{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/67240"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/67240","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"DEVELOPMENT OF A COLLIMATING CHANNEL ARRAY OPTIC FOR 3D MICROSCOPIC X-RAY FLUORESCENCE","abstract":"A novel x-ray collection optic called the Collimating Channel Array (CCA) for high resolution, 3D microscopic x-ray fluorescence (3D-μXRF) microscopy is developed. In material systems where sampling and sectioning is impossible, 3D-μXRF enables nondestructive spatial elemental mapping and spectroscopy for both technologically important and naturally occurring samples. Confocal x-ray fluorescence (CXRF) is one route to achieve 3D-μXRF. However, with current x-ray optics, the resolution of the micro-probe varies with the characteristic fluorescent x-ray energy of the elements present in the sample. CCAs were developed to solve the energy dependent resolution problem. This thesis describes the design, fabrication and characterization of the CCA optics. Additionally, experimental applications of the CCA optics in a CXRF setup at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) are discussed. First, the basic principles governing the theory of operation of CXRF are examined within the context of designing CCA optics. This will also cover the practical design limitations and how that has impacted the iterative improvements implemented from the initial concept through to the current generation of optics. Second, the manufacture of the CCA optics using microfabrication techniques and deep reactive etching (DRIE) is discussed. Two etch experiments: understanding how to compensate for deep etched artifacts and comparing the etching mechanisms between silicon and germanium are presented. X-ray characterization experiments are then used to analyze the performance of the optics. Third, successful experimental applications involving the use of the CCA optics are presented. These are: elemental imaging of a rice bran, elucidating the corrosion mechanisms in via depth resolved confocal x-ray absorption spectroscopy of a 13th century stained glass window from the Paderborn Cathedral in Germany, and elemental mapping to correlate lead deposits and microstructure of an archaeological human bone sample excavated from the Royal Naval Hospital cemetery (ca. A.D. 1793-1822). Finally, adopting CCA microfabrication techniques, details of the development of another new kind of x-ray optic: a platinum/SU-8 bilayer x-ray transmission mirror is introduced. Thus, this thesis will present a blueprint for a microfabricated approach in developing and implementing novel x-ray optics for x-ray beamlines.","abstract_html":"A novel x-ray collection optic called the Collimating Channel Array (CCA) for high resolution, 3D microscopic x-ray fluorescence (3D-μXRF) microscopy is developed. In material systems where sampling and sectioning is impossible, 3D-μXRF enables nondestructive spatial elemental mapping and spectroscopy for both technologically important and naturally occurring samples. Confocal x-ray fluorescence (CXRF) is one route to achieve 3D-μXRF. However, with current x-ray optics, the resolution of the micro-probe varies with the characteristic fluorescent x-ray energy of the elements present in the sample. CCAs were developed to solve the energy dependent resolution problem. This thesis describes the design, fabrication and characterization of the CCA optics. Additionally, experimental applications of the CCA optics in a CXRF setup at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) are discussed. First, the basic principles governing the theory of operation of CXRF are examined within the context of designing CCA optics. This will also cover the practical design limitations and how that has impacted the iterative improvements implemented from the initial concept through to the current generation of optics. Second, the manufacture of the CCA optics using microfabrication techniques and deep reactive etching (DRIE) is discussed. Two etch experiments: understanding how to compensate for deep etched artifacts and comparing the etching mechanisms between silicon and germanium are presented. X-ray characterization experiments are then used to analyze the performance of the optics. Third, successful experimental applications involving the use of the CCA optics are presented. These are: elemental imaging of a rice bran, elucidating the corrosion mechanisms in via depth resolved confocal x-ray absorption spectroscopy of a 13th century stained glass window from the Paderborn Cathedral in Germany, and elemental mapping to correlate lead deposits and microstructure of an archaeological human bone sample excavated from the Royal Naval Hospital cemetery (ca. A.D. 1793-1822). Finally, adopting CCA microfabrication techniques, details of the development of another new kind of x-ray optic: a platinum/SU-8 bilayer x-ray transmission mirror is introduced. Thus, this thesis will present a blueprint for a