{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/67269"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/67269","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release","abstract":"Neurotransmitters are released to the extracellular space in packages by the fusion of vesicles with the cell membrane, a process known as exocytosis. Modulation of this process is a key target for the treatment of neurogenerative diseases, such as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single vesicle release event (quantal size) and the kinetics of exocytosis. Complementary metal-oxide-semiconductor (CMOS) technologies enable the design and fabrication of devices with hundreds or thousands of planar electrodes and amplifiers integrated on the same chip, offering high throughput measurement of exocytosis from living cells. In this dissertation, the development and application of CMOC IC devices with surface modified structures for electrochemical characterization of live cell exocytosis are introduced. In chapter 2, a surface modified CMOS integrated circuit (IC) is demonstrated for highly parallel amperometry measurement of live chromaffin cells. The surface modified structures with SU-8 microwells fabricated on the chip surface solved the two major issues for on-chip single cell measurement devices, the reliability and the single cell targeting efficiency. The surface modified CMOC IC was able to reliably measure 10-30 cells per time per chip with low noise levels, which was a significant increase in efficiency compared to conventional carbon fiber microelectrode measurement. In chapter 3, the surface modified CMOS IC was used to investigate the working mechanisms of the antidepressant drugs bupropion and citalopram. Bupropion was found to potentiate the quantal size and citalopram to increase the release frequency by increasing the readily releasable pool (RRP) size. In chapter 4, a bidirectional-current measurement CMOS IC was designed to enable on-chip cyclic voltammetry (CV) measurement. The new design was capable of measuring current within the range of ±1.5 nA at 10 kS/s. Finally, an improved CMOS IC for CV measurement is presented in chapter 5. The devices consumed less area for each detector and a sign binary output was implemented to identify the polarity of the output current. The devices were validated with on-chip dopamine injection test and potassium ferricyanide CV measurement.","abstract_html":"Neurotransmitters are released to the extracellular space in packages by the fusion of vesicles with the cell membrane, a process known as exocytosis. Modulation of this process is a key target for the treatment of neurogenerative diseases, such as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single vesicle release event (quantal size) and the kinetics of exocytosis. Complementary metal-oxide-semiconductor (CMOS) technologies enable the design and fabrication of devices with hundreds or thousands of planar electrodes and amplifiers integrated on the same chip, offering high throughput measurement of exocytosis from living cells. In this dissertation, the development and application of CMOC IC devices with surface modified structures for electrochemical characterization of live cell exocytosis are introduced. In chapter 2, a surface modified CMOS integrated circuit (IC) is demonstrated for highly parallel amperometry measurement of live chromaffin cells. The surface modified structures with SU-8 microwells fabricated on the chip surface solved the two major issues for on-chip single cell measurement devices, the reliability and the single cell targeting efficiency. The surface modified CMOC IC was able to reliably measure 10-30 cells per time per chip with low noise levels, which was a significant increase in efficiency compared to conventional carbon fiber microelectrode measurement. In chapter 3, the surface modified CMOS IC was used to investigate the working mechanisms of the antidepressant drugs bupropion and citalopram. Bupropion was found to potentiate the quantal size and citalopram to increase the release frequency by increasing the readily releasable pool (RRP) size. In chapter 4, a bidirectional-current measurement CMOS IC was designed to enable on-chip cyclic voltammetry (CV) measurement. The new design was capable of measuring current within the range of ±1.5 nA at 10 kS/s. Finally, an improved CMOS IC for CV measurement is presented in chapter 5. The devices consumed less area for each detector and a sign binary output was implemented to identify the polarity of the output current. The devices were validated with on-chip dopamine injection test and potassium ferricyanide CV measurement.","abstract_has_math":false,"creators":["Huang, Meng"],"institution":"Cornell University","degree_name":"Ph.D., Materials Science and Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Van Dover, Robert B."],"committee_members":["Lindau, Manfred","Ma, Minglin"],"year":2019,"date_issued":"2019-05-30","date_published":"2019-05-30","updated_at":"2026-11-19T03:20:35Z","subjects":["Chromaffin Cells","Neurotransmitter Release","Biophysics","biosensor","amperometry","CMOS","Materials Science","Integrated Circuit"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/rfp3-fd68"],"render_values":[{"text":"https://doi.org/10.7298/rfp3-fd68","href":"https://doi.org/10.7298/rfp3-fd68","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050251"],"render_values":[{"text":"11050251","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11337","ProQuest Publication ID: 13856338"],"render_values":[{"text":"ProQuest Submission ID: 11337","href":null,"code":true},{"text":"ProQuest Publication ID: 13856338","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/67269","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/67269","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F67269","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Van Dover, Robert B."