{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/67552"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/67552","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Towards the Development of Organic Electrochemical Devices for Enveloped Virus Detection","abstract":"Viral infections induced by enveloped viruses have been a major public health concern for decades. In order to initiate timely antiviral therapy and reduce human mortality during a virus outbreak, a sensitive viral diagnostic technique that can rapidly detect and identify enveloped viruses is necessary. The supported lipid bilayer (SLB) is a well-established representative of a cell membrane that mimics the outer biological surface of a host cell. It is commonly formed on electrically inert, planar, silica-based surfaces and have been used with great effect to characterize virus-host interactions. However, these studies require the virus to be fluorescently labeled prior to study. Therefore, we proposed to form these biomimetic SLBs on PEDOT:PSS, a conductive polymer support, that the charged viral genome can interact with upon fusion, resulting in an electrical readout. Challenges lie in constructing SLBs on PEDOT:PSS due to both electrostatic repulsion between the polymer and charged species in the cell membrane and the swollen polymers unfavorable surface smoothness that can prevent membrane vesicles from fusing into a planar geometry. Various stimuli were explored to successfully induce bilayer formation on the polymer surface, which includes divalent cations, charged liposomes, pegylated cushions, and external macromolecules. Furthermore, because this polymer is transparent, we could still carry out single virion fusion using fluorescence microscopy to corroborate the ability to successfully test the electrical sensing in the future. This critical work demonstrates the potential for this platform to become a new kinds of viral detection device.","abstract_html":"Viral infections induced by enveloped viruses have been a major public health concern for decades. In order to initiate timely antiviral therapy and reduce human mortality during a virus outbreak, a sensitive viral diagnostic technique that can rapidly detect and identify enveloped viruses is necessary. The supported lipid bilayer (SLB) is a well-established representative of a cell membrane that mimics the outer biological surface of a host cell. It is commonly formed on electrically inert, planar, silica-based surfaces and have been used with great effect to characterize virus-host interactions. However, these studies require the virus to be fluorescently labeled prior to study. Therefore, we proposed to form these biomimetic SLBs on PEDOT:PSS, a conductive polymer support, that the charged viral genome can interact with upon fusion, resulting in an electrical readout. Challenges lie in constructing SLBs on PEDOT:PSS due to both electrostatic repulsion between the polymer and charged species in the cell membrane and the swollen polymers unfavorable surface smoothness that can prevent membrane vesicles from fusing into a planar geometry. Various stimuli were explored to successfully induce bilayer formation on the polymer surface, which includes divalent cations, charged liposomes, pegylated cushions, and external macromolecules. Furthermore, because this polymer is transparent, we could still carry out single virion fusion using fluorescence microscopy to corroborate the ability to successfully test the electrical sensing in the future. This critical work demonstrates the potential for this platform to become a new kinds of viral detection device.","abstract_has_math":false,"creators":["Xu, Cheyan"],"institution":"Cornell University","degree_name":"M.S., Chemical Engineering","degree_level":"Master of Science","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Daniel, Susan"],"committee_members":["Ober, Christopher Kemper"],"year":2019,"date_issued":"2019-08-30","date_published":"2019-08-30","updated_at":"2026-11-19T03:20:50Z","subjects":["Chemical engineering","Supported lipid bilayer","Materials Science","organic electrochemical device","PEDOT:PSS","SLB","viral sensor","Bioengineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/73fh-n394"],"render_values":[{"text":"https://doi.org/10.7298/73fh-n394","href":"https://doi.org/10.7298/73fh-n394","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050535"],"render_values":[{"text":"11050535","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10641","ProQuest Publication ID: 22587751"],"render_values":[{"text":"ProQuest Submission ID: 10641","href":null,"code":true},{"text":"ProQuest Publication ID: 22587751","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/67552","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/67552","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F67552","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Daniel, Susan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ober, Christopher