microfabricated approach in developing and implementing novel x-ray optics for x-ray beamlines.","abstract_has_math":false,"creators":["Agyeman-Budu, David Nana"],"institution":"Cornell University","degree_name":"Ph.D., Materials Science and Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Brock, Joel Donald"],"committee_members":["Van Dover, Robert B.","Gruner, Sol Michael","Woll, Arthur R."],"year":2019,"date_issued":"2019-05-30","date_published":"2019-05-30","updated_at":"2026-11-19T03:20:35Z","subjects":["Physics","Materials Science","confocal XRF","cultural heritage","germanium etching","transmission mirrors","x-ray fluorescence","x-ray optics","Nanotechnology"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/79s0-sj38"],"render_values":[{"text":"https://doi.org/10.7298/79s0-sj38","href":"https://doi.org/10.7298/79s0-sj38","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050221"],"render_values":[{"text":"11050221","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11285","ProQuest Publication ID: 13428169"],"render_values":[{"text":"ProQuest Submission ID: 11285","href":null,"code":true},{"text":"ProQuest Publication ID: 13428169","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/67240","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/67240","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F67240","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Brock, Joel Donald"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Van Dover, Robert B.","Gruner, Sol Michael","Woll, Arthur R."]},{"key":"dc:creator","label":"Author","values":["Agyeman-Budu, David Nana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-10-15T15:28:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-05T06:00:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-05-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D., Materials Science and Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Materials Science","confocal XRF","cultural heritage","germanium etching","transmission mirrors","x-ray fluorescence","x-ray optics","Nanotechnology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050221"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/79s0-sj38"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11285","ProQuest Publication ID: 13428169"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/67240"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"24c59886-7ddf-448f-85ad-4ac84b5244b8\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>DEVELOPMENT OF A COLLIMATING CHANNEL ARRAY OPTIC FOR 3D MICROSCOPIC X-RAY FLUORESCENCE</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-05-30</PublicationDate> <DOI>https://doi.org/10.7298/79s0-sj38</DOI> <Authors> <Author> <DisplayName>Agyeman-Budu, David Nana</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Physics</Keyword> <Keyword>Materials Science</Keyword> <Keyword>confocal XRF</Keyword> <Keyword>cultural heritage</Keyword> <Keyword>germanium etching</Keyword> <Keyword>transmission mirrors</Keyword> <Keyword>x-ray fluorescence</Keyword> <Keyword>x-ray optics</Keyword> <Keyword>Nanotechnology</Keyword> <Abstract>A novel x-ray collection optic called the Collimating Channel Array (CCA) for high resolution, 3D microscopic x-ray fluorescence (3D-μXRF) microscopy is developed. In material systems where sampling and sectioning is impossible, 3D-μXRF enables nondestructive spatial elemental mapping and spectroscopy for both technologically important and naturally occurring samples. Confocal x-ray fluorescence (CXRF) is one route to achieve 3D-μXRF. However, with current x-ray optics, the resolution of the micro-probe varies with the characteristic fluorescent x-ray energy of the elements present in the sample. CCAs were developed to solve the energy dependent resolution problem. This thesis describes the design, fabrication and characterization of the CCA optics. Additionally, experimental applications of the CCA optics in a CXRF setup at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) are discussed. First, the basic principles governing the theory of operation of CXRF are examined within the context of designing CCA optics. This will also cover the practical design limitations and how that has impacted the iterative improvements implemented from the initial concept through to the current generation of optics. Second, the manufacture of the CCA optics using microfabrication techniques and deep reactive etching (DRIE) is discussed. Two etch experiments: understanding how to compensate for deep etched artifacts and comparing the etching mechanisms between silicon and germanium are presented. X-ray characterization experiments are then used to analyze the performance of the optics. Third, successful experimental applications involving the use of the CCA optics are presented. These are: elemental imaging of a rice bran, elucidating the corrosion mechanisms in via depth resolved confocal x-ray absorption spectroscopy of a 13th century stained glass window from the Paderborn Cathedral in Germany, and elemental mapping to correlate lead deposits and microstructure of an archaeological human bone sample excavated from the Royal Naval Hospital cemetery (ca. A.D. 1793-1822). Finally, adopting CCA microfabrication techniques, details of the development of another new kind of x-ray optic: a platinum/SU-8 bilayer x-ray transmission mirror is introduced. Thus, this thesis will present a blueprint for a microfabricated approach in developing and implementing novel x-ray optics for x-ray beamlines.