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lindau, Manfred","Ma, Minglin"]},{"key":"dc:creator","label":"Author","values":["Huang, Meng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-10-15T15:28:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-05T06:00:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-05-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D., Materials Science and Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chromaffin Cells","Neurotransmitter Release","Biophysics","biosensor","amperometry","CMOS","Materials Science","Integrated Circuit"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050251"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/rfp3-fd68"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11337","ProQuest Publication ID: 13856338"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/67269"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"efb792ef-f24e-48ab-99c2-157c61f46590\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-05-30</PublicationDate> <DOI>https://doi.org/10.7298/rfp3-fd68</DOI> <Authors> <Author> <DisplayName>Huang, Meng</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Chromaffin Cells</Keyword> <Keyword>Neurotransmitter Release</Keyword> <Keyword>Biophysics</Keyword> <Keyword>biosensor</Keyword> <Keyword>amperometry</Keyword> <Keyword>CMOS</Keyword> <Keyword>Materials Science</Keyword> <Keyword>Integrated Circuit</Keyword> <Abstract>Neurotransmitters are released to the extracellular space in packages by the fusion of vesicles with the cell membrane, a process known as exocytosis. Modulation of this process is a key target for the treatment of neurogenerative diseases, such as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single vesicle release event (quantal size) and the kinetics of exocytosis. Complementary metal-oxide-semiconductor (CMOS) technologies enable the design and fabrication of devices with hundreds or thousands of planar electrodes and amplifiers integrated on the same chip, offering high throughput measurement of exocytosis from living cells. In this dissertation, the development and application of CMOC IC devices with surface modified structures for electrochemical characterization of live cell exocytosis are introduced. In chapter 2, a surface modified CMOS integrated circuit (IC) is demonstrated for highly parallel amperometry measurement of live chromaffin cells. The surface modified structures with SU-8 microwells fabricated on the chip surface solved the two major issues for on-chip single cell measurement devices, the reliability and the single cell targeting efficiency. The surface modified CMOC IC was able to reliably measure 10-30 cells per time per chip with low noise levels, which was a significant increase in efficiency compared to conventional carbon fiber microelectrode measurement. In chapter 3, the surface modified CMOS IC was used to investigate the working mechanisms of the antidepressant drugs bupropion and citalopram. Bupropion was found to potentiate the quantal size and citalopram to increase the release frequency by increasing the readily releasable pool (RRP) size. In chapter 4, a bidirectional-current measurement CMOS IC was designed to enable on-chip cyclic voltammetry (CV) measurement. The new design was capable of measuring current within the range of ±1.5 nA at 10 kS/s. Finally, an improved CMOS IC for CV measurement is presented in chapter 5. The devices consumed less area for each detector and a sign binary output was implemented to identify the polarity of the output current. The devices were validated with on-chip dopamine injection test and potassium ferricyanide CV measurement.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Huang, Meng"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Neurotransmitters are released to the extracellular space in packages by the fusion of vesicles with the cell membrane, a process known as exocytosis. Modulation of this process is a key target for the treatment of neurogenerative diseases, such as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single vesicle release event (quantal size) and the kinetics of exocytosis. Complementary metal-oxide-semiconductor (CMOS) technologies enable the design and fabrication of devices with hundreds or thousands of planar electrodes and amplifiers integrated on the same chip, offering high throughput measurement of exocytosis from living cells. In this dissertation, the development and application of CMOC IC devices with surface modified structures for electrochemical characterization of live cell exocytosis are introduced. In chapter 2, a surface modified CMOS integrated circuit (IC) is demonstrated for highly parallel amperometry measurement of live chromaffin cells. The surface modified structures with SU-8 microwells fabricated on the chip surface solved the two major issues for on-chip single cell measurement devices, the reliability and the single cell targeting efficiency. The surface modified CMOC IC was able to reliably measure 10-30 cells per time per chip with low noise levels, which was a significant increase in efficiency compared to conventional carbon fiber microelectrode measurement. In chapter 3, the surface modified CMOS IC was used to investigate the working mechanisms of the antidepressant drugs bupropion and citalopram. Bupropion was found to potentiate the quantal size and citalopram to increase the release frequency by increasing the readily releasable pool (RRP) size. In chapter 4, a bidirectional-current measurement CMOS IC was designed to enable on-chip cyclic voltammetry (CV) measurement. The new design was capable of measuring current within the range of ±1.5 nA at 10 kS/s. Finally, an improved CMOS IC for CV measurement is presented in chapter 5. The devices consumed less area for each detector and a sign binary output was implemented to identify the polarity of the output current. The devices were validated with on-chip dopamine injection test and potassium ferricyanide CV measurement."