{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/67363"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/67363","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Studies of Hotspot Characteristics in Hybrid X-Pinches with Different Inter-Electrode Gaps","abstract":"ABSTRACT The hybrid X-pinch configuration for pulsed power experiments consists of a fine wire strung between two solid electrodes, the x-ray burst from which is characterized by a single bright hotspot of soft X-rays under ideal circumstances. These ideal circumstances depend on a number of variables including the size of the gap between the electrodes and the material of the wire used in the test. Testing four different materials (Al, Ti, Mo, Ag) at gap distances ranging from 0.5 to 5.0 mm enabled some insight into the parameters needed to consistently produce a single hotspot. Shots at higher gap distances (≥ 2.0 mm) using the higher-Z materials (Mo, Ag) would produce more hotspots than shots at smaller gap distances (≤ 1.5 mm) with lower-Z materials (Al, Ti). There also appears to be a weak correlation between higher-Z materials and higher energy hotspots, though no such correlation appears for hotspot source size. Understanding the effects of gap distance and wire material on hotspot and X-ray production enables more precise use of the hybrid X-pinch as an X-ray source for spectroscopic studies or backlight imaging.","abstract_html":"ABSTRACT The hybrid X-pinch configuration for pulsed power experiments consists of a fine wire strung between two solid electrodes, the x-ray burst from which is characterized by a single bright hotspot of soft X-rays under ideal circumstances. These ideal circumstances depend on a number of variables including the size of the gap between the electrodes and the material of the wire used in the test. Testing four different materials (Al, Ti, Mo, Ag) at gap distances ranging from 0.5 to 5.0 mm enabled some insight into the parameters needed to consistently produce a single hotspot. Shots at higher gap distances (≥ 2.0 mm) using the higher-Z materials (Mo, Ag) would produce more hotspots than shots at smaller gap distances (≤ 1.5 mm) with lower-Z materials (Al, Ti). There also appears to be a weak correlation between higher-Z materials and higher energy hotspots, though no such correlation appears for hotspot source size. Understanding the effects of gap distance and wire material on hotspot and X-ray production enables more precise use of the hybrid X-pinch as an X-ray source for spectroscopic studies or backlight imaging.","abstract_has_math":false,"creators":["Musk, Jeffrey"],"institution":"Cornell University","degree_name":"M.S., Applied Physics","degree_level":"Master of Science","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Hammer, David A."],"committee_members":["Kusse, Bruce Raymond"],"year":2019,"date_issued":"2019-05-30","date_published":"2019-05-30","updated_at":"2026-11-19T03:20:35Z","subjects":["X-Pinch","Plasma physics","Hybrid X-Pinch"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/n6bw-3s79"],"render_values":[{"text":"https://doi.org/10.7298/n6bw-3s79","href":"https://doi.org/10.7298/n6bw-3s79","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050345"],"render_values":[{"text":"11050345","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10503","ProQuest Publication ID: 13879849"],"render_values":[{"text":"ProQuest Submission ID: 10503","href":null,"code":true},{"text":"ProQuest Publication ID: 13879849","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/67363","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/67363","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F67363","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Hammer, David A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kusse, Bruce Raymond"]},{"key":"dc:creator","label":"Author","values":["Musk, Jeffrey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-10-15T15:30:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-10-15T15:30:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-05-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["X-Pinch","Plasma physics","Hybrid X-Pinch"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050345"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/n6bw-3s79"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10503","ProQuest Publication ID: 13879849"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/67363"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2d0ace78-7eb0-40fa-919a-9b0449031f28\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Studies of Hotspot Characteristics in Hybrid X-Pinches with Different Inter-Electrode Gaps</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-05-30</PublicationDate> <DOI>https://doi.org/10.7298/n6bw-3s79</DOI> <Authors> <Author> <DisplayName>Musk, Jeffrey</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>X-Pinch</Keyword> <Keyword>Plasma physics</Keyword> <Keyword>Hybrid X-Pinch</Keyword> <Abstract>ABSTRACT The hybrid X-pinch configuration for pulsed power experiments consists of a fine wire strung between two solid electrodes, the x-ray burst from which is characterized by a single bright hotspot of soft X-rays under ideal circumstances. These ideal circumstances depend on a number of variables including the size of the gap between the electrodes and the material of the wire used in the test. Testing four different materials (Al, Ti, Mo, Ag) at gap distances ranging from 0.5 to 5.0 mm enabled some insight into the parameters needed to consistently produce a single hotspot. Shots at higher gap distances (≥ 2.0 mm) using the higher-Z materials (Mo, Ag) would produce more hotspots than shots at smaller gap distances (≤ 1.5 mm) with lower-Z materials (Al, Ti). There also appears to be a weak correlation between higher-Z materials and higher energy hotspots, though no such correlation appears for hotspot source size. Understanding the effects of gap distance and wire material on hotspot and X-ray production enables more precise use of the hybrid X-pinch as an X-ray source for spectroscopic studies or backlight imaging.