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Agyeman-Budu, David Nana"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["A novel x-ray collection optic called the Collimating Channel Array (CCA) for high resolution, 3D microscopic x-ray fluorescence (3D-μXRF) microscopy is developed. In material systems where sampling and sectioning is impossible, 3D-μXRF enables nondestructive spatial elemental mapping and spectroscopy for both technologically important and naturally occurring samples. Confocal x-ray fluorescence (CXRF) is one route to achieve 3D-μXRF. However, with current x-ray optics, the resolution of the micro-probe varies with the characteristic fluorescent x-ray energy of the elements present in the sample. CCAs were developed to solve the energy dependent resolution problem. This thesis describes the design, fabrication and characterization of the CCA optics. Additionally, experimental applications of the CCA optics in a CXRF setup at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) are discussed. First, the basic principles governing the theory of operation of CXRF are examined within the context of designing CCA optics. This will also cover the practical design limitations and how that has impacted the iterative improvements implemented from the initial concept through to the current generation of optics. Second, the manufacture of the CCA optics using microfabrication techniques and deep reactive etching (DRIE) is discussed. Two etch experiments: understanding how to compensate for deep etched artifacts and comparing the etching mechanisms between silicon and germanium are presented. X-ray characterization experiments are then used to analyze the performance of the optics. Third, successful experimental applications involving the use of the CCA optics are presented. These are: elemental imaging of a rice bran, elucidating the corrosion mechanisms in via depth resolved confocal x-ray absorption spectroscopy of a 13th century stained glass window from the Paderborn Cathedral in Germany, and elemental mapping to correlate lead deposits and microstructure of an archaeological human bone sample excavated from the Royal Naval Hospital cemetery (ca. A.D. 1793-1822). Finally, adopting CCA microfabrication techniques, details of the development of another new kind of x-ray optic: a platinum/SU-8 bilayer x-ray transmission mirror is introduced. Thus, this thesis will present a blueprint for a microfabricated approach in developing and implementing novel x-ray optics for x-ray beamlines."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["DEVELOPMENT OF A COLLIMATING CHANNEL ARRAY OPTIC FOR 3D MICROSCOPIC X-RAY FLUORESCENCE"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"24c59886-7ddf-448f-85ad-4ac84b5244b8\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>DEVELOPMENT OF A COLLIMATING CHANNEL ARRAY OPTIC FOR 3D MICROSCOPIC X-RAY FLUORESCENCE</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-05-30</PublicationDate> <DOI>https://doi.org/10.7298/79s0-sj38</DOI> <Authors> <Author> <DisplayName>Agyeman-Budu, David Nana</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Physics</Keyword> <Keyword>Materials Science</Keyword> <Keyword>confocal XRF</Keyword> <Keyword>cultural heritage</Keyword> <Keyword>germanium etching</Keyword> <Keyword>transmission mirrors</Keyword> <Keyword>x-ray fluorescence</Keyword> <Keyword>x-ray optics</Keyword> <Keyword>Nanotechnology</Keyword> <Abstract>A novel x-ray collection optic called the Collimating Channel Array (CCA) for high resolution, 3D microscopic x-ray fluorescence (3D-μXRF) microscopy is developed. In material systems where sampling and sectioning is impossible, 3D-μXRF enables nondestructive spatial elemental mapping and spectroscopy for both technologically important and naturally occurring samples. Confocal x-ray fluorescence (CXRF) is one route to achieve 3D-μXRF. However, with current x-ray optics, the resolution of the micro-probe varies with the characteristic fluorescent x-ray energy of the elements present in the sample. CCAs were developed to solve the energy dependent resolution problem. This thesis describes the design, fabrication and characterization of the CCA optics. Additionally, experimental applications of the CCA optics in a CXRF setup at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) are discussed. First, the basic principles governing the theory of operation of CXRF are examined within the context of designing CCA optics. This