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"efb792ef-f24e-48ab-99c2-157c61f46590\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-05-30</PublicationDate> <DOI>https://doi.org/10.7298/rfp3-fd68</DOI> <Authors> <Author> <DisplayName>Huang, Meng</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Chromaffin Cells</Keyword> <Keyword>Neurotransmitter Release</Keyword> <Keyword>Biophysics</Keyword> <Keyword>biosensor</Keyword> <Keyword>amperometry</Keyword> <Keyword>CMOS</Keyword> <Keyword>Materials Science</Keyword> <Keyword>Integrated Circuit</Keyword> <Abstract>Neurotransmitters are released to the extracellular space in packages by the fusion of vesicles with the cell membrane, a process known as exocytosis. Modulation of this process is a key target for the treatment of neurogenerative diseases, such as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single vesicle release event (quantal size) and the kinetics of exocytosis. Complementary metal-oxide-semiconductor (CMOS) technologies enable the design and fabrication of devices with hundreds or thousands of planar electrodes and amplifiers integrated on the same chip, offering high throughput measurement of exocytosis from living cells. In this dissertation, the development and application of CMOC IC devices with surface modified structures for electrochemical characterization of live cell exocytosis are introduced. In chapter 2, a surface modified CMOS integrated circuit (IC) is demonstrated for highly parallel amperometry measurement of live chromaffin cells. The surface modified structures with SU-8 microwells fabricated on the chip surface solved the two major issues for on-chip single cell measurement devices, the reliability and the single cell targeting efficiency. The surface modified CMOC IC was able to reliably measure 10-30 cells per time per chip with low noise levels, which was a significant increase in efficiency compared to conventional carbon fiber microelectrode measurement. In chapter 3, the surface modified CMOS IC was used to investigate the working mechanisms of the antidepressant drugs bupropion and citalopram. Bupropion was found to potentiate the quantal size and citalopram to increase the release frequency by increasing the readily releasable pool (RRP) size. In chapter 4, a bidirectional-current measurement CMOS IC was designed to enable on-chip cyclic voltammetry (CV) measurement. The new design was capable of measuring current within the range of ±1.5 nA at 10 kS/s. Finally, an improved CMOS IC for CV measurement is presented in chapter 5. The devices consumed less area for each detector and a sign binary output was implemented to identify the polarity of the output current. The devices were validated with on-chip dopamine injection test and potassium ferricyanide CV measurement.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Huang, Meng"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Van Dover, Robert B."],"dc:contributor.committeemember":["Lindau, Manfred","Ma, Minglin"],"dc:creator":["Huang, Meng"],"dc:date.accessioned":["2019-10-15T15:28:52Z"],"dc:date.available":["2021-06-05T06:00:31Z"],"dc:date.issued":["2019-05-30"],"dc:description.abstract":["Neurotransmitters are released to the extracellular space in packages by the fusion of vesicles with the cell membrane, a process known as exocytosis. Modulation of this process is a key target for the treatment of neurogenerative diseases, such as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single vesicle release event (quantal size) and the kinetics of exocytosis. Complementary metal-oxide-semiconductor (CMOS) technologies enable the design and fabrication of devices with hundreds or thousands of planar electrodes and amplifiers integrated on the same chip, offering high throughput measurement of exocytosis from living cells. In this dissertation, the development and application of CMOC IC devices with surface modified structures for electrochemical characterization of live cell exocytosis are introduced. In chapter 2, a surface modified CMOS integrated circuit (IC) is demonstrated for highly parallel amperometry measurement of live chromaffin cells. The surface modified structures with SU-8 microwells fabricated on the chip surface solved the two major issues for on-chip single cell measurement devices, the reliability and the single cell targeting efficiency. The surface modified CMOC IC was able to reliably measure 10-30 cells per time per chip with low noise levels, which was a significant increase in efficiency compared to conventional carbon fiber microelectrode measurement. In chapter 3, the surface modified CMOS IC was used to investigate the working mechanisms of the antidepressant drugs bupropion and citalopram. Bupropion was found to potentiate the quantal size and citalopram to increase the release frequency by increasing the readily releasable pool (RRP) size. In chapter 4, a bidirectional-current measurement CMOS IC was designed to enable on-chip cyclic voltammetry (CV) measurement. The new design was capable of measuring current within the range of ±1.5 nA at 10 kS/s. Finally, an improved CMOS IC for CV measurement is presented in chapter 5. The devices consumed less area for each detector and a sign binary output was implemented to identify the polarity of the output current. The devices were validated with on-chip dopamine injection test and potassium ferricyanide CV measurement."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["11050251"],"dc:identifier.doi":["https://doi.org/10.7298/rfp3-fd68"],"dc:identifier.other":["ProQuest Submission ID: 11337","ProQuest Publication ID: 13856338"],"dc:identifier.uri":["https://hdl.handle.net/1813/67269"],"dc:language.iso":["en_US"],"dc:subject":["Chromaffin Cells","Neurotransmitter Release","Biophysics","biosensor","amperometry","CMOS","Materials Science","Integrated Circuit"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph.D., Materials Science and Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:20:35Z"}