Kemper"]},{"key":"dc:creator","label":"Author","values":["Xu, Cheyan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-10-15T16:48:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-02-29T07:00:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-08-30"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Chemical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical engineering","Supported lipid bilayer","Materials Science","organic electrochemical device","PEDOT:PSS","SLB","viral sensor","Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["11050535"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/73fh-n394"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10641","ProQuest Publication ID: 22587751"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/67552"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"13e78371-66dd-4525-9b69-607099690b55\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Towards the Development of Organic Electrochemical Devices for Enveloped Virus Detection</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-08-30</PublicationDate> <DOI>https://doi.org/10.7298/73fh-n394</DOI> <Authors> <Author> <DisplayName>Xu, Cheyan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Chemical engineering</Keyword> <Keyword>Supported lipid bilayer</Keyword> <Keyword>Materials Science</Keyword> <Keyword>organic electrochemical device</Keyword> <Keyword>PEDOT:PSS</Keyword> <Keyword>SLB</Keyword> <Keyword>viral sensor</Keyword> <Keyword>Bioengineering</Keyword> <Abstract>Viral infections induced by enveloped viruses have been a major public health concern for decades. In order to initiate timely antiviral therapy and reduce human mortality during a virus outbreak, a sensitive viral diagnostic technique that can rapidly detect and identify enveloped viruses is necessary. The supported lipid bilayer (SLB) is a well-established representative of a cell membrane that mimics the outer biological surface of a host cell. It is commonly formed on electrically inert, planar, silica-based surfaces and have been used with great effect to characterize virus-host interactions. However, these studies require the virus to be fluorescently labeled prior to study. Therefore, we proposed to form these biomimetic SLBs on PEDOT:PSS, a conductive polymer support, that the charged viral genome can interact with upon fusion, resulting in an electrical readout. Challenges lie in constructing SLBs on PEDOT:PSS due to both electrostatic repulsion between the polymer and charged species in the cell membrane and the swollen polymers unfavorable surface smoothness that can prevent membrane vesicles from fusing into a planar geometry. Various stimuli were explored to successfully induce bilayer formation on the polymer surface, which includes divalent cations, charged liposomes, pegylated cushions, and external macromolecules. Furthermore, because this polymer is transparent, we could still carry out single virion fusion using fluorescence microscopy to corroborate the ability to successfully test the electrical sensing in the future. This critical work demonstrates the potential for this platform to become a new kinds of viral detection device.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Xu, Cheyan"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description.abstract","label":"Abstract","values":["Viral infections induced by enveloped viruses have been a major public health concern for decades. In order to initiate timely antiviral therapy and reduce human mortality during a virus outbreak, a sensitive viral diagnostic technique that can rapidly detect and identify enveloped viruses is necessary. The supported lipid bilayer (SLB) is a well-established representative of a cell membrane that mimics the outer biological surface of a host cell. It is commonly formed on electrically inert, planar, silica-based surfaces and have been used with great effect to characterize virus-host interactions. However, these studies require the virus to be fluorescently labeled prior to study. Therefore, we proposed to form these biomimetic SLBs on PEDOT:PSS, a conductive polymer support, that the charged viral genome can interact with upon fusion, resulting in an electrical readout. Challenges lie in constructing SLBs on PEDOT:PSS due to both electrostatic repulsion between the polymer and charged species in the cell membrane and the swollen polymers unfavorable surface smoothness that can prevent membrane vesicles from fusing into a planar geometry. Various stimuli were explored to successfully induce bilayer formation on the polymer surface, which includes divalent cations, charged liposomes, pegylated cushions, and external macromolecules. Furthermore, because this polymer is transparent, we could still carry out single virion fusion using fluorescence microscopy to corroborate the ability to successfully test the electrical sensing in the future. This critical work demonstrates the potential for this platform to become a new kinds of viral detection device."