will also cover the practical design limitations and how that has impacted the iterative improvements implemented from the initial concept through to the current generation of optics. Second, the manufacture of the CCA optics using microfabrication techniques and deep reactive etching (DRIE) is discussed. Two etch experiments: understanding how to compensate for deep etched artifacts and comparing the etching mechanisms between silicon and germanium are presented. X-ray characterization experiments are then used to analyze the performance of the optics. Third, successful experimental applications involving the use of the CCA optics are presented. These are: elemental imaging of a rice bran, elucidating the corrosion mechanisms in via depth resolved confocal x-ray absorption spectroscopy of a 13th century stained glass window from the Paderborn Cathedral in Germany, and elemental mapping to correlate lead deposits and microstructure of an archaeological human bone sample excavated from the Royal Naval Hospital cemetery (ca. A.D. 1793-1822). Finally, adopting CCA microfabrication techniques, details of the development of another new kind of x-ray optic: a platinum/SU-8 bilayer x-ray transmission mirror is introduced. Thus, this thesis will present a blueprint for a microfabricated approach in developing and implementing novel x-ray optics for x-ray beamlines.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Agyeman-Budu, David Nana"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Brock, Joel Donald"],"dc:contributor.committeemember":["Van Dover, Robert B.","Gruner, Sol Michael","Woll, Arthur R."],"dc:creator":["Agyeman-Budu, David Nana"],"dc:date.accessioned":["2019-10-15T15:28:31Z"],"dc:date.available":["2021-06-05T06:00:34Z"],"dc:date.issued":["2019-05-30"],"dc:description.abstract":["A novel x-ray collection optic called the Collimating Channel Array (CCA) for high resolution, 3D microscopic x-ray fluorescence (3D-μXRF) microscopy is developed. In material systems where sampling and sectioning is impossible, 3D-μXRF enables nondestructive spatial elemental mapping and spectroscopy for both technologically important and naturally occurring samples. Confocal x-ray fluorescence (CXRF) is one route to achieve 3D-μXRF. However, with current x-ray optics, the resolution of the micro-probe varies with the characteristic fluorescent x-ray energy of the elements present in the sample. CCAs were developed to solve the energy dependent resolution problem. This thesis describes the design, fabrication and characterization of the CCA optics. Additionally, experimental applications of the CCA optics in a CXRF setup at the Cornell High Energy Synchrotron Source (CHESS) and the Advanced Photon Source (APS) are discussed. First, the basic principles governing the theory of operation of CXRF are examined within the context of designing CCA optics. This will also cover the practical design limitations and how that has impacted the iterative improvements implemented from the initial concept through to the current generation of optics. Second, the manufacture of the CCA optics using microfabrication techniques and deep reactive etching (DRIE) is discussed. Two etch experiments: understanding how to compensate for deep etched artifacts and comparing the etching mechanisms between silicon and germanium are presented. X-ray characterization experiments are then used to analyze the performance of the optics. Third, successful experimental applications involving the use of the CCA optics are presented. These are: elemental imaging of a rice bran, elucidating the corrosion mechanisms in via depth resolved confocal x-ray absorption spectroscopy of a 13th century stained glass window from the Paderborn Cathedral in Germany, and elemental mapping to correlate lead deposits and microstructure of an archaeological human bone sample excavated from the Royal Naval Hospital cemetery (ca. A.D. 1793-1822). Finally, adopting CCA microfabrication techniques, details of the development of another new kind of x-ray optic: a platinum/SU-8 bilayer x-ray transmission mirror is introduced. Thus, this thesis will present a blueprint for a microfabricated approach in developing and implementing novel x-ray optics for x-ray beamlines."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["11050221"],"dc:identifier.doi":["https://doi.org/10.7298/79s0-sj38"],"dc:identifier.other":["ProQuest Submission ID: 11285","ProQuest Publication ID: 13428169"],"dc:identifier.uri":["https://hdl.handle.net/1813/67240"],"dc:language.iso":["en_US"],"dc:subject":["Physics","Materials Science","confocal XRF","cultural heritage","germanium etching","transmission mirrors","x-ray fluorescence","x-ray optics","Nanotechnology"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["DEVELOPMENT OF A COLLIMATING CHANNEL ARRAY OPTIC FOR 3D MICROSCOPIC X-RAY FLUORESCENCE"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph.D., Materials Science and Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:20:35Z"}