{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/67504"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/67504","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Development of point-of-care diagnostic technologies for global and mental health","abstract":"Access to diagnostic testing and screening technologies helps to improve patient care by enabling early treatment and monitoring of patient condition. Most of these technologies, however, rely on laboratory infrastructure and are expensive and time-consuming. In many limited-resource settings, these challenges are too great to overcome, preventing patient access to early diagnosis and screening. Point-of-care diagnostic technologies are designed to fill this need, providing low-cost, easy-to-use, and rapid testing. Lateral flow assays (LFAs) represent a simple platform for biomarker-based point-of-care diagnostics with very low cost and a rapid result. Antigen-antibody binding forms the basis of these tests, with labeled antibodies or proteins typically providing an optical signal that can either be seen by eye or analyzed using imaging devices. Microfluidic assays are another form of biomarker analysis that can be designed to incorporate more complex assays with more steps than a traditional LFA. In this work, we describe our efforts to develop novel and improved immunoassays for use at the point of care based on LFA and microfluidic technologies. The first three chapters of this dissertation describe our work on three different applications of lateral flow technology. We will first discuss our improvements to the detection range of an LFA through periodic measurement of the developing signal and kinetic analysis of the result. This work demonstrated our ability to overcome the high-dose hook effect without altering the LFA or the steps required by the user. Next, we present our point-of-care system for determination of folate status in serum. This technology provides a method for measuring folate concentration in serum without the use of complex technology. Our third lateral flow technology is an LFA to measure cortisol concentration in saliva. This LFA was validated in saliva samples from a human study that analyzed participant alertness and cortisol levels. Our final work describes the design of a microfluidic system for improved sensitivity in measurement of cortisol concentration in saliva. This system incorporates sample collection, filtration, treatment, and transfer to the microfluidic assay. An all-in-one device interacts with a disposable cassette to pump saliva into the microfluidic chip and provide a result.","abstract_html":"Access to diagnostic testing and screening technologies helps to improve patient care by enabling early treatment and monitoring of patient condition. Most of these technologies, however, rely on laboratory infrastructure and are expensive and time-consuming. In many limited-resource settings, these challenges are too great to overcome, preventing patient access to early diagnosis and screening. Point-of-care diagnostic technologies are designed to fill this need, providing low-cost, easy-to-use, and rapid testing. Lateral flow assays (LFAs) represent a simple platform for biomarker-based point-of-care diagnostics with very low cost and a rapid result. Antigen-antibody binding forms the basis of these tests, with labeled antibodies or proteins typically providing an optical signal that can either be seen by eye or analyzed using imaging devices. Microfluidic assays are another form of biomarker analysis that can be designed to incorporate more complex assays with more steps than a traditional LFA. In this work, we describe our efforts to develop novel and improved immunoassays for use at the point of care based on LFA and microfluidic technologies. The first three chapters of this dissertation describe our work on three different applications of lateral flow technology. We will first discuss our improvements to the detection range of an LFA through periodic measurement of the developing signal and kinetic analysis of the result. This work demonstrated our ability to overcome the high-dose hook effect without altering the LFA or the steps required by the user. Next, we present our point-of-care system for determination of folate status in serum. This technology provides a method for measuring folate concentration in serum without the use of complex technology. Our third lateral flow technology is an LFA to measure cortisol concentration in saliva. This LFA was validated in saliva samples from a human study that analyzed participant alertness and cortisol levels. Our final work describes the design of a microfluidic system for improved sensitivity in measurement of cortisol concentration in saliva. This system incorporates sample collection, filtration, treatment, and transfer to the microfluidic assay. An all-in-one device interacts with a disposable cassette to pump saliva into the microfluidic chip and provide a result.","abstract_has_math":false,"creators":["Rey, Elizabeth Grace"],"institution":"Cornell University","degree_name":"Ph.D., Mechanical Engineering","degree_level":"Doctor of Philosophy","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Erickson, David"],"committee_members":["Mehta, Julia Leigh","Singh, Ankur"],"year":2019,"date_issued":"2019-08-30","date_published":"2019-08-30","updated_at":"2026-11-19T03:20:50Z","subjects":["Biomarker","Lateral flow assay","Nutrition","stress","Mechanical engineering","Global Health","point-of-care","microfluidics","Biomedical engineering"],"languages":["en_US"],"rights":["Attribution-NoDerivs 2.0 Generic"],"rights_urls":["https://creativecommons.org/licenses/by-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/qanw-sb41"],"render_values":[{"text":"https://doi.org/10.7298/qanw-sb41","href":"https://doi.org/10.7298/qanw-sb41","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050486"],"render_values":[{"text":"11050486","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11609","ProQuest Publication ID: 22588600"],"render_values":[{"text":"ProQuest Submission ID: 11609","href":null,"code":true},{"text":"ProQuest Publication ID: 22588600","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/67504","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/67504","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F67504","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Erickson, David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mehta, Julia Leigh","Singh, Ankur"]},{"key":"dc:creator","label":"Author","values":["Rey, Elizabeth