{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/56989"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/56989","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates","abstract":"Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system.","abstract_html":"Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system.","abstract_has_math":false,"creators":["Garland, Casey Ann"],"institution":"Cornell University","degree_name":"Ph. D., Civil and Environmental Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Lion, Leonard William"],"committee_members":["Desjardins, Olivier","Cowen, Edwin Alfred, III","Weber-Shirk, Monroe"],"year":2017,"date_issued":"2017-08-30","date_published":"2017-08-30","updated_at":"2026-11-19T03:19:41Z","subjects":["floc blanket","flocculation","sedimentation","water treatment","Environmental engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X48C9TD8"],"render_values":[{"text":"https://doi.org/10.7298/X48C9TD8","href":"https://doi.org/10.7298/X48C9TD8","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361666"],"render_values":[{"text":"10361666","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10372","ProQuest Publication ID: 10605545"],"render_values":[{"text":"ProQuest Submission ID: 10372","href":null,"code":true},{"text":"ProQuest Publication ID: 10605545","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/56989","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/56989","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F56989","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Lion, Leonard William"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Desjardins, Olivier","Cowen, Edwin Alfred, III","Weber-Shirk, Monroe"]},{"key":"dc:creator","label":"Author","values":["Garland, Casey Ann"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-04-26T14:18:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-04-26T14:18:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Civil and Environmental Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["floc blanket","flocculation","sedimentation","water treatment","Environmental engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["10361666"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/X48C9TD8"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10372","ProQuest Publication ID: 10605545"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/56989"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"409eeccc-84ef-4d60-9cb4-60c7320c5dc2\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X48C9TD8</DOI> <Authors> <Author> <DisplayName>Garland, Casey Ann</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>floc blanket</Keyword> <Keyword>flocculation</Keyword> <Keyword>sedimentation</Keyword> <Keyword>water treatment</Keyword> <Keyword>Environmental engineering</Keyword> <Abstract>Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Garland, Casey Ann"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"409eeccc-84ef-4d60-9cb4-60c7320c5dc2\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017-08-30</PublicationDate> <DOI>https://doi.org/10.7298/X48C9TD8</DOI> <Authors> <Author> <DisplayName>Garland, Casey Ann</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>floc blanket</Keyword> <Keyword>flocculation</Keyword> <Keyword>sedimentation</Keyword> <Keyword>water treatment</Keyword> <Keyword>Environmental engineering</Keyword> <Abstract>Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Garland, Casey Ann"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Lion, Leonard William"],"dc:contributor.committeemember":["Desjardins, Olivier","Cowen, Edwin Alfred, III","Weber-Shirk, Monroe"],"dc:creator":["Garland, Casey Ann"],"dc:date.accessioned":["2018-04-26T14:18:09Z"],"dc:date.available":["2018-04-26T14:18:09Z"],"dc:date.issued":["2017-08-30"],"dc:description.abstract":["Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["10361666"],"dc:identifier.doi":["https://doi.org/10.7298/X48C9TD8"],"dc:identifier.other":["ProQuest Submission ID: 10372","ProQuest Publication ID: 10605545"],"dc:identifier.uri":["https://hdl.handle.net/1813/56989"],"dc:language.iso":["en_US"],"dc:subject":["floc blanket","flocculation","sedimentation","water treatment","Environmental engineering"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Civil and Environmental Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:19:41Z"}