z","subjects":["Apparel design","Ergonomic","Functional design","Motion analysis","Protective garment","Sports science","Textile research","Design","Engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X4KP809H"],"render_values":[{"text":"https://doi.org/10.7298/X4KP809H","href":"https://doi.org/10.7298/X4KP809H","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361491"],"render_values":[{"text":"10361491","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10167","ProQuest Publication ID: 10617175"],"render_values":[{"text":"ProQuest Submission ID: 10167","href":null,"code":true},{"text":"ProQuest Publication ID: 10617175","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/56814","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/56814","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F56814","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Park, Huiju"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ruina, Andy Lee"]},{"key":"dc:creator","label":"Author","values":["Li, Manwen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-04-26T14:16:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-04-26T14:16:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fiber Science and Apparel Design"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Arts"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.A., Fiber Science and Apparel Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Apparel design","Ergonomic","Functional design","Motion analysis","Protective garment","Sports science","Textile research","Design","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361491"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X4KP809H"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10167","ProQuest Publication ID: 10617175"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/56814"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4f21698b-4c69-4d03-ab13-43e1b10687fe\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>STUDY OF EFFECT OF PERSONAL FLOTATION DEVICE ON PERFORMANCE OF ROWERS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X4KP809H</DOI> <Authors> <Author> <DisplayName>Li, Manwen</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Apparel design</Keyword> <Keyword>Ergonomic</Keyword> <Keyword>Functional design</Keyword> <Keyword>Motion analysis</Keyword> <Keyword>Protective garment</Keyword> <Keyword>Sports science</Keyword> <Keyword>Textile research</Keyword> <Keyword>Design</Keyword> <Keyword>Engineering</Keyword> <Abstract>This study investigated the factors affecting the wearing of PFDs on rowing athletes’ motion and performance. Pre-experiment tests were conducted with 7 elite collegiate rowers. Both quantitative and qualitative data from the pre-test indicated that conventional Type II PFDs have significant restrictions especially in the shoulder and hip joints and were considered along with the prevailing culture of PFD nonuse by rowers. Accompanied with multi-disciplinary knowledge, a new prototype was successfully developed to minimize these restrictions, to improve mobility, comfort, and effectiveness, which was proved by post-development testing with 6 out of 7 rowers from the initial test. Possibilities for further improvements on the prototype have been proposed and preliminary flotation test was conducted to confirm the adequate buoyancy. This study implied the importance of understanding body motion when designing for specific activity. Future studies with larger sample size, field test, and metabolism measurements are expected to provide more in-depth understanding.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Li, Manwen"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["This study investigated the factors affecting the wearing of PFDs on rowing athletes’ motion and performance. Pre-experiment tests were conducted with 7 elite collegiate rowers. Both quantitative and qualitative data from the pre-test indicated that conventional Type II PFDs have significant restrictions especially in the shoulder and hip joints and were considered along with the prevailing culture of PFD nonuse by rowers. Accompanied with multi-disciplinary knowledge, a new prototype was successfully developed to minimize these restrictions, to improve mobility, comfort, and effectiveness, which was proved by post-development testing with 6 out of 7 rowers from the initial test. Possibilities for further improvements on the prototype have been proposed and preliminary flotation test was conducted to confirm the adequate buoyancy. This study implied the importance of understanding body motion when designing for specific activity. Future studies with larger sample size, field test, and metabolism measurements are expected to provide more in-depth understanding."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["STUDY OF EFFECT OF PERSONAL FLOTATION DEVICE ON PERFORMANCE OF ROWERS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4f21698b-4c69-4d03-ab13-43e1b10687fe\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>STUDY OF EFFECT OF PERSONAL FLOTATION DEVICE ON PERFORMANCE OF ROWERS</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X4KP809H</DOI> <Authors> <Author> <DisplayName>Li, Manwen</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Apparel design</Keyword> <Keyword>Ergonomic</Keyword> <Keyword>Functional design</Keyword> <Keyword>Motion analysis</Keyword> <Keyword>Protective garment</Keyword> <Keyword>Sports science</Keyword> <Keyword>Textile research</Keyword> <Keyword>Design</Keyword> <Keyword>Engineering</Keyword> <Abstract>This study investigated the factors affecting the wearing of PFDs on rowing athletes’ motion and performance. Pre-experiment tests were conducted with 7 elite collegiate rowers. Both quantitative and qualitative data from the pre-test indicated that conventional Type II PFDs have significant restrictions especially in the shoulder and hip joints and were considered along with the prevailing culture of PFD nonuse by rowers. Accompanied with multi-disciplinary knowledge, a new prototype was successfully developed to minimize these restrictions, to improve mobility, comfort, and effectiveness, which was proved by post-development testing with 6 out of 7 rowers from the initial test. Possibilities for further improvements on the prototype have been proposed and preliminary flotation test was conducted to confirm the adequate buoyancy. This study implied the importance of understanding body motion when designing for specific activity. Future studies with larger sample size, field test, and metabolism measurements are expected to provide more in-depth understanding.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Li, Manwen"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Park, Huiju"],"dc:contributor.committeemember":["Ruina, Andy Lee"],"dc:creator":["Li, Manwen"],"dc:date.accessioned":["2018-04-26T14:16:30Z"],"dc:date.available":["2018-04-26T14:16:30Z"],"dc:date.issued":["2017-08-30"],"dc:description.abstract":["This study investigated the factors affecting the wearing of PFDs on rowing athletes’ motion and performance. Pre-experiment tests were conducted with 7 elite collegiate rowers. Both quantitative and qualitative data from the pre-test indicated that conventional Type II PFDs have significant restrictions especially in the shoulder and hip joints and were considered along with the prevailing culture of PFD nonuse by rowers. Accompanied with multi-disciplinary knowledge, a new prototype was successfully developed to minimize these restrictions, to improve mobility, comfort, and effectiveness, which was proved by post-development testing with 6 out of 7 rowers from the initial test. Possibilities for further improvements on the prototype have been proposed and preliminary flotation test was conducted to confirm the adequate buoyancy. This study implied the importance of understanding body motion when designing for specific activity. Future studies with larger sample size, field test, and metabolism measurements are expected to provide more in-depth understanding."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["10361491"],"dc:identifier.doi":["https://doi.org/10.7298/X4KP809H"],"dc:identifier.other":["ProQuest Submission ID: 10167","ProQuest Publication ID: 10617175"],"dc:identifier.uri":["https://hdl.handle.net/1813/56814"],"dc:language.iso":["en_US"],"dc:subject":["Apparel design","Ergonomic","Functional design","Motion analysis","Protective garment","Sports science","Textile research","Design","Engineering"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["STUDY OF EFFECT OF PERSONAL FLOTATION DEVICE ON PERFORMANCE OF ROWERS"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Fiber Science and Apparel Design"],"thesis:degree_level":["Master of Arts"],"thesis:degree_name":["M.A., Fiber Science and Apparel Design"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:41Z"}