Grace"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-10-15T16:47:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-08-29T06:00:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-08-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomarker","Lateral flow assay","Nutrition","stress","Mechanical engineering","Global Health","point-of-care","microfluidics","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivs 2.0 Generic"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050486"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/qanw-sb41"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11609","ProQuest Publication ID: 22588600"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/67504"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"35c91431-4253-421d-9611-89147d8593e4\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development of point-of-care diagnostic technologies for global and mental health</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-08-30</PublicationDate> <DOI>https://doi.org/10.7298/qanw-sb41</DOI> <Authors> <Author> <DisplayName>Rey, Elizabeth Grace</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nd/4.0/</License> <Keyword>Biomarker</Keyword> <Keyword>Lateral flow assay</Keyword> <Keyword>Nutrition</Keyword> <Keyword>stress</Keyword> <Keyword>Mechanical engineering</Keyword> <Keyword>Global Health</Keyword> <Keyword>point-of-care</Keyword> <Keyword>microfluidics</Keyword> <Keyword>Biomedical engineering</Keyword> <Abstract>Access to diagnostic testing and screening technologies helps to improve patient care by enabling early treatment and monitoring of patient condition. Most of these technologies, however, rely on laboratory infrastructure and are expensive and time-consuming. In many limited-resource settings, these challenges are too great to overcome, preventing patient access to early diagnosis and screening. Point-of-care diagnostic technologies are designed to fill this need, providing low-cost, easy-to-use, and rapid testing. Lateral flow assays (LFAs) represent a simple platform for biomarker-based point-of-care diagnostics with very low cost and a rapid result. Antigen-antibody binding forms the basis of these tests, with labeled antibodies or proteins typically providing an optical signal that can either be seen by eye or analyzed using imaging devices. Microfluidic assays are another form of biomarker analysis that can be designed to incorporate more complex assays with more steps than a traditional LFA. In this work, we describe our efforts to develop novel and improved immunoassays for use at the point of care based on LFA and microfluidic technologies. The first three chapters of this dissertation describe our work on three different applications of lateral flow technology. We will first discuss our improvements to the detection range of an LFA through periodic measurement of the developing signal and kinetic analysis of the result. This work demonstrated our ability to overcome the high-dose hook effect without altering the LFA or the steps required by the user. Next, we present our point-of-care system for determination of folate status in serum. This technology provides a method for measuring folate concentration in serum without the use of complex technology. Our third lateral flow technology is an LFA to measure cortisol concentration in saliva. This LFA was validated in saliva samples from a human study that analyzed participant alertness and cortisol levels. Our final work describes the design of a microfluidic system for improved sensitivity in measurement of cortisol concentration in saliva. This system incorporates sample collection, filtration, treatment, and transfer to the microfluidic assay. An all-in-one device interacts with a disposable cassette to pump saliva into the microfluidic chip and provide a result.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Rey, Elizabeth Grace"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Access to diagnostic testing and screening technologies helps to improve patient care by enabling early treatment and monitoring of patient condition. Most of these technologies, however, rely on laboratory infrastructure and are expensive and time-consuming. In many limited-resource settings, these challenges are too great to overcome, preventing patient access to early diagnosis and screening. Point-of-care diagnostic technologies are designed to fill this need, providing low-cost, easy-to-use, and rapid testing. Lateral flow assays (LFAs) represent a simple platform for biomarker-based point-of-care diagnostics with very low cost and a rapid result. Antigen-antibody binding forms the basis of these tests, with labeled antibodies or proteins typically providing an optical signal that can either be seen by eye or analyzed using imaging devices. Microfluidic assays are another form of biomarker analysis that can be designed to incorporate more complex assays with more steps than a traditional LFA. In this work, we describe our efforts to develop novel and improved immunoassays for use at the point of care based on LFA and microfluidic technologies. The first three chapters of this dissertation describe our work on three different applications of lateral flow technology. We will first discuss our improvements to the detection range of an LFA through periodic measurement of the developing signal and kinetic analysis of the result. This work demonstrated our ability to overcome the high-dose hook effect without altering the LFA or the steps required by the user. Next, we present our point-of-care system for determination of folate status in serum. This technology provides a method for measuring folate concentration in serum without the use of complex technology. Our third lateral flow technology is an LFA to measure cortisol concentration in saliva. This LFA was validated in saliva samples from a human study that analyzed participant alertness and cortisol levels. Our final work describes the design of a microfluidic system for improved sensitivity in measurement of cortisol concentration in saliva. This system incorporates sample collection, filtration, treatment, and transfer to the microfluidic assay. An all-in-one device interacts with a disposable cassette to pump saliva into the microfluidic chip and provide a result."