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Musk, Jeffrey"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["ABSTRACT The hybrid X-pinch configuration for pulsed power experiments consists of a fine wire strung between two solid electrodes, the x-ray burst from which is characterized by a single bright hotspot of soft X-rays under ideal circumstances. These ideal circumstances depend on a number of variables including the size of the gap between the electrodes and the material of the wire used in the test. Testing four different materials (Al, Ti, Mo, Ag) at gap distances ranging from 0.5 to 5.0 mm enabled some insight into the parameters needed to consistently produce a single hotspot. Shots at higher gap distances (≥ 2.0 mm) using the higher-Z materials (Mo, Ag) would produce more hotspots than shots at smaller gap distances (≤ 1.5 mm) with lower-Z materials (Al, Ti). There also appears to be a weak correlation between higher-Z materials and higher energy hotspots, though no such correlation appears for hotspot source size. Understanding the effects of gap distance and wire material on hotspot and X-ray production enables more precise use of the hybrid X-pinch as an X-ray source for spectroscopic studies or backlight imaging."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Studies of Hotspot Characteristics in Hybrid X-Pinches with Different Inter-Electrode Gaps"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2d0ace78-7eb0-40fa-919a-9b0449031f28\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Studies of Hotspot Characteristics in Hybrid X-Pinches with Different Inter-Electrode Gaps</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-05-30</PublicationDate> <DOI>https://doi.org/10.7298/n6bw-3s79</DOI> <Authors> <Author> <DisplayName>Musk, Jeffrey</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>X-Pinch</Keyword> <Keyword>Plasma physics</Keyword> <Keyword>Hybrid X-Pinch</Keyword> <Abstract>ABSTRACT The hybrid X-pinch configuration for pulsed power experiments consists of a fine wire strung between two solid electrodes, the x-ray burst from which is characterized by a single bright hotspot of soft X-rays under ideal circumstances. These ideal circumstances depend on a number of variables including the size of the gap between the electrodes and the material of the wire used in the test. Testing four different materials (Al, Ti, Mo, Ag) at gap distances ranging from 0.5 to 5.0 mm enabled some insight into the parameters needed to consistently produce a single hotspot. Shots at higher gap distances (≥ 2.0 mm) using the higher-Z materials (Mo, Ag) would produce more hotspots than shots at smaller gap distances (≤ 1.5 mm) with lower-Z materials (Al, Ti). There also appears to be a weak correlation between higher-Z materials and higher energy hotspots, though no such correlation appears for hotspot source size. Understanding the effects of gap distance and wire material on hotspot and X-ray production enables more precise use of the hybrid X-pinch as an X-ray source for spectroscopic studies or backlight imaging.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Musk, Jeffrey"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Hammer, David A."],"dc:contributor.committeemember":["Kusse, Bruce Raymond"],"dc:creator":["Musk, Jeffrey"],"dc:date.accessioned":["2019-10-15T15:30:26Z"],"dc:date.available":["2019-10-15T15:30:26Z"],"dc:date.issued":["2019-05-30"],"dc:description.abstract":["ABSTRACT The hybrid X-pinch configuration for pulsed power experiments consists of a fine wire strung between two solid electrodes, the x-ray burst from which is characterized by a single bright hotspot of soft X-rays under ideal circumstances. These ideal circumstances depend on a number of variables including the size of the gap between the electrodes and the material of the wire used in the test. Testing four different materials (Al, Ti, Mo, Ag) at gap distances ranging from 0.5 to 5.0 mm enabled some insight into the parameters needed to consistently produce a single hotspot. Shots at higher gap distances (≥ 2.0 mm) using the higher-Z materials (Mo, Ag) would produce more hotspots than shots at smaller gap distances (≤ 1.5 mm) with lower-Z materials (Al, Ti). There also appears to be a weak correlation between higher-Z materials and higher energy hotspots, though no such correlation appears for hotspot source size. Understanding the effects of gap distance and wire material on hotspot and X-ray production enables more precise use of the hybrid X-pinch as an X-ray source for spectroscopic studies or backlight imaging."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["11050345"],"dc:identifier.doi":["https://doi.org/10.7298/n6bw-3s79"],"dc:identifier.other":["ProQuest Submission ID: 10503","ProQuest Publication ID: 13879849"],"dc:identifier.uri":["https://hdl.handle.net/1813/67363"],"dc:language.iso":["en_US"],"dc:subject":["X-Pinch","Plasma physics","Hybrid X-Pinch"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Studies of Hotspot Characteristics in Hybrid X-Pinches with Different Inter-Electrode Gaps"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Applied Physics"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:20:35Z"}