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Towards the Development of Organic Electrochemical Devices for Enveloped Virus Detection"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"13e78371-66dd-4525-9b69-607099690b55\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en_US</Language> <Title>Towards the Development of Organic Electrochemical Devices for Enveloped Virus Detection</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-08-30</PublicationDate> <DOI>https://doi.org/10.7298/73fh-n394</DOI> <Authors> <Author> <DisplayName>Xu, Cheyan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Chemical engineering</Keyword> <Keyword>Supported lipid bilayer</Keyword> <Keyword>Materials Science</Keyword> <Keyword>organic electrochemical device</Keyword> <Keyword>PEDOT:PSS</Keyword> <Keyword>SLB</Keyword> <Keyword>viral sensor</Keyword> <Keyword>Bioengineering</Keyword> <Abstract>Viral infections induced by enveloped viruses have been a major public health concern for decades. In order to initiate timely antiviral therapy and reduce human mortality during a virus outbreak, a sensitive viral diagnostic technique that can rapidly detect and identify enveloped viruses is necessary. The supported lipid bilayer (SLB) is a well-established representative of a cell membrane that mimics the outer biological surface of a host cell. It is commonly formed on electrically inert, planar, silica-based surfaces and have been used with great effect to characterize virus-host interactions. However, these studies require the virus to be fluorescently labeled prior to study. Therefore, we proposed to form these biomimetic SLBs on PEDOT:PSS, a conductive polymer support, that the charged viral genome can interact with upon fusion, resulting in an electrical readout. Challenges lie in constructing SLBs on PEDOT:PSS due to both electrostatic repulsion between the polymer and charged species in the cell membrane and the swollen polymers unfavorable surface smoothness that can prevent membrane vesicles from fusing into a planar geometry. Various stimuli were explored to successfully induce bilayer formation on the polymer surface, which includes divalent cations, charged liposomes, pegylated cushions, and external macromolecules. Furthermore, because this polymer is transparent, we could still carry out single virion fusion using fluorescence microscopy to corroborate the ability to successfully test the electrical sensing in the future. This critical work demonstrates the potential for this platform to become a new kinds of viral detection device.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Xu, Cheyan"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Daniel, Susan"],"dc:contributor.committeemember":["Ober, Christopher Kemper"],"dc:creator":["Xu, Cheyan"],"dc:date.accessioned":["2019-10-15T16:48:00Z"],"dc:date.available":["2020-02-29T07:00:29Z"],"dc:date.issued":["2019-08-30"],"dc:description.abstract":["Viral infections induced by enveloped viruses have been a major public health concern for decades. In order to initiate timely antiviral therapy and reduce human mortality during a virus outbreak, a sensitive viral diagnostic technique that can rapidly detect and identify enveloped viruses is necessary. The supported lipid bilayer (SLB) is a well-established representative of a cell membrane that mimics the outer biological surface of a host cell. It is commonly formed on electrically inert, planar, silica-based surfaces and have been used with great effect to characterize virus-host interactions. However, these studies require the virus to be fluorescently labeled prior to study. Therefore, we proposed to form these biomimetic SLBs on PEDOT:PSS, a conductive polymer support, that the charged viral genome can interact with upon fusion, resulting in an electrical readout. Challenges lie in constructing SLBs on PEDOT:PSS due to both electrostatic repulsion between the polymer and charged species in the cell membrane and the swollen polymers unfavorable surface smoothness that can prevent membrane vesicles from fusing into a planar geometry. Various stimuli were explored to successfully induce bilayer formation on the polymer surface, which includes divalent cations, charged liposomes, pegylated cushions, and external macromolecules. Furthermore, because this polymer is transparent, we could still carry out single virion fusion using fluorescence microscopy to corroborate the ability to successfully test the electrical sensing in the future. This critical work demonstrates the potential for this platform to become a new kinds of viral detection device."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["11050535"],"dc:identifier.doi":["https://doi.org/10.7298/73fh-n394"],"dc:identifier.other":["ProQuest Submission ID: 10641","ProQuest Publication ID: 22587751"],"dc:identifier.uri":["https://hdl.handle.net/1813/67552"],"dc:language.iso":["en_US"],"dc:subject":["Chemical engineering","Supported lipid bilayer","Materials Science","organic electrochemical device","PEDOT:PSS","SLB","viral sensor","Bioengineering"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Towards the Development of Organic Electrochemical Devices for Enveloped Virus Detection"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Chemical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:20:50Z"}