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Development of point-of-care diagnostic technologies for global and mental health"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"35c91431-4253-421d-9611-89147d8593e4\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Development of point-of-care diagnostic technologies for global and mental health</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-08-30</PublicationDate> <DOI>https://doi.org/10.7298/qanw-sb41</DOI> <Authors> <Author> <DisplayName>Rey, Elizabeth Grace</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nd/4.0/</License> <Keyword>Biomarker</Keyword> <Keyword>Lateral flow assay</Keyword> <Keyword>Nutrition</Keyword> <Keyword>stress</Keyword> <Keyword>Mechanical engineering</Keyword> <Keyword>Global Health</Keyword> <Keyword>point-of-care</Keyword> <Keyword>microfluidics</Keyword> <Keyword>Biomedical engineering</Keyword> <Abstract>Access to diagnostic testing and screening technologies helps to improve patient care by enabling early treatment and monitoring of patient condition. Most of these technologies, however, rely on laboratory infrastructure and are expensive and time-consuming. In many limited-resource settings, these challenges are too great to overcome, preventing patient access to early diagnosis and screening. Point-of-care diagnostic technologies are designed to fill this need, providing low-cost, easy-to-use, and rapid testing. Lateral flow assays (LFAs) represent a simple platform for biomarker-based point-of-care diagnostics with very low cost and a rapid result. Antigen-antibody binding forms the basis of these tests, with labeled antibodies or proteins typically providing an optical signal that can either be seen by eye or analyzed using imaging devices. Microfluidic assays are another form of biomarker analysis that can be designed to incorporate more complex assays with more steps than a traditional LFA. In this work, we describe our efforts to develop novel and improved immunoassays for use at the point of care based on LFA and microfluidic technologies. The first three chapters of this dissertation describe our work on three different applications of lateral flow technology. We will first discuss our improvements to the detection range of an LFA through periodic measurement of the developing signal and kinetic analysis of the result. This work demonstrated our ability to overcome the high-dose hook effect without altering the LFA or the steps required by the user. Next, we present our point-of-care system for determination of folate status in serum. This technology provides a method for measuring folate concentration in serum without the use of complex technology. Our third lateral flow technology is an LFA to measure cortisol concentration in saliva. This LFA was validated in saliva samples from a human study that analyzed participant alertness and cortisol levels. Our final work describes the design of a microfluidic system for improved sensitivity in measurement of cortisol concentration in saliva. This system incorporates sample collection, filtration, treatment, and transfer to the microfluidic assay. An all-in-one device interacts with a disposable cassette to pump saliva into the microfluidic chip and provide a result.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Rey, Elizabeth Grace"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Erickson, David"],"dc:contributor.committeemember":["Mehta, Julia Leigh","Singh, Ankur"],"dc:creator":["Rey, Elizabeth Grace"],"dc:date.accessioned":["2019-10-15T16:47:19Z"],"dc:date.available":["2020-08-29T06:00:28Z"],"dc:date.issued":["2019-08-30"],"dc:description.abstract":["Access to diagnostic testing and screening technologies helps to improve patient care by enabling early treatment and monitoring of patient condition. Most of these technologies, however, rely on laboratory infrastructure and are expensive and time-consuming. In many limited-resource settings, these challenges are too great to overcome, preventing patient access to early diagnosis and screening. Point-of-care diagnostic technologies are designed to fill this need, providing low-cost, easy-to-use, and rapid testing. Lateral flow assays (LFAs) represent a simple platform for biomarker-based point-of-care diagnostics with very low cost and a rapid result. Antigen-antibody binding forms the basis of these tests, with labeled antibodies or proteins typically providing an optical signal that can either be seen by eye or analyzed using imaging devices. Microfluidic assays are another form of biomarker analysis that can be designed to incorporate more complex assays with more steps than a traditional LFA. In this work, we describe our efforts to develop novel and improved immunoassays for use at the point of care based on LFA and microfluidic technologies. The first three chapters of this dissertation describe our work on three different applications of lateral flow technology. We will first discuss our improvements to the detection range of an LFA through periodic measurement of the developing signal and kinetic analysis of the result. This work demonstrated our ability to overcome the high-dose hook effect without altering the LFA or the steps required by the user. Next, we present our point-of-care system for determination of folate status in serum. This technology provides a method for measuring folate concentration in serum without the use of complex technology. Our third lateral flow technology is an LFA to measure cortisol concentration in saliva. This LFA was validated in saliva samples from a human study that analyzed participant alertness and cortisol levels. Our final work describes the design of a microfluidic system for improved sensitivity in measurement of cortisol concentration in saliva. This system incorporates sample collection, filtration, treatment, and transfer to the microfluidic assay. An all-in-one device interacts with a disposable cassette to pump saliva into the microfluidic chip and provide a result."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["11050486"],"dc:identifier.doi":["https://doi.org/10.7298/qanw-sb41"],"dc:identifier.other":["ProQuest Submission ID: 11609","ProQuest Publication ID: 22588600"],"dc:identifier.uri":["https://hdl.handle.net/1813/67504"],"dc:language.iso":["en_US"],"dc:rights":["Attribution-NoDerivs 2.0 Generic"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nd/4.0/"],"dc:subject":["Biomarker","Lateral flow assay","Nutrition","stress","Mechanical engineering","Global Health","point-of-care","microfluidics","Biomedical engineering"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Development of point-of-care diagnostic technologies for global and mental health"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph.D., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:20:50Z"}